ARTRA Fire Protection CM90 Instruction manual

TECHNICAL DATA
TECHNICAL DATATECHNICAL DATA
TECHNICAL DATA
WIRELESS SMOKE
DETECTOR CM90
ARTRA Fire Protection, email
ARTRA Fire Protection, email ARTRA Fire Protection, email
ARTRA Fire Protection, email info@artra.co.id
[email protected], support technis
, support technis , support technis
, support technis http //www.artra.co.id/
http //www.artra.co.id/http //www.artra.co.id/
http //www.artra.co.id/
AR/DS/Doc-2010009 1 | P a g e
1.
1.1.
1.
INTRODUCTION
INTRODUCTIONINTRODUCTION
INTRODUCTION
Ultra low power consumption, photoelectric
smoke detector sensor. Can provide both
local alarm and alarm information can be quickly
transmitted to the relevant user terminal
through the internet platform. This smoke
alarm is designed to protect the property by
detecting, sensing, and sending out alarm
signals in advance.
Note
-This product can only detect smoke particle
and temperature
-This product is only intended to be pre-
warned and prevented when installed in the
installation
2.
2.2.
2. TECHNICAL DATA
TECHNICAL DATATECHNICAL DATA
TECHNICAL DATA
Type Product AR-WFA-CM-SD
Power Supply DC9V battery 6F22
Battery Life 10 Month
Sound Specification >85dB / 3m
Ambient Temperature -10°C ~ 55°C
Humidity 95% RH max (no condensation)
Standby current >30uA
Alarm current ≥35mA
Self test time 60s
Installation Ceilling
3.
3.3.
3. REASONABLE INSTALLATION LOCATION
REASONABLE INSTALLATION LOCATIONREASONABLE INSTALLATION LOCATION
REASONABLE INSTALLATION LOCATION
Near the stairwell.
If the corridor is more than 12 meters long, install it at both ends of the bedroom
corridor.
This product can be installed in each separate bedroom to ensure that sleepers are
awake when someone in the bedroom is asleep and the bedroom door is closed.
As shown in Figure 3, this product can be installed in every room except the bathroom,
kitchen and basement.
As shown in Figures 1 & 2, this product can be installed in all bedrooms.
As shown in Figure 4, this product should be installed in the center of the ceiling as
much as possible, but please be careful not to install it near the corners of the edge.

TECHNICAL DATA
TECHNICAL DATATECHNICAL DATA
TECHNICAL DATA
WIRELESS SMOKE
DETECTOR CM90
ARTRA Fire Protection, email
ARTRA Fire Protection, email ARTRA Fire Protection, email
ARTRA Fire Protection, email info@artra.co.id
[email protected], support technis
, support technis , support technis
, support technis http //www.artra.co.id/
http //www.artra.co.id/http //www.artra.co.id/
http //www.artra.co.id/
AR/DS/Doc-2010009 2 | P a g e
As shown in Figure 5, when installing on an inclined surface or a curved surface, make
sure that the product is not too close to the corner corners.
Figure 1&2 - Bedroom installation diagram Figure 3 – inter-floor installation diagram
Figure 4 – ceiling installation diagram Figure 5 – curved surface installation diagram

TECHNICAL DATA
TECHNICAL DATATECHNICAL DATA
TECHNICAL DATA
WIRELESS SMOKE
DETECTOR CM90
ARTRA Fire Protection, email
ARTRA Fire Protection, email ARTRA Fire Protection, email
ARTRA Fire Protection, email info@artra.co.id
[email protected], support technis
, support technis , support technis
, support technis http //www.artra.co.id/
http //www.artra.co.id/http //www.artra.co.id/
http //www.artra.co.id/
AR/DS/Doc-2010009 3 | P a g e
Please do not install a smoke alarm in a humid environment, such as a bathroom. Water vapor
enters the detection unit of the smoke alarm, causing false alarms and malfunctions. Make
sure the smoke alarm is at least 3 meters away from the humid environment.
Do not install this product in a place where there may be a lot of dust. Dust may enter the
detection unit, causing false alarms.
Do not install this product in a place with high air circulation. Such as the air conditioner.
Strong air flow will blow away the smoke, causing the alarm to fail.
Do not install this product in places where air circulation is too weak, such as the roof. The
non-flowing air can hinder the spread of smoke, causing the alarm to fail.
Do not install this product near strong light sources, such as fluorescent lamps. Due to
electrical characteristics, strong light can cause false alarm on smoke alarms.
Do not install this product near metal sources. Strong metals will absorb wireless signals,
causing wireless functions to fail.
Warning
WarningWarning
Warning Please do not stop the false alarm by powering off. The smoke alarm stops the
alarm after the smoke in the detection unit has dissipated. If you want to stop the alarm
immediately, you can speed up the scattering of smoke inside the detection unit, such as
blowing.
4.
4.4.
4. INSTALLATION GUIDE
INSTALLATION GUIDEINSTALLATION GUIDE
INSTALLATION GUIDE
This product needs to be installed on the ceiling. You can refer to Chapters 3 of this article to
determine where to install the product. Please follow the steps below to install.
1. Draw a 15 cm line at the location you want to install.
2. Remove the back cover from the sensor.
3. Align the two elongated holes on the back cover with the previously drawn lines and mark the
two long holes on the line. .
4. Using a 5 mm drill bit, make two holes in the position where the long hole was previously
marked, then insert the two plastic expansion tubes into the hole, making sure that they are
completely immersed. Please be careful not to let the dust generated by the punch enter the
smoke sensor when punching.
5. Align the long hole on the back cover with the expansion tube and then screw the screw into the
expansion tube from under the back cover.
6. Install the battery into the smoke sensor. For details, please refer to the “Start up” section.
7. Fasten the smoke sensor to the back cover.
8. Press the test button on the alarm. If you hear the sound, it means the smoke sensor has
started working.

