manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ATAGO
  6. •
  7. Measuring Instrument
  8. •
  9. ATAGO PAL- HIKARi 12 User manual

ATAGO PAL- HIKARi 12 User manual

Introduction
Measurement tips and precautions
Replacing the Batteries
Error Meassages
Thank you for purchasing the instrument.
Read and follow all safety instructions
before operating the instrument.
Fairure to comply with the following instruc-
tions may result in personal injury or property
damages.
The instrument reads Brix (sugar level) by
sending infrared light into the fruit and then
measuring its light absorption.
Brix (sugar level) can be measured without the
need to cut open or squeeze the fruit.
You will also be alerted if there is a watercore
present.
Measurment variance may be seen depending
on the variety and harvest timing. This instru-
ment is equipped with offset function to match
the value in such cases.
5462-E11
QR code
The warranty period extension method 1 year  2 years
The warranty period will be extended from 1 year to 2 years when you register customer information.
ATAGO Logger NFC can also be downloaded at the same time.
Trouble scanning the code? Access this link https://www.atago.net/ur/index.php?l=en
Place a fruit, then
press the START button.
Press the
START button
Press the
side button
Press against a fruit,
then press the side button.
The measurements are displayed.
Depending on the variety, there may be a difference between the refractometer
(sugar meter) and the measured value. Please confirm the difference from the value
measured with your refractometer (PAL - 0 of the set when purchasing IR Brix Meter
x Brix Meter) and use the offset function as necessary. (Refer to “Offset Function” )
<LCD Auto Shut-off>
The instrument will turn itself off after 30 seconds of inactivity.
To manually turn it off, hold down the START button for more than 3 seconds.
The temperature difference between
the surface and the inside of the fruit,
and temperature difference between
this instrument and the fruit may affect
the measurement values.
Especially when measuring refrigerated
fruits, be sure to let the fruits acclimate
to the ambient temperature.
The instrument may not measure
correctly when there is water droplets,
dust or scar, and bruising soft spots.
Measure an area larger than 70mm in
diameter with no dents.
Be sure to avoid any spacing between
the fruit and the outer cushion to avoid
the external light interference. If the
cushion is deteriorated, please replace
it with a brand new cushion. (Refer to
“How to change the cushion”)
Example for measurement value: Take
few measurements from the same fruit,
then compute and use the average.
●Acclimate the fruit and this instrument
to ambient temperature.
● Clean the surface of the fruits.
Do not measure the spoiled spots.
● Place the sample stage to the fruit.
● Sugar level or watercore varies
depending on the measured area.
When there is an operation error or malfunction, the
below error message will show with alarm sound or alarm
vibration can for warning.
The battery is low.
Measurement was
taken for fruits with Brix
lower than the
measurement range.
Measurement
was taken when
the unit’s
temperature was
4˚C or lower.
Measured when
the main unit’s
temperature is
exceeding 45℃.
Measurement was
taken when the
fruit’s temperature
was 4˚C or lower.
Measured when
the fruit’s
temperature is
exceeding 45℃.
Measurement was
taken for fruits with
Brix highter than the
measurement range.
The instrument is
faulty.
Replace the batteries. Contact
ATAGO if this error persists.
※Main unit’s temperature
error will preferentially
display when the main unit’s
and fruits’temperatures are
both out of range.
When it is outside of temperature
compensation range.
Digital Hand-held “Pocket” IR Brix Meter
or
1.
Insert a coin in the groove on the battery
 compartment cover. Turn the coin
 counterclockwise to remove the cover.
2. Insert two batteries
3. Align the cover and push it down.
4. Close the battery compartment cover by
  
