Copyright © 2003, 2018, 2019, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Corbin Russwin, Inc.
225 Episcopal Road
Berlin, CT 06037 USA
Phone: 800-543-3658
Fax: 800-447-6714
www.corbinrusswin.com
FM219 07/19
1 Cylinder Collar Chart
Cylinder Length Collar
1-1/8" (29mm) 270F15
1-1/4" (32mm) 654F07
1-1/2" (38mm) 654F08
2 Double Cylinder Trim Housing Installation (supplied with device)
Follow 955 Series trim installation instructions.
Substitute cylinder housing assembly with Double
Cylinder Trim Housing Assembly supplied with device.
(Figure 2) Continue with trim mounting instructions.
1. Follow ED5200(A) mounting instructions (supplied with
device). Once complete, continue with Double Cylinder
instructions below.
2. Pre-assemble cylinder through cylinder collar, active head
cover and cylinder housing as shown on the cover page.
Secure cylinder housing to cylinder with two (2)
10-24 x 3/4" cylinder screws. Keyway position should be vertical with
plug-in lower side of cylinder. (Figure 3)
3. Assemble active head cover to device by inserting cylinder tailpiece into lazy cam
slot of Double Cylinder Trim Housing Assembly. (Figure 2) Adjust tailpiece
length as needed to prevent interference with opposing trim cylinder. Install
and tighten two (2) 8-32 x 1/4" cover screws to active head cover.
4. Check for proper functional operation of trim and exit device.
Cylinder
Length
Figure1
Cam tip (this side)
Lazy Cam Slot
(2) Cylinder
Mounting Screws
Figure2
Figure3