ASTi SYNAPSE Voisus User manual

ASTi SYNAPSE
Voisus Server
Manual
Document: DOC-01-SYN4-VS-1
Advanced Simulation Technology inc. 500A Huntmar Park Drive, Herndon, Virginia, 20170 USA
Revision F1 (May, 2012)


Product Name: ASTi Synapse Voisus Server
Description: Network Voice Communications System
Part Number:
SYN-VS-
Number of Radios
ASTi Synapse Voisus Server Manual
© Copyright ASTi 2010-12.
Restricted Rights: Use, duplication, or disclosure by the Government is subject to restrictions as set forth in sub-
paragraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013.
This material may be reproduced by or for the U.S. Government pursuant to the copyright license under the
clause at DFARS 252.227-7013 (1994).
ASTi
500-A Huntmar Park Drive
Herndon, VA 20170


i
Table of Contents
1.0. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1. Overview ................................................................................................................................. 1
Figure 1: Synapse Application Example .................................................................................... 2
2.0. GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1. System Hardware ................................................................................................................... 4
2.2. USB Adapters and Headsets .................................................................................................5
2.3. System Hardware Installation ............................................................................................... 7
Figure 2: Common Network Configuration ................................................................................. 7
Figure 3: Separate Network Configuration ................................................................................. 9
Figure 4: Network Ports ........................................................................................................... 11
Figure 5: ACE-RIU Front Panel ............................................................................................... 12
Figure 6: ACE-RIU Rear Panel ................................................................................................ 12
3.0. SYSTEM SETUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.1. ACE Studio Setup ................................................................................................................. 13
3.2. Telestra Setup ....................................................................................................................... 15
3.3. ACE-RIU Setup ..................................................................................................................... 19
4.0. SYSTEM SOFTWARE CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.1. Creating a Layout in ACE Studio ........................................................................................ 22
5.0. VOISUS CLIENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
5.1. Client System Requirements ............................................................................................... 34
5.2. Choosing an Audio Device on the Client ........................................................................... 35
6.0. CLIENT SOFTWARE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 7: RMS Voisus Downloads ........................................................................................... 37
6.1. Linux Installation .................................................................................................................. 38
6.2. Windows Installation ............................................................................................................ 40
7.0. STANDARD CLIENT GUI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
7.1. Operator Settings ................................................................................................................. 46
7.2. Headset Settings .................................................................................................................. 47
Figure 8: Headset Settings ...................................................................................................... 47
Figure 9: Headset Tests ........................................................................................................... 48
8.0. TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
8.1. Voisus Networking Error Messages ................................................................................... 53
9.0. FAQs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

ii
10.0. CLIENT SECURITY FIREWALL CONFIGURATION . . . . . . . . . . . . . . . . . . . . 55
10.1. RedHat Enterprise Linux ................................................................................................... 55
10.2. Microsoft Windows ............................................................................................................ 57
APPENDIX A: COLD START . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
APPENDIX B: SAFETY and HANDLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
APPENDIX C: WARRANTY AND CUSTOMER SUPPORT . . . . . . . . . . . . . . . . . . . 60
Warranty ....................................................................................................................................... 60
Repairs and Returns ................................................................................................................... 60
APPENDIX D: VOISUS-VBS2 PLUGIN INSTALLATION . . . . . . . . . . . . . . . . . . . . . 61
ASTi Keybinding Map ................................................................................................................. 74
VBS2 Client Radio Key ............................................................................................................... 74
Nets ............................................................................................................................................... 75
Voisus-VBS2 Plugin Troubleshooting Procedures .................................................................. 76

ASTi Synapse Voisus Server Manual (Ver. 1, Rev. F1)
Copyright © 2012 Advanced Simulation Technology inc. 1
1.0. INTRODUCTION
1.1. Overview
Synapse Voisus Server is an affordable, client-server based simulated radio and intercom commu-
nications solution. The server is dedicated to heavy simulation processes and extends the power-
ful ASTi Radio environment to Voisus thin clients running on customers’ PCs. Voisus clients
conserve CPU resources, maximize reliability and minimize maintenance (server-centralized soft-
ware updates). The Synapse Voisus Server has elegant administration, simply download the client
application from the server, remotely configure, and operate.
The server is a Telestra with the full-fidelity ASTi Radio environment. Server also features a DIS
Interface (HLA optional) and a network link to Voisus clients. Voisus Server is configured using
Studio.
The Voisus client is a communication operator GUI panel with remote IP audio. The client appli-
cation is downloadable using the Remote Management System web interface.
Configuration and operation is easy with three simple steps:
1. Point your web browser at the Telestra to access the Remote Management System and
download the client.
2. Use Studio to remotely configure the network and clients’ access to ASTi radios.
3. Communicate using the client GUI.
Synapse Voisus Server features:
• Voisus Client supports single-user ASTi operator
• Remote configuration using Studio
• Variety of client GUIs available: Voisus standard, SINCGARS and other MIL radios, and
VBS2 overlay, Custom GUIs available, contact ASTi for details.
• Client includes a GUI comm panel providing access to multiple ASTi radios and intercoms
• Voisus Server is inter-operable with Synapse Workstation (integrating hardware-based oper-
ator stations) and Synapse Radio Bridge (integrating live radio traffic).

