ZCM-V2
Zone Controller Pro Install Sheet
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
Introduction
The ZCM-V2 Zone Controller Pro is an analog gateway for Atlas Sound
IP paging systems. This model is compatible with Atlas Sound's
ControlKom©and Singlewire’s InformaCast©software. The ZCM-V2
provides a line level output to connect to Atlas Sound commercial
amplifiers and an 8Ω, 25V, 70.7V amplified output to drive small analog
speaker zones. It also includes 2 GPI Inputs, 2 GPI Outputs and
Microphone input for talk back applications. Power can be supplied via
plug-in transformer (IPS-PSU) or by 802.3af compliant PoE network
switches. All control features of the ZCM-V2 are software controlled.
Functionality
Once connected to a network and powered, the ZCM-V2 will boot up
and obtain an IP address from a DHCP server on the network. Next,
the unit will listen for an SLP broadcast from InformaCast / ControlKom
software telling the unit where the service is running on the network.
Once the ZCM-V2 identifies the software’s location, it will request
the InformaCastSpeaker.cfg file and register. The MAC address of the
ZCM-V2 will then show in the ‘Unidentified Speakers” page in the
software. Please refer to the installation manual of the software for
additional configuration settings.
After the module has registered with the software, its HTTP page can
be accessed by navigating to its IP address with any browser. This page
will show its current firmware version and registration information.
Use Only if 802.3 af
Compliant POE Switch
Not Available
Input / Output
1601 Jack McKay Blvd.
Ennis, TX 75119
800.876.3333
AtlasSound.com
Contact Closure In / Out
Positive Tip Polarity
12VDC 1 AMP min
ZCM-V2 Zone Controller
GPI–I 1
GPI–I 2
GPI–O 1
GPI–O 2
3.3VDC
GND
MIC IN
GND
8Ω
70.7V
25V
8Ω / 25V /
70.7V COM
LINE +
LINE / COM
Remove
For 8Ω
1 2 3456 7 8 9 10
Microphone Input1.
82. ΩJumper (Remove this Jumper for 8ΩOperation)
83. ΩSpeaker Output
70.7V Speaker Output4.
25V Speaker Output5.
86. Ω, 25V, and 70.7V Speaker Output COM
Line Level Output7.
GPI Inputs8.
GPI Outputs9.
DC Output and COM for Use with GPI I/O10.
2/4
AtlasSound.com
TELEPHONE: (800) 876-3333
FAX (800) 765-3435
©2011 Atlas Sound L.P. All rights reserved. Atlas Sound is a trademark of Atlas Sound L.P. All other trademarks are the property of their respective owners. All specs are subject to change without notice. ATS003980 RevA 1/11
ZCM-V2
Zone Controller Pro Install Sheet
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
GPI Interface
GPI Inputs:
GPI Inputs 1 and 2 are used to trigger events in the ControlKom and Informacast software packages. Refer to software manuals for functionality.
GPI Outputs:
Via the InformaCastSpeaker.cfg file the GPIO’s can be configured for special operations.
To activate the GPI Out closure when audio is playing, use a tag like this:
<GPIO while_audio_output="1x" />
The first digit controls GPI Out 1; the second controls GPI Out 2.
"1" means to close it when audio is playing, open it otherwise.
"0" means to open it when audio is playing, close it otherwise.
"x" means the that GPI Out is not affected by audio playing.
Example:
<InformaCastSpeakerConfiguration>
<Servers registration-interval="5">
<InformaCast url="http://server_ip_address:8081/InformaCast/admin?cmd=spkr"/>
</Servers>
<Firmware file="ipsl_EL020b17.bin"/>
<PriorityBootFirmware file="ipsl_EL020b17.bin"/>
<PriorityFirmware file="ipse_E292b17.bin"/>
<FPGAFirmware file="fpga1074.bin"/>
<GPIO while_audio_output="1x" />
</InformaCastSpeakerConfiguration>
Pin Out for GPI I/O
"J3" shows the Pin out for the GPI I/O:
1Input 1 +
2Input 1 –
3Input 2 +
4Input 2 –
5Output 1+
6Output 1-
7Output 2+
8Output 2 –
9+ 3.3VDC
10 GND
3/4
AtlasSound.com
TELEPHONE: (800) 876-3333
FAX (800) 765-3435
©2011 Atlas Sound L.P. All rights reserved. Atlas Sound is a trademark of Atlas Sound L.P. All other trademarks are the property of their respective owners. All specs are subject to change without notice. ATS003980 RevA 1/11
ZCM-V2
Zone Controller Pro Install Sheet
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
GPI Applications
Below is an application that will isolate the audio output from the amplifier until a broadcast is active.
Mounting
One or Two Zone Controller Pro units can be rack mounted side by side via a 2RU face plate. This 2RU face plate is included with the ZC1PRO and the
ZC2PRO systems. The faceplat may be purchased separately, using part number ZCM-V2FP.
Or wall mount via the 2 keyholes
Use Only if 802.3 af
Compliant POE Switch
Not Available
Input / Output
1601 Jack McKay Blvd.
Ennis, TX 75119
800.876.3333
AtlasSound.com
Contact Closure In / Out
Positive Tip Polarity
12VDC 1 AMP min
ZCM-V2 Zone Controller
GPI–I 1
GPI–I 2
GPI–O 1
GPI–O 2
3.3VDC
GND
MIC IN
GND
8Ω
70.7V
25V
8Ω / 25V /
70.7V COM
LINE +
LINE / COM
Remove
For 8Ω
TO AMP INPUT PLUS (+)
TO AMP INPUT COM (–)
4/4
AtlasSound.com
TELEPHONE: (800) 876-3333
FAX (800) 765-3435
©2011 Atlas Sound L.P. All rights reserved. Atlas Sound is a trademark of Atlas Sound L.P. All other trademarks are the property of their respective owners. All specs are subject to change without notice. ATS003980 RevA 1/11
ZCM-V2
Zone Controller Pro Install Sheet
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
General Specifications
Rack Space 2RU (3.5") If ZCM-V2FP is Used.
Weight ZCM-V2 Module – 5 lbs
ZC1PRO System – 6 lbs
ZC2PRO System – 11 lbs
Height 2.56" (65mm) - ZCM-V2 Module
Width 8" (203mm) - ZCM-V2 Module
Depth 10" (254mm) - ZCM-V2 Module
Mounting 2 Key Holes (7" Span) for Wall Mount
Rack Plate (Included)
Amplifier / Control Specifications
Power Rating 9 Watts RMS into an 8ΩLoad with 12VDC Input
Inputs RJ-45 Female on PCB
(Accessible from Rack Ear Attachment Side)
Outputs 600Ω, 8Ω, 25V, and 70.7V
Power Source IEEE 802.3af Compliant POE Network Switches / Local 12VDC – 18VDC PSU
Network Control Multicast Enabled Networks
GPI Specifications
Relay Output 50V at 500mA Max
Input Minimum 1mA to Run on 50V Max
Microphone Specifications (Optional)
Sensitivity -35 (±4dB)
(0db = 1V/pa, 1kHz)
Impedance Less than 2.2k
Directivity Omnidirectional
Frequency 20Hz – 20kHz
Max. Operation Voltage 10V
Standard Operation Voltage 2V
Current Consumption Max. 0.5 mA
Sensitivity Reduction Within -3dB @ 1.5V
S/N Ratio More than 62dB

