Atal EPD-TRHP-INT User manual

2
Table of contents
Introduction......................................................................................................................................................3
General safety rules .....................................................................................................................................3
Device description and important notices...................................................................................................4
Getting started .................................................................................................................................................6
What is needed for operation......................................................................................................................6
Mounting the device....................................................................................................................................6
Device settings .............................................................................................................................................7
Checking functions.......................................................................................................................................8
Device setup .....................................................................................................................................................9
Setup using web interface............................................................................................................................9
Setup using TSensor software....................................................................................................................19
Factory defaults .........................................................................................................................................20
Communication protocols..............................................................................................................................22
Website ......................................................................................................................................................22
SMTP –sending e-mails .............................................................................................................................22
SNMP .......................................................................................................................................................22
Modbus TCP ...............................................................................................................................................25
SOAP .......................................................................................................................................................26
Syslog .......................................................................................................................................................28
SNTP .......................................................................................................................................................28
Troubleshooting .............................................................................................................................................29
I forgot the device IP address ....................................................................................................................29
I cannot connect to the device...................................................................................................................29
I forgot the password for setup .................................................................................................................29
Factory defaults .........................................................................................................................................29
Display is off ...............................................................................................................................................30
Device error states.....................................................................................................................................31
Technical specifications..................................................................................................................................32
Dimensions.................................................................................................................................................32
General parameters ...................................................................................................................................34
Measured values........................................................................................................................................35
Temperature measurement.......................................................................................................................36
Relative humidity measurement................................................................................................................36
Atmospheric pressure measurement ........................................................................................................37
Computed quantities .................................................................................................................................37
Operating terms.........................................................................................................................................39
End of operation ........................................................................................................................................40
Technical support and service....................................................................................................................40
Preventive maintenance ............................................................................................................................40
Optional accessories.......................................................................................................................................41

3
Introduction
This chapter provides basic information about device. Before starting please read
this manual carefully.
The Web Sensor devices are designed for measurement of temperature, relative humidity
and atmospheric pressure in air without aggressive substances. Measured quantities are
according device type. Devices with relative humidity measurement can show one of
computed quantities: dew point temperature, absolute humidity, specific humidity, mixing
ratio and specific enthalpy. Temperature units are °C or °F. Pressure units are hPa, PSI,
inHg, mBar, oz/in2, mmHg, inH2O and kPa. Communication interface of Web Sensors is
Ethernet. Device types:
Type
Temperature
Relative humidity
Pressure
Computed quantity
EPD-T-INT
EPD-TRH-
INT
EPD-TRHP-
INT
EPD-P-INT
EPD-TRH(P)
EPD-T
EPD-TRHP
Web Sensor EPD-xxx-xxx-P devices are designed for measurement in compressed air up
to 25 bars. The removable probe is integral part of the device. It is not possible to
interchange probe between devices. Probe has connector with protection IP67.
Models marked EPD-xxx-Z are custom-specified devices. Description of these devices is
not included in this manual.
General safety rules
The following summary is used to reduce the risk of injury or damage the device.
To prevent injury, please follow instructions.
The device can be services only by a qualified person. The device contains no
serviceable parts inside.
Don’t use the device, if it doesn’t work correctly. If you think, that the device is
not working correctly, let check it by qualified service person.
Chapter
1

4
It’s forbidden to use the device without the cover. Inside the device can be a dangerous
voltage and may be risk of electric shock.
Use only the appropriate power supply adapter according to manufacturer specifications
and approved according to relevant standards. Make sure, that the adapter does not have
damaged cables or covers.
Connect the device only to network parts approved according to relevant standards.
Connect and disconnect the device properly. Don’t connect or disconnect Ethernet cable
or probes, if the device is powered.
The device may be installed only in prescribed areas. Never expose the device to higher or
lower temperatures than is allowed. The device has not improved resistance to moisture.
Protect it from dripping or splashing water and do not use at areas with condensation.
Devices are not designed for locations with chemically aggressive environment.
Temperature and humidity sensors must not be exposed to direct contact with water or
other liquids. It is not allowed to remove the sensor cover to avoid any mechanical damage
of the sensors.
Before you removing probe of the Web Sensor EPD-xxx-xxx-P, make sure that pressure in
a pressure chamber and ambient pressure are equal.
Don’t use device in explosive environments.
Don’t stress the device mechanically.
Device description and important notices
This chapter contains information about basic features. Also there are
important notices concerning to functional safety.
Measured values can be displayed on LCD display or can be read using an Ethernet
connection. The following formats are supported:
Web pages with user changeable look and XML files
Modbus TCP protocol
SNMPv1 protocol
SOAP protocol
The device can also be used to check measured values and if the limit is exceeded, device
sends warning messages. Possible ways to sending warning messages:
Sending e-mails up to 3 e-mail addresses
Sending SNMP traps up to 3 configurable IP addresses
Displaying the alarm status on web page
Sending messages to Syslog server
The device setup can be made by the TSensor software or web interface. TSensor software
can be free downloaded from the manufacturer’s website. Also you will find there latest
firmware for your device. Do not upload to your device firmware which is not designed for
it. Unsupported firmware can damage your device.

5
Device does not support powering over Ethernet cable (PoE). PoE splitter must be used.
Compatible PoE splitter can be purchased as optional accessories. Splitter must have 12V
output with approximately 1W.
Reliability of warning messages delivering (e-mail, trap, syslog), depends on
actual availability of necessary network services. The device should not be used
for critical applications, where malfunction could cause to injury or loss of
human life. For highly reliable systems, redundancy is essential. For more
information please see standard IEC 61508.
Never connect the device directly to the Internet. If it is necessary connect the
device to the Internet, properly configured firewall must be used. Firewall can
be partially replaced by the NAT.
Table of contents