Notice technique complète sur www.atim.com
FRQIG_ARM-IOD-LP
Page4/4
–Put the STRAP 1 (ON) and the STRAP 2 (ON)
–Put back the battery
–The LED is flashing rapidly
–Disconnect the battery
For initializing the modem (frequency and modem address selection):
–Disconnect the battery
–Run down the remaining voltage in shorting circuit the + and the - of the battery connector
–Remove the STRAP 2 (OFF)
–Put the STRAP 1 (ON)
–Put back the battery
–The LED is flashing: 1s ON / 1s OFF, during 35s
–If the radio modem receive a modbus frame on a frequency from its frequency table (usable radio frequency : channel 1; 3; 5;
7; 9; D; F; see table frequency, Ch2,3)), it records the selected frequency and the sent address. There is no answer to request, so
the LED is flashing, 200ms ON and 2s OFF.
–After 35s, the modem takes the default configuration and the LED is lighting: 200ms ON / 5s OFF
Default configuration:
–Radio frequency: channel 1
–Modbus address: last octet of the serial number
ARM-IO configuration by webpage:
–Select in the radio tab: « radio baud rate »: 9600bps
–Select in the setup tab: « Wake up sleeping slave »
ARM-IO configuration by AT command:
–Register S04 Hexadecimal Value: 20
–Register S09 Hexadecimal Value: 12
–Register S36 Hexadecimal Value: AF
–Register S37 Hexadecimal Value: 00
5. CONFIGURATION EN MODE MIROIR
The modem configuration can be made in manufactory.
For erasing the modem configuration:
–Disconnect the battery
–Run down the remaining voltage in shorting circuit the + and the - of the battery connector
–Put the STRAP 1 (ON) and the STRAP 2 (ON)
–Put back the battery
–The LED is flashing rapidly
–Disconnect the battery
For initializing the modem (modem address and frequency selection):
–Disconnect the battery
–Run down the remaining voltage in shorting circuit the + and the - of the battery connector
–Put the STRAP 1 (ON) and the STRAP 2 (ON)
–Connect the logical input INP1 to the ground according to the cycle time desired:
-INP1 disconnected : cycle time 1mn
-INP1 connected to the ground: cycle time 15mn
–Put back the battery
–La LED is flashing rapidly: 200ms ON 200ms OFF
–The modem is initialized in master mirror mode with the default address corresponding to the last octet of the MAC address.
–Disconnect the battery
–Run down the remaining voltage in shorting circuit the + and the - of the battery connector
–Configure the slave ARM-D Modem or slave ARM-X mirror mode. Local address=ARM-IO-LP. Destination address= ARM-IOD-LP
–Take off the STRAP 2 (OFF)
–Put back the battery
–The ARM-IO-LP will automatically search the slave modem. The LED lights as soon as the emission of a radio frame and the
answer to its request on a channel.