ASTi Synapse Voisus Server Manual (Ver. 1, Rev. F1)
2Copyright © 2012 Advanced Simulation Technology inc.
Here is a live-virtual-constructive (L-V-C) application example for an ASTi Synapse Voisus
Server integrated with a Synapse Workstation, Radio Bridge, Telestra-based flight simulator and
an ACE Studio master control station. Capabilities realized:
• Links geographically disperse facilities
• Provides interoperable voice comms by linking diverse environments (simulators, comput-
ers, live-field comms)
• Provides centralized exercise management
IP
Communication
Network
U.S. Navy, Analysis Cell
Joint Forces, Exercise Control
Studio
USAF, Special Ops Squadron
USMC, Live Fire Range
Live SINCGARS
Telestra 4 Integrated
with Flight Simulator
Synapse Voisus Server
Synapse Radio-IP Bridge
Synapse Workstation
Live RF Comms
IP Network Comms
Remote Monitor & Management
ACENet, Digital Audio &
Remote Radio Control
Features Voisus Clients, hosted on
customer-furnished Linux or Windows PC
IP
Network
US Army, Task Force HQ
Exercise Planner & Monitor
Remote Mgmt. System (RMS)
Simulated Radio App (optional)
Figure 1: Synapse Application Example

ASTi Synapse Voisus Server Manual (Ver. 1, Rev. F1)
Copyright © 2012 Advanced Simulation Technology inc. 3
Voisus Server’s network-centric architecture is highly scalable; simply connect more client posi-
tions to the IP network and centrally manage using the Voisus Server. Client-based operators can
be located wherever there is access to the network.
Voisus Server features:
•Flexible and Scalable Architecture: Configure server modules to meet custom require-
ments.
•Interoperable: Inter-operates with full fidelity radio simulations.
•Deployable out-of-the-box: Connect, configure, operate.
•DIS/ HLA Compliant: Synapse is inter-operable with a vast array of simulators, data anal-
ysis and data logging tools.
•Simple to Install: Modular/ click-together, all-Ethernet installation.
•Simple to Run: Even novice users can exploit the capabilities of ASTi’s powerful and intu-
itive ACE software.
•Robust and Reliable: Industrial hardware, Intel Quad Core CPU, Realtime LinuxTM OS.

ASTi Synapse Voisus Server Manual (Ver. 1, Rev. F1)
4Copyright © 2012 Advanced Simulation Technology inc.
2.0. GETTING STARTED
2.1. System Hardware
The standard Synapse Voisus Server includes the following components.
Description SYN-0S Standard Feature
Telestra 1 Yes
ACE-RIU 1Yes
Operator headsets, USB adapters and
PTT ancillaries
various Available Separately

ASTi Synapse Voisus Server Manual (Ver. 1, Rev. F1)
Copyright © 2012 Advanced Simulation Technology inc. 5
2.2. USB Adapters and Headsets
Voisus clients are compatible with the following USB adapters and headsets. All of the listed USB
adapters provide built-in sidetone. Sidetone is a critical feature that provides the client operator
with an audible indication that they are actively transmitting.
USB Adapters
ASTi Part Number Manufacturer Built-In PTT Compatible Headsets
USB-RADIUS-010 ASTi Yes Specific Telex (see list)
USB-P-DA40 Plantronics No All Plantronics H-Series
(see list*)
USB-P-SHS2355 Plantronics Yes All Plantronics H-Series
(see list*)
Headsets
Note: Some headsets require USB adapters.The logitech (HS-LG-G35) does not require an
adapter.
ASTi Part Number Manufacturer Stereo**
Mono Ear Cups
HS-TX-PH-44R5 Telex Stereo Dual, light weight
HS-TX-HR-2R5 Telex Stereo Dual, noise isolation,
medium weight
HS-P-H251 Plantronics Mono Single, light weight
HS-P-HW261N Plantronics Mono Dual, light weight
HS-P-SHR2083-01 Plantronics Mono Dual, noise isolation,
medium weight
HS-LG-G35 Logitech Stereo Dual, noise isolation,
heavy weight
** Stereo headsets are recommended for use with Voisus-VBS2 plugin.

