Troubleshooting alarms Volumetric Divider
"Calybra"
Via Lago di Tovel, 14 - 36015 Schio (VI) - Italy
Tel +39-045-8182511 Fax +39-0445-50090
\\Servcad\macchine\UT\2 Documenti\2.2 Istruzioni Operative
ALARM # 201
Workpiece counter sensor
always active
Dirty sensor or
reflection device
opposite the dirty
sensor
Thoroughly clean the sensor end and the reflection surface
of the device opposite the sensor
Machine restarted
several times after
automatic stop for lack
of dough
The machine must always work with the dough available in
the hopper
Reflection device
opposite the damaged
sensor
Check the reflective surface of the device
Selection of single pieces not in
conformity with the working
program (only for 'MEMORY
PACK')
Selecting double
divider
On machine with "MEMORY PACK" option, the position of
the lever that determines the type of single/double dividing
is not in conformity with the working program.
Sensor "S3" is
damaged or is unable
to read the relevant
cam (consisting of the
rod connected to the
dividing selection lever
Single/Double), or is
disconnected from the
connector, or its
connection to the PLC
is interrupted.
Check that the sensor is not physically damaged on its
outside;
Check that the sensor is securely locked in place and that
its distance from the rod connected to the Single/Double
Split Selection Lever is NOT more than 1 mm;
Check that the connector for the connection to the sensor is
well inserted and its ring nut is locked;
Check that on the PLC "A1.0" the led #12 located in the
area called "IN" on the PLC lights up following the approach
of a metal element to the end of the sensor.
To restore TEMPORARY operation, disconnect connector "J3"
and start manual mode, setting the dividing weight manually
by using the manual adjustment handwheel and positioning
the Single/Double dividing selection lever as desired.
Selection of double pieces not in
accordance with the work
program (only for 'MEMORY
PACK')
Selecting single divider
On machine with "MEMORY PACK" option, the position of
the lever that determines the type of single/double dividing
is not in conformity with the working program.
Sensor "S3" is damaged
or is always active when
it is activated by a
extraneous metallic
object or its holder has
loosened.
Check that the sensor holder "S3" is stable in its position
and that the sensor "S3" is locked in position.
Check, by rotating the single/double divider selection lever,
that the sensor is activated only with double divider,
adapting the sensing position of the sensor itself.
If the operation of adapting the reading of the sensor "S3" does
not solve the problem, to restore the TEMPORARY
operation, disconnect the connector "J3" and start the
manual mode, setting the weight of dividing manually by
acting on the handwheel manual adjustment and positioning
the lever for selecting dividing Single / Double as desired.