Atmos ACD 03 User manual

Operation manual - EN
www.atmos.eu EN - 1
ACD03/04
Operation
manual

Operation manual - EN
www.atmos.eu
ACD03/04

Operation manual - EN
www.atmos.eu EN - 3
ACD03/04
CONTENTS
1. SOFTWARE VERSION 9
2. INTRODUCTION 9
3. DESCRIPTION 10
Basic division of ATMOS ACD 03 and ATMOS ACD 04 controllers 10
Variants of ATMOS ACD 03 and ATMOS ACD 04 controllers 11
ATMOS ACD 03 - Controller inserted into boiler panel 11
ATMOS ACD 04 - ATMOS ACD 04 - Controller installed in boiler instrument hood (in factory) 11
4. INSTALLATION IN BOILER 13
ATMOS ACD 03 13
ATMOS ACD 04 14
Recommended sensors installation 15
5. CONNECTION 17
Connection terminals (description) on the back side of the controller 17
Terminal block and connectors 17
Overview of connection terminals of ACD 03/04 controller 18
6. INSTALLATION GUIDE (WIZARD) (first start of the controller) 20
Installation Guide 20
Key to define hydraulic diagram number 25
7. BUTTONS AND INFORMATION ON THE SCREEN 27
ATMOS ACD 03/04 controller display 27
8. OPERATING MODES MENU 46
Basic description of operating modes 48
Standby - permanent working mode 49
Setback -
permanent working mode 50
Comfort -
permanent working mode 51
Summer -
permanent working mode 52
Auto (time program) -
permanent working mode 53
Visit - temporary working mode 54
Absence - temporary working mode 56
Holidays - temporary working mode 57
9. TEMPERATURE SETTING MENU 58
10. SETTING MENU 59
Date, Time 60
Setting the current time 60
Setting the current date 60
Setting automatic switching to summer time 61
Time calibration setting (seconds/week) 61
The function allows you to set the time measurement deviation setting (number
of seconds per week). 61
Time source 62
Time programs for Auto mode 63
Weekly program selection (week A / week A, B, C) 64
Time programs setting 65
Weekly time program overview 66
Daily time program overview 66

Operation manual - EN
www.atmos.eu
EN - 4
ACD03/04
Copying the day 68
Copying weekly heating circuit program 69
Limitations (link to other parameters): 70
Resetting time programs to their default state 71
Hydraulics 72
Menu - Hydraulic diagram overview: 72
Menu - Communication: 76
Menu - Function configuration: 85
Terminal assignment 86
Terminal change 88
Release the clamp 89
Boiler type designation 90
Controlled boiler 90
Boiler submenu- definition of additional functions for the boiler: 91
Accumulation tank submenu- overview of defined elements: 96
Domestic water DHW (2) submenu - overview of defined elements: 99
Heating circuit 1 function submenu: 105
Heating circuit 2 function submenu: 112
Heating circuit 3 function submenu: 119
Heating circuit 4 function submenu: 126
Sources submenu: 127
Solar heating submenu: 131
General setting submenu - definition of additional functions: 133
Temperature sensors submenu - definition of additional sensors 135
Menu - Output test: 137
Menu - Actuator direction of rotation: 138
Hydraulic diagram 139
Key to define hydraulic diagram number 140
Overview of connection terminals of ACD 03/04 controller 142
Examples of hydraulic diagrams: 144
Not controlled boiler connected without accumulation tank 144
Hydraulic diagram: 11033 Example 1 145
Not controlled boiler connected with accumulation tanks 146
Hydraulic diagram: 17033 Example 2 147
Controlled boiler connected without accumulation tank 148
Hydraulic diagram: 33033 Example 3 149
Controlled boiler connected without accumulation tank 150
Hydraulic diagram: 33833 Example 4 151
Controlled boiler connected with accumulation tanks 152
Hydraulic diagram: 37833 Example 5 153
Controlled boiler (GSE) connected with accumulation tank 154
Hydraulic diagram: 57033 Example 6 155
Controlled boiler (GSE) connected with accumulation tank 156
Hydraulic diagram: 57833 Example 7 157
Controlled boiler (GSE) connected with accumulation tanks (into series) 158
Hydraulic diagram: 55833 Example 8 159
Controlled boiler with burner connected without accumulation (buffer) tank 160
Hydraulic diagram: 23333 Example 9 161

