ASCOM TACTICAL OPENACCESS NODE R - DATASHEET 1 User manual

PRODUCT SHEET
Product: Tactical openAccess Node R
Platform: Ascom openAccess®
Segement : Defense
Division: Security Communication
ASCOM TACTICAL openACCESS NODE R
MOBILE VOICE AND DATA SWITCH FOR
RADIO INTEGRATION
Ascom openAccess Nodes are integrated
voice and data switches that provide the
essential foundation for today’s mission critical
communications infrastructures. They are used
by national and international military forces,
peace keeping troops and crisis management
teams.
Ascom openAccess Nodes’ connectivity and
operational features provide secure and
scaleable functionality for voice, data and
imagery applications demanded in the combat
arena and homeland security relations.
Built on proven hardware and software
technology, Ascom compact network nodes are
compliant with global industry and governmen-
tal standards for vehicle and military grade
electronics.
In alignment with NATO TACOMS Post 2000 architecture, Ascom
Tactical openAccess Node R serves the role as voice and data radio access
point in mobile area sub-systems. Over legacy radio networks, it provides
interoperable communication access between field devices and separated
ad-hoc mobile headquarters. In mission critical operations this vital com-
munication link assures information flow at all levels from command head-
quarters to the troops.
Even with bandwidth limitations and restricted channel availability,
Ascom Tactical openAccess Node R truly extends the range of the core IP
network. It links into virtual LANs using tactical radio channels; but is also
equipped with multiple interfaces that allow LOS (Line-of-sight), meshed
WLAN and universal Ethernet connections. This capability allows fixed line
communication equipment and field radio devices to exchange information
that contribute to situational awareness and operational effectiveness.
Ascom Tactical openAccess Node R is highly reliable and adaptable to
a wide variety of extreme ad-hoc deployments. The watertight ultra rugged
enclosure is hermetically sealed to withstand severe humidity and dust
exposure as well as extreme temperatures. Its form-factor is optimally de-
signed for space/weight-constrained military vehicles and ground mobile
deployments. It is corrosion resistant; shock/vibration protected and can
be easily mounted in existing PR4G amplifier racks.

PRODUCT SHEET: TACTICAL OPENACCESS NODE R
Networking
Network topology Support for meshed network topologies.
Topology changes Dynamic routing adaptation in response to network
topology changes.
Routing Supports both unicast as well as multicast routing.
Routing path selection Best path selection across different network domains
(i.e. tactical radio network, LAN, military backbone).
Data Features
IP IPv4
DNS Built-in Domain Name Server for IP-address-to-name
and name-to-IP-address translation.
DHCP Built-in Dynamic Host Configuration Protocol server for
IP address assignment.
Radio Features
Tactical radio network
topology
Optimised network topology management for tactical
radio networks. No limitation on the type of radio
network topology.
Radio Connection 4x VHF / HF tactical radio (e.g. PR4G transparent data
interface and remote control interface supported)
ARQ Per-link ARQ across radio networks
Management Features
Management Remote configuration and monitoring based on SNMP
and Network Management Application (NMA).
Configuration storage
Storage of multiple configuration profiles. Configura-
tion changes are possible without reset or reboot.
Configurations can be backed up locally or remotely.
Update management Supports remote software updates.
Environmental Conditions
Temperature
Operation: -20..+55°C, MIL-STD-810F, 502.4, procedure
II, MIL-STD-810F, 501.4, procedure II
Storage: -30..+60°C, MIL-STD-810F, 502.4, procedure I,
MIL-STD-810F, 501.4, procedure I
Cooling
Cooling possible without external air exchange
If required, an internal fan activates the airflow and
optimises the cooling.
Humidity MIL-STD-810F, 507.3, proc. I, cycle 3 (95%RH) with
closed connector shields.
Waterproof MIL-STD-810F, 506.3, proc. II (dripping-water) with
closed connector shields.
Vibrations
MIL-STD-810F, method 514.4-4 AIII modified (depend-
ing on axis: 1…6.5g RMS, random on random 5 - 500Hz,
8Min/phase, total 40Min/axis, mounted in swing
frame)
Shock MIL-STD-810F, method 516.5, procedure I, 30g 11 ms
sawtooth, mounted in swing frame
EMC
Emissions
MIL-STD-461E (CE102, 10kHz – 10MHz, figure CE102-1
on 24 VDC; RE102, 10 kHz – 1GHz, figure RE102-4 /
army)
Immunity
MIL-STD-461E (CS114: figure CS114-1 on all cables,
10kHz-1MHz curve #3, 1MHz-30MHz curve #4, 30MHz-
200MHz curve #4; RS103: 30MHz – 1GHz 20V/m,
30MHz–18GHz 50 V/m).
ESD air discharge with 8kV, contact discharge with 4kV
according to IEC 61000-4-2.
Burst 1 kV according to IEC 61000-4-4 coupling gripper
on the cable.Burst 1 kV according to IEC 61000-4-4
direct coupling on 24V line.
Surge on 24VDC: according to EN 61000-6-2 (Immunity,
Industry, Table 3 dc power port); line-to-earth +/- 0.5kV
1.2 / 50 us (8/20), 12 Ohm; line-to-line: +/- 0.5kV 1.2 /
50 us (8/20), 2 Ohm.
Mechanical
Size (LxHxD)/mm 279x105x215 (without connectors)
Weight 6kg
Connectors Circular interface and power supply plugs, mounted on
front side
Power
Input voltage 24VDC (18-33VDC)
Power consumption 20W nominal, 30W maximal
Power autonomy An internal lithium-polymer storage battery 24V /
1.5Ah provides power for 5 minutes.
Available Interfaces
Remote relay Relay I/O control over IP
Serial lines 6 x asynchronous port 16C550 compatible
4 x synchronous port
Switched Ethernet 2 x 10Base-T / 100Base-TX
Service interface 1xUSB 2.0, 1xRS-232
User Interfaces
Display 2-digit process display
Status PC (HD and LAN activity)
Operational displays radio control, supply power, fans, temperature, storage
battery
Switches / keys On/Off Reset Test
Technical Specification