Popular Gateway manuals by other brands

Siemens SIMATIC FDE Gateway V1.1 Equipment manual

Siemens

Siemens SIMATIC FDE Gateway V1.1 Equipment manual

HMS Networks Intesis INMBSDAL0640500 Installation sheet

HMS Networks

HMS Networks Intesis INMBSDAL0640500 Installation sheet

Weidmüller IE-GW-MB-2TX-1RS232/485 Hardware installation guide

Weidmüller

Weidmüller IE-GW-MB-2TX-1RS232/485 Hardware installation guide

schmersal SD-I-U Series Mounting and wiring instructions

schmersal

schmersal SD-I-U Series Mounting and wiring instructions

ABB COM 610 *2.1 user guide

ABB

ABB COM 610 *2.1 user guide

CBN CH7284E user guide

CBN

CBN CH7284E user guide

Fujitsu UTY-VBGX instruction manual

Fujitsu

Fujitsu UTY-VBGX instruction manual

WURM CMD300 manual

WURM

WURM CMD300 manual

Gigabyte EL-30 quick start guide

Gigabyte

Gigabyte EL-30 quick start guide

ZyXEL Communications P-660H Series quick start guide

ZyXEL Communications

ZyXEL Communications P-660H Series quick start guide

Juniper SRX 5800 Replacing

Juniper

Juniper SRX 5800 Replacing

Huawei IAD108A user manual

Huawei

Huawei IAD108A user manual

DIGITAL YACHT NavLink quick start guide

DIGITAL YACHT

DIGITAL YACHT NavLink quick start guide

AirLink Communications Host RJ-11 user guide

AirLink Communications

AirLink Communications Host RJ-11 user guide

NetComm CloudMesh NL19MESH manual

NetComm

NetComm CloudMesh NL19MESH manual

Ejoin ACOM5 Series user manual

Ejoin

Ejoin ACOM5 Series user manual

Kuhnt WLL550Pro operating manual

Kuhnt

Kuhnt WLL550Pro operating manual

Philips Dynalite DDNG100BT installation guide

Philips

Philips Dynalite DDNG100BT installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.