Operation manual - EN
www.atmos.eu EN - 5
ACD03/04
Controlled boiler with burner connected with accumulation (buffer) tank 162
Hydraulic diagram: 27833 Example 10 163
Controlled boiler with burner connected without accumulation (buffer) tank 164
Hydraulic diagram: 23033 Example11 165
Controlled boiler with burner connected with accumulation (buffer) tank 166
Hydraulic diagram: 27833 Example 12 167
Controlled combined boiler (with modification for burner) connected without accumulation tank
168
Hydraulic diagram: 63033 Example 13 169
Controlled combined boiler (with modification for burner) connected with accumulation tank
170
Hydraulic diagram: 67833 Example 14 171
Controlled combined boiler (SP) connected without accumulation tank 172
Hydraulic diagram: 63003 Example 15 173
Not controlled combined boiler (SP) connected with accumulation (buffer) tank 174
Hydraulic diagram: 16003 Example 16 175
Controlled combined boiler (SP) connected with accumulation tanks (parallel) 176
Hydraulic diagram: 67003 Example 17 177
Controlled combined boiler (GSP) connected with accumulation tanks (into series) 178
Hydraulic diagram: 77833 Example 18 179
Controlled boiler connected with accumulation tank and solar system 180
Hydraulic diagram: 37533 Example 19 181
Controlled boiler with burner connected with accumulation (buffer) tank and solar system
182
Hydraulic diagram: 27533 Example 20 183
Controlled boiler with burner connected with accumulation (buffer) tank and solar system
184
Hydraulic diagram: 27533 Example 21 185
Controlled boiler connected with accumulation tank
and external boiler without built-in pump 186
Hydraulic diagram: 37233 Example 22 187
Controlled boiler connected with accumulation tank and heat pump 188
Hydraulic diagram: 37003 Example 23 189
Parameters:
System 190
Boiler 200
Automatic wood ignition 210
Accumulation tank 216
Sources 221
Heating circuit 1 / 2 / 3 / (4) 225
DHW 236
General function 242
Solar heating 243
Sensors calibration 250
Sweeper 251
Alarms 253
Alarm overview 254
Password 246

Operation manual - EN
www.atmos.eu
EN - 6
ACD03/04
11. INFORMATION MENU 257
12. OVERVIEW OF MENUS AND THEIR PARAMETERS 259
SYSTEM menu 259
BOILER menu 260
ACCUMULATION TANK menu 261
HEATING CIRCUIT 1 / 2 / 3 / (4) menu 262
DHW menu 261
SOURCES menu 263
GENERAL FUNCTION menu 263
SOLAR HEATING menu 263
13. ROOM UNITS 266
ARU5 Room unit (sensor) 266
ARU10 Room unit with temperature correction 268
ARU30 Room unit with touch screen 276
14. TECHNICAL PARAMETERS 289
GARANTIEBEDINGUNGEN 292

Operation manual - EN
www.atmos.eu EN - 7
ACD03/04
1. SOFTWARE VERSIONU
2. INTRODUCTION
3. DESCRIPTION
4. INSTALLATION IN BOILER
5. CONNECTION
6. INSTALLATION GUIDE (WIZARD)
8. OPERATING MODES MENU
7. BUTTONS AND INFORMATION ON THE SCREEN
9. TEMPERATURE SETTING MENU
10. SETTING MENU
Hydraulic diagrams
System
Boiler
Automatic wood ignition
Accumulation tank
DHW
Sources
Alarms
Heating circuit 1 / 2 / 3 / (4)
Password
Solar heating
Sweeper
Sensors calibration
General function
11. INFORMATION MENU
12. OVERVIEW OF MENUS AND THEIR PARAMETERS
13. ROOM UNITS
14. TECHNICAL PARAMETERS

Operation manual - EN
www.atmos.eu
EN - 8
ACD03/04

Operation manual - EN
www.atmos.eu EN - 9
ACD03/04
1. SOFTWARE VERSION
This operation manual can be used from the Program version (VERSION PRG)… AC16D 1.05
The program version is displayed at the end of the Information under the button i-
System information.
2. INTRODUCTION
Equithermal controllers ATMOS ACD 03 and ATMOS ACD 04 with touch screen are designed
for comfortable control of the hot-water system of the heated building. The control of the controller
is very simple and intuitive thanks to the touch screen.
The controller contains functions for direct control of the boiler, boiler circuit, three heating cir-
cuits, domestic hot water (DHW), solar, etc...
For correct operation, the controller must be precisely set up via the installation guide (according
to the selected hydraulic diagram).
2. Introduction 1. Software version

