13
CAUSE CORRECTIVE ACTION
_________________________________________________________________________________________________________________________________
I. ELECTRICAL
_________________________________________________________________________________________________________________________________
A. NO VOLTAGE IN POWER SYSTEM Check phase-to-phase on line side of starter contactor.
Check circuit breaker or fuses.
_________________________________________________________________________________________________________________________________
B. NO VOLTAGE ON ONE PHASE Check phase voltage on line side of starter contactor. Isolate open
(THREE PHASE UNITS) circuit (circuit breaker, fuse, broken connections, etc.)
_________________________________________________________________________________________________________________________________
C. LOW VOLTAGE AT MOTOR Running voltage across each leg of motor must be ±10% of nominal
voltage shown on nameplate.
_________________________________________________________________________________________________________________________________
D. MOTOR LEADS IMPROPERLY GROUPED Refer to lead grouping diagram on motor nameplate.
FOR VOLTAGE
_________________________________________________________________________________________________________________________________
E. CONTROL FAILURE Check control device, starter contactor, H-O-A selector switch, etc.,
for malfunction.
_________________________________________________________________________________________________________________________________
F. THERMAL OVERLOAD SWITCH OPEN Check for drag or other overload.
_________________________________________________________________________________________________________________________________
G. INSULATION FAILURE Check motor or windings to ground with megohmmeter.
_________________________________________________________________________________________________________________________________
H. OPEN WINDINGS Check leg-to-leg with ohmmeter.
_________________________________________________________________________________________________________________________________
I. FREQUENCY VARIATION Check frequency of power system. Must be less than 5% variation from
motor nameplate rating.
_________________________________________________________________________________________________________________________________
J. WRONG DIRECTION OF ROTATION Reverse rotation of three phase motor by interchanging any two leads.
See Manufacturer's Instructions for reversing single phase motor.
_________________________________________________________________________________________________________________________________
2. MECHANICAL
_________________________________________________________________________________________________________________________________
A. FLOW THROUGH PUMP COMPLETELY OR Locate and remove obstruction. Refer to Repair Instructions
PARTIALLY OBSTRUCTED for disassembly.
_________________________________________________________________________________________________________________________________
B. PUMP NOT PRIMED Reprime. Inspect suction system for air leaks.
_________________________________________________________________________________________________________________________________
C. INTERNAL LEAKAGE Check impeller for wear of controlled clearances. (See Repair Instructions.)
_________________________________________________________________________________________________________________________________
D. LOOSE PARTS Inspect, repair.
_________________________________________________________________________________________________________________________________
3. SYSTEM
_________________________________________________________________________________________________________________________________
A. PRESSURE REQUIRED BY SYSTEM AT DESIGN Compare pump pressure and flow rate against pump characteristic curve.
FLOW RATE EXCEEDS PRESSURE RATING OF Check for closed or partially closed valve in discharge piping system.
PUMP Reduce system pressure requirement. Increase pressure capability of pump.
_________________________________________________________________________________________________________________________________
B. OBSTRUCTION IN SUCTION PIPING Locate and remove obstruction.
_________________________________________________________________________________________________________________________________
C. PRESSURE RATING OF PUMP EXCEEDS Compare pump pressure and flow rate against pump characteristic curve.
PRESSURE REQUIREMENT OF SYSTEM AT Inspect discharge piping system for breaks, leaks, open by-pass valves, etc.
DESIGN FLOW RATE If necessary, reduce flow rate by partially closing discharge valve.
_________________________________________________________________________________________________________________________________
D. SUCTION LIFT EXCEEDS 10' DESIGN Locate pump closer (vertically) to water source.
MAXIMUM.
PROBABLE CAUSE
GROUP 1 GROUP 2 GROUP 3
SYMPTOM ELECTRICAL MECHANICAL SYSTEM
ABCDE FGH I J ABCDABCD
PUMP RUNS, BUT NO
WATER DELIVERED •• •• •
NOT ENOUGH WATER DELIVERED •• ••••••
NOT ENOUGH PRESSURE •• ••••••
EXCESSIVE VIBRATION •• • • • •
ABNORMAL NOISE ••• • ••
PUMP STOPS ••••••••
OVERHEATING ••• •• •• •
TROUBLE SHOOTING