Specifications
Input power requirements: 16.5 -18VAC, 20VA
Standbybattery: 12-voltbattery,7AH(NP7-12)rechargeable
gel-type,notsupplied
Temperature operating range: 32oto 120o F
Auxiliarypoweroutput: 12.5VDCregulated,500mA
Belloutput: Burglary/fireoutput,12.5VDC,500mA
Loop Response: 10 - 300mSec. (1 second when dialing)
Maximum loop resistance: Nottoexceed 300 Ohmson any
loop(doesnotincludeEOLresistor)
Transient and lightning protection: Lightningandsurge
protectiononallinput,powerandtelephonelines
Dimensions: 13"Hx 9"Wx3"D
Shipping weight: 10 lbs.
FCCregistrationnumber:4T2USA-24862-AL-E
Ringer Equivalence: 0.2B
Compliance:ULListed
Order Information
SP850: SP850controlpackagedwith EOLresistors,sparefuses
andmetalenclosure.
KP600F Keypad: Digital armingstation that allowsfullsystem
status. 7 separate LEDs provide system status. Backlit keys.
Comes with back box for surface mounting.
Dimensions:4.500”X4.510”X1.110”
KP600LKeypad: AlphanumericLCDarmingstationthatallows
fullsystem status fromoneor more convenient locations. 1line
of 16 character display zone status and alarm memory for each
zone; Ready and arm status LEDs included.
Dimensions:6.570”X4.670”X1.100”
DOB: Data Output Board. One DOB may be connected to a
SP850forspecial outputs.
Keypad Controlled User Functions
• Arming/Disarming
• Bypassing zones or zone groups
• System test
• Fouremergency24-hourprogrammablefunctions
• Duress
• Smokedetectorreset
• Chimefeature
• Settime/date
• FaultAnalysis: ACLoss,LowBattery,ZoneTrouble,Failure
toCommunicate
DigitalCommunicatorFeatures
• Splitreportinguptothree20-digittelephonenumberwith
threeseparateaccountnumbers
• Threeor four digit account numbers
• Opening/closingreportsupto8users
• Programmablereportingattempts
• Failuretocommunicateannunciationatkeypad
• Zonebypass,Testtimereporting
• Silent Knight4+2;standardpulsereportingformats
• ScanProFSKformats,300-baudsoftwareavailable
• Alarm,Trouble,Restoralreportsbyzone
• Remotelyshutdownnonpayingaccounts
• Remotehighspeedup/downloadingfromIBM-compatible
Programmable Software Features
• "Follower"zones
• 2Assignable outputs
• Opening/closingreports
• Automatictest reporttoany combinationof 3 phonenumbers
• Dynamiclowbattery/restoralreporting;programmable
reportingdelays
• Falsealarmshutdown
• Software delete of EOL resistors
• Callback security 1510TateBlvd.SE
Hickory,NC28603
Sales: 800.547.2556
TechnicalSupport: 800.800.2027
Sentrol, Inc. reserves the
righttochangespecifications
withoutnotice.