pushing the cover in with a coin in the groove
  
and turning it clockwise until it stops.
Observe the correct polarity.
Groove
When the
cover is
open
When the
cover is
closed
・About battery indicator
When the battery icon indicates the low power
level , replace both batteries with a brand new
set of AAA alkaline batteries (1.5V).
*Check the expiration dates on batteries before
purchase.
Touch the fruit and do not move.
Beep
Beep
Beep Beep
11.7 
Present 
12.2 
Present
12.4 
Not present
=
12.1
11.7+12.2+12.4
3
(Example)
Note
Measurement was
taken while the sample
stage was not in
contact with fruit.
When correct measurements are
not achievable due to interference
from external light.
There is a temperature
difference between the
fruit and the main unit.
Parts
Contents
・Main unit (with silicone cover) ・・・・・・・・・・・・・・・・・・・・ 1
・Instruction Manual(this book) ・・・・・・・・・・・・・・・・・・・・・ 1
・Inspection Report ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 1
・Cushion RS (for replacement)・・・・・・・・・・・・・・・・・・・・ 3
・AAA alkaline batteries ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 2
※AAA alkaline batteries are included.
Silicon cushion R
Light emitting part
Radiation
temperature
sensor
Cushion RS
Receiver
START button
Battery compartment
Side button
Sample stage
LCD
Menu button
Lanyard hole
Measurement
Cat.No.5462
PAL- HIKARi 12
Instruction Manual
Full When the history of measured data reaches
100. Turn OFF the NFC Function or Delete
Data History.
Flash
Light up
WatercoreWatercore
Not present Present
Watercore
Offset Function
Automatic Temperature Compensation
Cleaning
Storage
This function modifies the measurement value by a constant. Use this function to match the measurement value to the refractometer (Brix meter).
How to set addition/subtraction number [Range:-9.9~9.9]
1. Hold down menu while
it is turned on. 2. Press menu to select
either addition or
subtraction.
(Example) (Example)
No plus sign will be displayed.
Current addition/subtraction number is
displayed and
“-“ will flash.
4.
Enter the addition/subtraction
number. 5.
Press START to confirm the
 addition/subtraction number.
3. Press START
 to confirm.
The
first
digit :
0 to9
The
second
digit :
0 to9
The first digit:
Press menu to
changethe
number.
Press START to
confirm and move
to the next digit.
The second digit:
Press menu to
change the
number.
The entered
addition/subtraction
number will flash first
then remains lit once
confirmed.
Press the START
button or side button
to begin measuring.
・Screen image during
measurement when
offset is on.
The measurement values are temperature dependent. This unit is
equipped with automatic temperature compensation to correct the
readings that are within the range to display measurement value at
20˚C.
The unit displays temperature at the fruit surface.
Safety Precautions
Repair and Warranty
Specifications
The instrument is warranted for one year from the date of purchase.
This warranty is void if the instrument shows evidence of the
following. Send the included batteries as well if they are still in
use. ・Having been disassembled by unauthorized personnel ・
Water damage or having been dropped ・Having been misused
and/or operated outside the environmental specifications ・Leakage
from batteries other than those included with the unit Repair services are
available for a fee after the warranty expires. Contact an ATAGO authorized
service center for service and support.
・Do not aim it at a face when measuring.
・Do not attempt to repair, modify, or disassemble the instrument.
Brix scale
Brix represents the weight of sucrose in 100 grams of sucrose
solution as percentage by weight. When other dissolved solids are
present in the solution, Brix conversion may be applied.
Brix is a measure of the total dissolved solids in a solution and
indicates the combined concentration of all soluble substances,
such as sugar, salt, protein, and acids.
When the measured values are off
①Are there any difference between the fruit, unit, and ambient
temperature?
②Are there any water droplets or soiled area in the measurement section? Is
the fruit spoiled?
③Does the fruit and cushion have a good contact? Especially when
using the side button, is it out of alignment?
④Are there any difference depending on measured section?
①~④ → Refer to “Measurement tips and precautions”
⑤Are there any damages or soil on the light emitting or receiving
section? →Refer to “Cleaning”
If light emitting or receiving section is damaged or soiled, contact
ATAGO.
⑥Is the cushion wet? → Refer to “Cleaning”
Replace cushion to a new one if there is any deterioration. → Refer
to “How to Change the Cushion”
⑦Check the offset feature →Refer to “Offset Function”
Measurement range
Watercore
Resolution
Measurement accuracy
Repeatability
Automatic temperature
compensation range
Ambient temperature range
Measurement time
Backlight
Power supply
International Protection class
Dimensions and weight
Brix 10.0 to 16.0% 
Temperature 5.0 to 45.0˚C
Present or Not present
Measurement fruits Asian Pear
Brix 0.1% Temperature 0.1˚C
Brix
±
1%
* Temperature
±
1˚C
Brix
±
0.5%
5.0~35.0˚C
5 to 35˚C
Approx. 1 second
Two (2) AAA alkaline batteries
IP64
61(W) x 44 (D) x 115 (H)mm, 120g(main unit only)
2108K Printed in Japan
Gasoline
To clean the soiled sample stage, use a wetted
tissue or soft cloth to wipe the area.Completely dry
the cushion area.Avoid using ethyl alcohol. It may
compromise the adhesion on the cushion.
Never splash
water on the
unit.
Do not use organic
solvents (paint thinner,
benzene, gasoline,
etc.) on the plastic
body case.
Do not keep: ●
In a hot and humid place
●
Close to a heater ●
In direct sun light
●
Extreme low temperature
●
Inside a closed car
・Before use, carefully read this instruction manual and
fully understand the function and operation for each part of the
instrument. ・ATAGO is not liable for any or all damages as a result of
use of the instrument for those other than its intended purposes
(measurement of Brix, of fruits). ・Do not hit or protrude the light
emitting or receiving section with a sharp object.
・ATAGO is not liable for any loss and damage caused by the
measurement and use of this instrument. ・Do not expose the
instrument to a rapid change in ambient temperature. ・Do not use the
instrument where there is much dust. ・Do not subject the instrument to
strong vibration. ・Do not place the instrument under anything
heavy. ・If the instrument is dropped or subjected to a strong impact,
contact your supplier for inspection. ・Loosen the battery compartment
cover for air transportation.
menu menu
(While the measurement is
 