ASTi Synapse Voisus Server Manual (Ver. 1, Rev. F1)
6Copyright © 2012 Advanced Simulation Technology inc.
Speakerphones
ASTi Part Number Manufacturer Features
USB-P-P420 Plantronics Mic mute and volume controls, active
echo cancellation, and auxiliary head-
phone jack
Note: Plantronics sales literature states that Plantronics USB adapters are compatible with all
Plantronics H-Series headsets. ASTi has tested and validated Voisus clients using the listed Plan-
tronics headsets.
Plantronics®is a registered trademark of Plantronics, Inc.
TelexTM is a trademark of Telex Communications, Inc.

ASTi Synapse Voisus Server Manual (Ver. 1, Rev. F1)
Copyright © 2012 Advanced Simulation Technology inc. 7
2.3. System Hardware Installation
2.3.1. Network Configurations
Voisus Server utilizes three application network traffic links:
• Studio: Central management station
• DIS*: Inter-Server (or inter-simulator) communications
• Voisus: Server-Client communications
*Distributed Interactive Simulation (DIS), IEEE-1278 standard
Figure 2 shows the most basic network configuration for the Voisus Server system. All three
application links share a common IP network. The benefit of this configuration is simplicity.
Telestra ACE Studio
(See Note)
DIS
Analog Voice
Operator 1 & 2 Operator 3 & 4 Operator 5 & 6 Operator 7 & 8
DIS and
Voisus
IP Network Comms
RIU1
Eth1
Advanced Simulation Technology,Inc.
CHAN A CHAN B CHAN C CHAN D
USB Voice & PTT
Headset
USB Adapter
(PTT Optional)
To Other ASTi
Communications Systems
Eth0
Figure 2: Common Network Configuration
See note on following page.

ASTi Synapse Voisus Server Manual (Ver. 1, Rev. F1)
8Copyright © 2012 Advanced Simulation Technology inc.
Note: ACE Studio provides centralized, network-based tools that are used to configure and man-
age Synapse systems. There are two Studio packages available:
• Studio VM (virtual machine) is provided with every Synapse system. Studio VM is a soft-
ware-only product that installs on customer-furnished Windows®or LinuxTM computers.
• Studio integrated on a Telestra platform. This preconfigured system is available separately.
One ACE-RIU is required for each Synapse Voisus Server to provide system synchronization.

ASTi Synapse Voisus Server Manual (Ver. 1, Rev. F1)
Copyright © 2012 Advanced Simulation Technology inc. 9
Figure 3 shows a separate network configuration, with Studio and DIS application traffic on one
IP network (DIS) and Voisus application traffic on another network (Voisus). The benefit of this
configuration is network traffic management. Using this configuration, traffic segregation eases
congestion on each network. Also, computers on each network are isolated from superfluous traf-
fic (for example, Voisus client computers are not subjected to DIS traffic), which conserves pro-
cessing resources.
Telestra ACE Studio
(See Note)
DIS
Analog Voice
Operator 1 & 2 Operator 3 & 4 Operator 5 & 6 Operator 7 & 8
DIS
Network
Eth0
To Other ASTi
Communications Systems
Voisus
IP Network Comms
RIU1
Eth1
Advanced Simulation Technology,Inc.
CHAN A CHAN B CHAN C CHAN D
USB Voice & PTT
Headset
USB Adapter
(PTT Optional)
Eth2
Figure 3: Separate Network Configuration

ASTi Synapse Voisus Server Manual (Ver. 1, Rev. F1)
10 Copyright © 2012 Advanced Simulation Technology inc.
2.2.2. ACE Studio Installation
There are two Studio packages available:
• Studio VM (virtual machine) is provided with every Synapse system. Studio VM is a soft-
ware-only product that installs on customer-furnished Windows®or LinuxTM computers.
• Studio integrated on a Telestra platform. This preconfigured system is available separately.
In addition to the ACE Studio platform, you will need the following items:
• Monitor
• Keyboard
• Mouse
• Power Supply
• CAT5 or CAT6 cable
• Network connection
Follow these steps to install the ACE Studio platform:
1. Connect to a monitor, keyboard and mouse.
2. Connect ethernet port to an IP network (common with all of the Synapse systems that will
be remotely managed by the ACE Studio). See section 2.2.1. for network configuration
guidance.
3. Connect to power.

