Assa Abloy ARROW 5016NH User manual

For technical support contact 800.438.1951
80-9311-3008-021 05/19
Copyright © 2019, ASSA ABLOY Access and Egress Hardware Group, Inc.
All rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Hold Open Arm Models
5016NH
Non Handed Door Closer
Regular Arm
Top Jamb Mount
Parallel Arm
With or without D sufx (delayed action)
Ce produit peut vous exposer au plomb qui, dans l’état de la Californie,
est reconnu pour causer le cancer, des anomalies congénitales ou d’autres
problèmes de reproduction. Pour plus d’informations, visitez:
www.P65warnings.ca.gov.
This product can expose you to lead which is known to the state of
California to cause cancer and birth defects or other reproductive harm.
For more information go to www.P65warnings.ca.gov.
WARNING
Regular Arm Top Jamb Mount
*Included Components
Parallel Arm
Optional Plates
Right Hand Door - RH
Left Hand Reverse - LHR
Left Hand Door - LH
Right Hand Reverse - RHR
Right Hand Door - RH
Left Hand Reverse - LHR
Left Hand Door - LH
Right Hand Reverse - RHR
Tools Needed
TO DETERMINE
HAND OF
YOUR DOOR:
LEFT
HAND
DOOR
RIGHT
HAND
DOOR
Right Hand
Reverse
Left Hand
Reverse
To Determine Your Hand of Door: To Identify Your Model:
Right Hand Door - RH
Left Hand Reverse - LHR
Left Hand Door - LH
Right Hand Reverse - RHR
Optional Covers

2
80-9311-3008-021 05/19
For technical support contact 800.438.1951
Copyright © 2019, ASSA ABLOY Access and Egress Hardware Group, Inc.
All rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Use provided hex wrench to turn valves.
NEVER force valves out of closer. NEVER
completely close backcheck valve.
Door must be open to adjust spring
closing power. Refer to chart. Do not use
a power drill. Warranty will be void.
Before You Begin
• “D” sufx (Delayed Action) is an optional feature.
• For special applications, a separate door and frame
preparation template is packed with these instructions. Use
this instruction sheet for installation sequence and closer
adjustments only.
• Doors should be hung on ball bearing or anti-friction hinges.
Mounting Hardware Door or Frame Drill
Closer, H/O Shoe or Optional PA Bracket:
1/4-14 x 1-1/2 Oval Flat Head Mach. Screw Wood 3/16" (4.76mm)
Closer, H/O Shoe or Optional PA Bracket:
1/4-20 x 3/4 Oval Flat Head Mach. Screw Metal Drill #7 (.201 dia. or 5.10mm)
Tap 1/4-20
H/O Shoe to Optional PA Bracket:
1/4-20 x 1/2 Oval Flat Head Mach. Screw
Closer:
Sleeve Nut and Bolt (SNB)
(optional)
Hollow Metal 9/32" (7.00mm) thru
3/8" (9.50mm) door face opposite to closer
Aluminum or Wood 3/8" (9.50mm) thru
Closer:
Thru Bolt and Grommet Nut (TBGN)
(optional)
All
9/32" (7.00mm) thru
3/8" (9.50mm) dia. x 3/8" (9.500mm) deep,
door face opposite to closer
• A separate door stop is recommended.
• Always consult door/frame manufacturer for fastener compatibility.
• Door and frame must be properly reinforced.
• Adjust closing time speed between 3 and 7 seconds from 90° to 0°.
Greater closing times may be required for elderly or handicapped.
• These door closers should NOT be installed on exposed side
(weather side) of exterior doors.
• Dimensions are given in inches (millimeters).
ATTENTION:
An incorrectly installed or improperly adjusted door closer can
cause property damage or personal injury. These installation
instructions should be followed to avoid the possibility of
misapplication or misadjustment.
Closer Adjustments
Do not over tighten
cover screws.
Cover
Latch
Backcheck
Sweep
Regular Arm Top Jamb Mount Parallel Arm
Optional
Delayed Action
5016NH Installation Instructions