PRODUCT SHEET: TACTICAL OPENACCESS NODE R
Base Board
CPU Low Power Pentium-M 738, 1.4 GHz, 2MB L2 cache,
64bit data bus
Chip set Intel 855GME
Front side bus 400MHz
BIOS 1MB Flash EEPROM
RAM 1 GByte
Persistent storage 4 GByte DOM (Disk on module)
Internal fans 1x, monitored, temperature controlled
Internal Expansion Units
Slot type PC/104-Plus
Number of slots 2 (1 free, with 22 pin MIL connector equipped)
4xSynch PC104 4xsynchronous ports per unit for up to 4 radios
Maintenance
Maintenance interval 4 years (change of lithium storage battery)
Technical Specification

PRODUCT SHEET: TACTICAL OPENACCESS NODE R
Although the information in this publication is represented in good faith and believed to be correct, Ascom makes no representations or warranties
as to the completeness or accuracy of the information. In no event will be Ascom responsible for damages of any nature whatsover resulting from the
use of or reliance upon the information contained in this document. Such information is subject to change without notice. Ascom gives no warranty
and makes no representation that any of its products contained in this document are designed for any particular use or purpose. The graphics and
contents of this document are the copyrighted work of Ascom and contain proprietary trademarks and tradenames of Ascom.
Ascom (Switzerland) Ltd. Ascom (Finland) Oy Ascom Poland SP. z.o.o. Ascom (CZ) s.r.o.
Belpstrasse 37 Pakkalankuja 6 Ul. Farbiarska 71a Zemské právo 1199/5
CH-3000 Bern 14 FI-01510 Vantaa PL-02-862 Warsaw CZ-10200 Praha 10
T+ 41 31 999 13 65 T + 358 9 825 901 T +48 22 544 22 00 T + 420 267 219 512
F + 41 31 999 16 82 F + 358 9 825 902 79 F + 48 22 544 22 05 F + 420 267 219 511
www.ascom.com/defense www.ascom.fi www.ascom.com.pl www.ascom.cz
01.2010 © Ascom (Switzerland ) Ltd.
This manual suits for next models
1
Other ASCOM Switch manuals
Popular Switch manuals by other brands

Linkskey
Linkskey LDV-DM02ESK Quick installation guide

HeroSpeed
HeroSpeed RT2418 Series quick start guide

ATEN
ATEN Master View CS-9134 user manual

Generac Power Systems
Generac Power Systems GTS "W" owner's manual

Lucent Technologies
Lucent Technologies LambdaUnite installation guide

RFL Electronics
RFL Electronics RFL 9660 instruction manual