displayed.)
WARNING
CAUTION
The backlight stays on for 30 seconds then
turns off after 30 seconds. The backlight is
off when measurements are taken.
ATAGO instruments are rigorously inspected to ensure each
unit meets the highest standards of quality assurance.
*Asian Pear varieties and measurement environment may affect
accuracy.
Headquarters: The Front Tower Shiba Koen, 23rd Floor
2-6-3 Shiba-koen, Minato-ku, Tokyo 105-0011, Japan
TEL: 81-3-3431-1943 overseas@atago.net http://www.atago.net/
TEL: 1-425-637-2107 [email protected]
TEL: 91-22-2833-8038 / 8076 [email protected]
TEL: 662-982-8718-9 [email protected]
TEL: 55 16 3916-6000 customerser[email protected]
TEL: 39 02 36557267 customerser[email protected]
TEL: 86-20-38108256 [email protected]
TEL: 7-812-777-96-96 [email protected]
TEL: 234-707-558-1552 [email protected]
TEL: 7-727-257-08-95 [email protected]
How to Change the Cushion
The Silicon cushion R,Cushion RS and the Silicone Cover
can be replaced.
Please contact ATAGO.
RE-39011 Silicon cushion R
1.Pull off the Silicon cushion R from the sample stage.
2.Fit the Silicon cushion R on to the sample stage.
RE-39012 Cushion RS
(3sets)
1.Remove the old cushion from the sample stage.
2.Peel the paper backing off the sticker. Place the cushion on
the sample stage.
Do not block the radiation thermometer with the cushion.
RE-39415 JORDAN for PAL-HIKARi(Silicon Cover)
Note
1. Press and hold menu then press the
side button while it is turned on. 3. While pressing menu, use the side
button to select ON/OFF.
2. Release the side button while
 continuing to press menu.
Press START or
side button to
begin measuring.
Do not press menu for 5 seconds or more before
pressing the side button. Holding menu will activate
the addition/subtraction number setting.
Note
4.Release finger from menu.
 Confirm setting.
Pressing the side button will switch it between ON/OFF.
(Example)
(Example)
Side button
ON/OFF will flash first then
remains lit once confirmed.
* Keep menu
pressed until
step 3 is
completed.
How to Set Alarm Sound and Alarm Vibrationcan
Buzzer sound and Vibration can be set to alarm when measurement error is displayed or at the beginning and end of measurement.
Buzzer
sound
ON/OFF Buzzer
sound
Vibration
ON/OFF Vibration
Snd Snd Snd Snd
vbr vbr vbr vbr
Switch it between Sound or Vibration
Press and hold menu then press the
start button.
Pressing the start button will switch it
between Buzzer Sound or Vibrationcan.
Maximum number
of data history
Output
100
NFC Forum Type 4 Tag
ISO/IEC 14443 Type A
Output category:
Date Time,Brix[%],Temp[degC],watercore
(e.g.) 2017/08/17 09:30:45, 12.3, 20.4, in
Watercore :
    present…”in”
    not present…”-”
For default :  Press the side button while setting up the Off-Set feature.