3
80-9311-3008-021 05/19
For technical support contact 800.438.1951
Copyright © 2019, ASSA ABLOY Access and Egress Hardware Group, Inc.
All rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
1. Prepare door and frame.
2. Mount closer to door. 3a. Remove dial from
Hold Open arm.
4. Connect arms, preload spring
and tighten set screw.
3b. Install separate arms.
5016NH Regular Arm Installation (Right Hand Shown)
Opening
To 100°
101° to 130°
131° to *180°
7-1/2
(191)
6
(152)
4-1/2
(114)
Dimension "A"
Door/Wall/Hardware/Jamb
*conditions permitting
5-1/2
(140)
1-3/4
(44)
1-1/4
(33)
3/4
(19)
1-5/8
(41)
A
12
(304.8)
You’ve installed the 5016NH Hold Open Closer - Regular Arm.
🛑
Go to page 2 for closer adjustments and decorative cover installation.
Dial DOWN
Left and Right Hand
RH and LH:
Position at at S
1st
2nd 3rd
1st
3rd 2nd
Rotate elbow until
Hold Open arm is
perpendicular to frame.
Rotating arm
preloads closer
spring power.
RH:
Clockwise
to tighten.
LH: Counter
clockwise to
tighten.
1st
3rd
2nd
5. Set Hold Open. Keep door open in position
until dial screw secures dial.

4
80-9311-3008-021 05/19
For technical support contact 800.438.1951
Copyright © 2019, ASSA ABLOY Access and Egress Hardware Group, Inc.
All rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
5016NH Top Jamb Mount Installation (Right Hand Shown)
1. Prepare door and frame.
2. Mount closer to frame.
Door/Wall/Hardware/Jamb
*
conditions permitting
Opening
To 100°
101° to 130°
131° to *180°
7-1/2
(191)
6
(152)
4-1/2
(114)
Dimension "A"
A longer connecting
rod is required
for reveals greater
than 3" (76)
Reveal
3a. Remove dial from
Hold Open arm.
3b. Install separate arms.
12
(304.8) 3/4
(19)
1/2
(13)
5-1/2
(140)
1-7/8
(48)
1-3/4
(44)
C
L
A
Top of
Frame
You’ve now installed the 5016NH Hold Open Closer - Top Jamb Mount.
🛑
Go to page 2 for closer adjustments and decorative cover installation.
Dial DOWN
Left and Right
Hand
RH and LH:
Position at at S
5. Set Hold Open.
1st
2nd
3rd
Rotate elbow until
Hold Open arm is
perpendicular to frame.
Rotating arm
preloads closer
spring power.
Keep door open in position
until dial screw secures dial.
3rd
1st
3rd
1st
2nd
RH:
Clockwise
to tighten.
LH: Counter
clockwise to
tighten.
2nd
4. Connect arms, preload spring
and tighten set screw.

5
80-9311-3008-021 05/19
For technical support contact 800.438.1951
Copyright © 2019, ASSA ABLOY Access and Egress Hardware Group, Inc.
All rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
5016NH Parallel Arm Installation (Right Hand Shown)
1. Prepare door and frame.
2. Close latch and sweep
valves.
4. Install soft plate and mount closer.
5. Install Hold Open arm to plate. 6. Place main arm on closer spindle and rotate.
R
o
t
a
t
e
Dial DOWN
Left and Right Hand
3. Remove dial from
Hold Open arm.
IMPORTANT
Door/Wall/Hardware/Jamb
*conditions permitting
Door
Opening
To 120°
121° to 180°
*
A
9-1/2
(241)
7
(178)
B
3-3/4
(95)
1-1/4
(32)
C
L
2-3/4
(70)
A
3/8
(10)
1/2
(13)
7/16
(11)
2
(50)
3-5/8
(92)
3/4
(19)
B
Top of
Door
Frame
12
(304.8)

Arrow Lock is a business associated with ASSA ABLOY Access and Egress Hardware Group, Inc., an ASSA ABLOY Group
company. Copyright © 2019, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in
whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited. 80-9311-3008-021 05/19
ARROW USA
3625 Alleghany Dr.
Salem, VA 24153
Phone: (800) 839-3157
Fax (800) 421-6615
arrowlock.com
ASSA ABLOY is the global
leader in door opening solutions,
dedicated to satisfying
end-user needs for security,
safety and convenience
7. Remove arm and attach as shown. 8. Open latch and sweep valves.
9. Connect arms, preload spring and
tighten set screw.
10. Set Hold Open.
Do not completely
open valves. Valves
will leak.
Arm under tension.
Keep ngers away
from moving parts.
1-1/2
(38)
1st
2nd
3rd
5th
4th
By hand,
position arm
elbow to be
1-1/2" from
door face.
You’ve now installed the 5016NH Hold Open Closer - Parallel Arm.
🛑
Go to page 2 for closer adjustments and decorative cover installation.
Rotating arm
preloads closer
spring power.
Keep door open in position
until dial screw secures dial.
1st
3rd
3rd
2nd
RH:
Clockwise
to tighten.
LH: Counter
clockwise to
tighten.
2nd
1st
1st
2nd
RH: Position at at R
LH: Position at at L
5016NH Parallel Arm Installation (Right Hand Shown) continued
Table of contents
Other Assa Abloy Intercom System manuals