TECHNICAL DATA
TECHNICAL DATATECHNICAL DATA
TECHNICAL DATA
WIRELESS SMOKE
DETECTOR CM90
ARTRA Fire Protection, email
ARTRA Fire Protection, email ARTRA Fire Protection, email
ARTRA Fire Protection, email info@artra.co.id
[email protected], support technis
, support technis , support technis
, support technis http //www.artra.co.id/
http //www.artra.co.id/http //www.artra.co.id/
http //www.artra.co.id/
AR/DS/Doc-2010009 4 | P a g e
5.
5.5.
5. START
STARTSTART
START
“
“ “
“ This product requires
This product requires This product requires
This product requires 9 volt
9 volt9 volt
9 volt
battery, the smoke sensor will directly enter the self
battery, the smoke sensor will directly enter the selfbattery, the smoke sensor will directly enter the self
battery, the smoke sensor will directly enter the self-
--
-test and
test and test and
test and
login platf
login platflogin platf
login platform or other working conditions “
orm or other working conditions “orm or other working conditions “
orm or other working conditions “
Warning
Warning Warning
Warning Do not expose this product to high heat. In a high heat environment, the battery may
explode, leak, expand and other dangerous accidents.
The correct way to install the battery
1. Open the back cover of the product and you will see the battery compartment clearly.
2. The battery should be correctly aligned with the positive and negative terminals of the
battery compartment for installation.
3. After the battery is installed, try shaking the smoke alarm to ensure that the battery does
not come loose.
Note
1. When the smoke sensor is energized, the red light pole on the surface will light up for 0.5
seconds at the moment of power-on, and the buzzer will beep once. Then the battery is
connected correctly.
2. Press the button (the side with the word "TEST" in the figure), and the buzzer remit three
times of “di di di”. This feature is to indicate that the smoke alarm is currently working.
6.
6.6.
6. OPERATION PROCEDU
OPERATION PROCEDUOPERATION PROCEDU
OPERATION PROCEDURE
RERE
RE
Working status
Working statusWorking status
Working status
When you s
When you sWhen you s
When you saw
awaw
aw
Description
DescriptionDescription
Description
Smoke alarm
normal
In the App
“untriggered” Can see in the App
Battery weak
In the App
“sufficient” Can see in the App

TECHNICAL DATA
TECHNICAL DATATECHNICAL DATA
TECHNICAL DATA
WIRELESS SMOKE
DETECTOR CM90
ARTRA Fire Protection, email
ARTRA Fire Protection, email ARTRA Fire Protection, email
ARTRA Fire Protection, email info@artra.co.id
[email protected], support technis
, support technis , support technis
, support technis http //www.artra.co.id/
http //www.artra.co.id/http //www.artra.co.id/
http //www.artra.co.id/
AR/DS/Doc-2010009 5 | P a g e
7. DETECTION & ALARM RESET
DETECTION & ALARM RESETDETECTION & ALARM RESET
DETECTION & ALARM RESET
Press the button (the side with the word "TEST" in the figure), and the buzzer "di di di" is
called three times. This feature indicates that the current smoke sensor is working and
working properly. It is recommended to perform a button test once a month to ensure that
the smoke alarm is in operation.
Press the button (the side with the word “REST” in the figure). When the smoke alarm
sounds an alarm, this function can stop the current smoke alarm and return to normal
operation. After confirming that the alarm is a false alarm, press this button as soon as
possible to cancel the alarm.
Warning
Warning Warning
Warning Do not place this product in flame to test the alarm function of this product. This
is not only dangerous, but it is also very likely to damage the product. The only safe and
correct way to test is to use the test button for the alarm function test.
8.
8.8.
8. REPLACE THE BATTERY
REPLACE THE BATTERYREPLACE THE BATTERY
REPLACE THE BATTERY
When you hear a short beep every 60 seconds, this means your smoke sensor is already in
low battery. The low battery status will alert before the battery is completely drained, until
the battery is exhausted. This means you need to replace the battery immediately.
The steps to replace the battery are as follows
1. Remove the smoke sensor directly.
2. Remove the battery from the inside of the battery compartment.
3. Install a new battery, please refer to the “Start up” section for battery installation.
4. After the battery is installed, push the smoke alarm up to the back cover and press
the button test. If an alarm sound is heard, the smoke alarm has started working.
5. Install the battery to pay attention to the battery, positive and negative. Do not
reverse.
9.
9.9.
9. ALARM REST
ALARM RESTALARM REST
ALARM RESTR
RR
RICTIONS
ICTIONSICTIONS
ICTIONS
This product can only detect smoke particles and temperature. Other gas such as
carbon monoxide, natural gas, and liquefied gas cannot be detected.
This product is battery powered and the battery type is 9V battery. Using other
types of battery power may cause damage to the device.
Table of contents
Popular Smoke Alarm manuals by other brands

ABB
ABB FC650 Series Technical data

Abus
Abus RWM250 user manual

aguilera electronica
aguilera electronica AE002/OP Technical manual

Wheelock
Wheelock NS4-24MCW installation instructions

Edwards Signaling
Edwards Signaling 517TCSB Series installation instructions

Great Outdoors
Great Outdoors 2505G Assembly and owner's manual