This manual suits for next models

1

Other ATAGO Measuring Instrument manuals

ATAGO PAL-17S User manual

ATAGO

ATAGO PAL-17S User manual

ATAGO MASTER Series User manual

ATAGO

ATAGO MASTER Series User manual

ATAGO PALETTE Series User manual

ATAGO

ATAGO PALETTE Series User manual

ATAGO PAL-03CS User manual

ATAGO

ATAGO PAL-03CS User manual

ATAGO PAL-55S User manual

ATAGO

ATAGO PAL-55S User manual

ATAGO PAL-Easy ACID3 User manual

ATAGO

ATAGO PAL-Easy ACID3 User manual

ATAGO PAL-Easy ACID2 User manual

ATAGO

ATAGO PAL-Easy ACID2 User manual

ATAGO PAL-89S User manual

ATAGO

ATAGO PAL-89S User manual

ATAGO PAL-19S User manual

ATAGO

ATAGO PAL-19S User manual

ATAGO PRM-2000 A User manual

ATAGO

ATAGO PRM-2000 A User manual

ATAGO PAL-Easy ACID21 User manual

ATAGO

ATAGO PAL-Easy ACID21 User manual

ATAGO PAL-66S User manual

ATAGO

ATAGO PAL-66S User manual

ATAGO PAL-54S User manual

ATAGO

ATAGO PAL-54S User manual

ATAGO PAL-37S User manual

ATAGO

ATAGO PAL-37S User manual

ATAGO PAL-Grape Must User manual

ATAGO

ATAGO PAL-Grape Must User manual

ATAGO PAL-22S User manual

ATAGO

ATAGO PAL-22S User manual

ATAGO Pen-Honey User manual

ATAGO

ATAGO Pen-Honey User manual

ATAGO PAL-HIKARi 3 MINi User manual

ATAGO

ATAGO PAL-HIKARi 3 MINi User manual

ATAGO PAL-08S User manual

ATAGO

ATAGO PAL-08S User manual

ATAGO PAL-Grape Must KMW User manual

ATAGO

ATAGO PAL-Grape Must KMW User manual

ATAGO PAL-36S User manual

ATAGO

ATAGO PAL-36S User manual

ATAGO PAL-HIKARi 7 User manual

ATAGO

ATAGO PAL-HIKARi 7 User manual

ATAGO PRM-100a User manual

ATAGO

ATAGO PRM-100a User manual

ATAGO PAL-05S User manual

ATAGO

ATAGO PAL-05S User manual

Popular Measuring Instrument manuals by other brands

HP 436A Operating and service manual

HP

HP 436A Operating and service manual

Faro FOCUS3D X 130 user manual

Faro

Faro FOCUS3D X 130 user manual

Burster RESISTOMAT 2408 manual

Burster

Burster RESISTOMAT 2408 manual

Evoqua WALLACE & TIERNAN DEPOLOX 5 E instruction manual

Evoqua

Evoqua WALLACE & TIERNAN DEPOLOX 5 E instruction manual

National Instruments PXIe-4163 Getting started guide

National Instruments

National Instruments PXIe-4163 Getting started guide

PASCO SF-9568A instruction sheet

PASCO

PASCO SF-9568A instruction sheet

GE AED Pro Service manual

GE

GE AED Pro Service manual

Burkert 8222 ELEMENT NEUTRINO operating instructions

Burkert

Burkert 8222 ELEMENT NEUTRINO operating instructions

VOLTCRAFT BS-2.0/1m operating instructions

VOLTCRAFT

VOLTCRAFT BS-2.0/1m operating instructions

Eagle Tree Systems Pro user manual

Eagle Tree Systems

Eagle Tree Systems Pro user manual

Hongda USA AT2150/B series user guide

Hongda USA

Hongda USA AT2150/B series user guide

Anaheim Scientific E200 user manual

Anaheim Scientific

Anaheim Scientific E200 user manual

Kobold APS-Z operating instructions

Kobold

Kobold APS-Z operating instructions

Alecto AQ30 user manual

Alecto

Alecto AQ30 user manual

IDEAL 61-772 instruction manual

IDEAL

IDEAL 61-772 instruction manual

Bosch Zamo manual

Bosch

Bosch Zamo manual

Spectrasensors 2000 Series Operator's manual

Spectrasensors

Spectrasensors 2000 Series Operator's manual

Calculated Industries SCALE MASTER PRO 6028 user guide

Calculated Industries

Calculated Industries SCALE MASTER PRO 6028 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.