ASTi Synapse Voisus Server Manual (Ver. 1, Rev. F1)
Copyright © 2012 Advanced Simulation Technology inc. 11
2.2.3. Telestra Installation
The Synapse Voisus Server is hosted on the Telestra platform. In addition to the Telestra chassis,
you will need the following items:
• Monitor
• Keyboard
• Power cord
• CAT5 or CAT6 cable
• Network connection
Ethernet Port Connections
Port Connection
Eth0 DIS (Inter-Telestra Comms)
Voisus (Telestra - Client Computer Comms)
Eth1 ACENet (ACE-RIU)
Eth2 Voisus (Telestra - Client Computer Comms, Alter-
nate Configuration)
PROPERTY OF
ASTI
0000
Network Ports
See chassis labels for ethernet assignment
Ethernet labels will be Eth0, Eth1, and Eth2
Figure 4: Network Ports
Please read the Eth0, Eth1, and Eth2 labels on your system to verify the Ethernet locations.
Follow these steps to install the Telestra platform:
1. Connect Telestra platform to a monitor and keyboard. Note that a monitor and keyboard
are only necessary for initial software configuration.
2. Connect the Telestra’s Ethernet interface(s) to the Studio management system, the Voisus
client computers and the DIS network (linking to other Telestras). See section 2.2.1. for
network configuration guidance.
3. Connect to power.

ASTi Synapse Voisus Server Manual (Ver. 1, Rev. F1)
12 Copyright © 2012 Advanced Simulation Technology inc.
2.2.4. ACE-RIU Installation
One ACE-RIU is required for each Synapse Voisus Server to provide system synchronization.
Important: The ACE-RIU in the Voisus Server configuration is not used to produce audio. Do not
connect headsets to the device.
Refer to Figure 2 for top level system installation guidance.
Advanced Simulation Technology, Inc.
CHAN A CHAN B CHAN C CHAN D
Figure 5: ACE-RIU Front Panel
Serial Ports
AB
Status
Power
+15VDC
1 2 3 4
ACENet
Figure 6: ACE-RIU Rear Panel
In addition to the ACE-RIU, you will need the following items:
• ACE-RIU Power Supply
• CAT5 or CAT6 cable
Follow these steps to install the ACE-RIUs:
1. Connect the ACE-RIU Ethernet port (ACENet) to Eth1 on the Telestra, using a CAT5
cross-over cable or a switch and CAT5 patch cable.
2. Connect to a furnished 15 volt power supply. IMPORTANT: Use only the ASTi furnished
power supplies for this purpose. Use of other power supplies may result in equipment
damage not covered by the product warranty or degraded product performance.

ASTi Synapse Voisus Server Manual (Ver. 1, Rev. F1)
Copyright © 2012 Advanced Simulation Technology inc. 13
3.0. SYSTEM SETUP
3.1. ACE Studio Setup
ACE Studio provides centralized, network-based tools that are used to configure and manage
Synapse systems. There are two Studio packages available:
• Studio VM (virtual machine) is provided with every Synapse system. Studio VM is a soft-
ware-only product that installs on customer-furnished Windows®or LinuxTM computers.
• Studio integrated on a Telestra platform. This preconfigured, ready-to-use system is avail-
able separately.
The following instructions apply to both Studio VM and integrated Studio products.
1. Power on the ACE Studio and allow it to boot.
2. Log into the ACE Studio:
Username: aceuser Password: aceuser
3. In the top left corner select System > Administration > Networks.

ASTi Synapse Voisus Server Manual (Ver. 1, Rev. F1)
14 Copyright © 2012 Advanced Simulation Technology inc.
4. Check the ‘Profile’ box and then select ‘Edit.’
5. Select the ‘Statically set IP addresses’ fill button.
6. Enter the IP address and Subnet mask.
Contact your network administrator for valid IP addresses and subnet masks for the net-
work(s) where the Telestra platform and ACE Studio will be integrated.
Table of contents
Other ASTi Server manuals
Popular Server manuals by other brands

Lenovo
Lenovo ThinkSERVER TS130 warranty and support information

Toshiba
Toshiba SD-H400 - Combination Progressive-Scan DVD... Specifications

Vxl
Vxl Itona TC73yy Hardware user's guide

Lenovo
Lenovo ThinkServer RD230 manual

Panasonic
Panasonic AJ-HDR150P operating instructions

Lanner
Lanner FW-7581 user manual