Operation manual - EN
www.atmos.eu
EN - 10
ACD03/04
3. DESCRIPTION
Basic division of ATMOS ACD 03 and ATMOS ACD 04 controllers
4 - Slot for SD card
5- ACD 03 regulator attaching mechanism into panel opening
6- ACD 03/04-B relay module (power part)
7- FAN connector for fan speed sensing (special function)
8- 1, 2, 3 connectors for connection of control outputs (0 - 10 V, GND, PWM - pump control signal)
9- Sensor connectors
10 - Power parts connectors (pumps, actuators, etc.)
1 - Screw for the attachment of the ACD 03 controller to the boiler panel
2- Touch screen
3- Openings for attachment of the ACD 04 regulator in the boiler instrument hood
4
1
105
2
6 67
3
98
2
ATMOS ACD 03 ATMOS ACD 04
3. Description

Operation manual - EN
www.atmos.eu EN - 11
ACD03/04
Variants of ATMOS ACD 03 and ATMOS ACD 04 controllers
The ACD 03 and ACD 04 controllers differ in their installation box design:
The control functions of both controllers are the same.
ATMOS ACD 03 - Controller inserted into boiler panel
The ACD 03 controller is designed to be inserted into the boiler panel after breaking out the
readyprepared opening (factory prepared) for ACD 03 controller (dimension 92 x 138 mm).
The controller can also be inserted into a special SWS 18 box intended for wall installation.
ATMOS ACD 04 - Controller installed in boiler instrument hood (in
factory)
The ACD 04 controller is designed to be screwed into the instrument hood of the boiler
(4x M4).
It is delivered directly from the factory and the boiler does not contain classical controls like
thermometer and thermostats. The boiler panel is designed for the installation of theACD 04 controller
only.
3. Description

Operation manual - EN
www.atmos.eu
EN - 12
ACD03/04
ÚVOD
Both controllers consist of two parts. ATMOS ACD 03A / ACD 04A controller and the ACD
03/04-B relay module. The module is designed to control individual power parts of the heating sys-
tem such as pumps, actuators, etc..
On the back of the controller there are connectors for sensors (ATMOS ACD 03A / ACD 04) and
power parts (ACD 03/04-B).
SCS34 set of connectors is used to connect sensors and power parts (code: S0105).
There is an SD card slot on the side of the controller to update the software and back up the settings.
ACD 03/04-B relay module (power part) and
description of connection terminals on the back
of the controller
SCS34 set of connectors to connect sensors and
power parts
ACD 03/04-B relay module (power part) and
description of connection terminals on the back
of the controller
Slot for SD card
3. Description

Operation manual - EN
www.atmos.eu EN - 13
ACD03/04
4. Installation in boiler
4. INSTALLATION IN BOILER
ATMOS ACD 03
Breaking the opening and installation of the regulator into the ATMOS boiler hood panel.
Break the opening by hand
Example of the connection of individual
connectors
Broken opening (92 x 138 mm)
Fastening (tightening) the controller to the
boiler panel (tighten by rotating clockwise)

Operation manual - EN
www.atmos.eu
EN - 14
ACD03/04
ATMOS ACD 04
Installation / removal of the ACD 04 controller into / from the boiler hood.
Special ATMOS instrument hood for ACD 04 controller with four M4 screws.
Attention - do not overtighten (right-hand
thread)
Installation of the controller on four M4 screws
Controller installed in the boiler instrument
hood
4. Installation in boiler
Example of sticking a label on the instrument
hood

Operation manual - EN
www.atmos.eu EN - 15
ACD03/04
Recommended sensors installation
WF boiler temperature sensor in the boiler pocket, the sensor is added to other capillaries from the
thermostats and thermometer of the original electromechanical regulation of the boiler.
The sensor must be placed as far (deep) as possible in the boiler pocket for accurate temperature
sensing!!!
The AGF flue gas sensor attached to the boiler flue gas duct (DCxxS, DCxxSX, DCxxGS, CxxS(T)),
the sensor is added to the flue gas thermostat capillary of the original electromechanical regulation
of the boiler.
This sensor must be covered with insulation!!!
The AGF flue gas sensor attached to the boiler flue gas duct with tube heat exchanger (DCxxGSE,
DCxxGSX, DCxxDG), the sensor is added to the flue gas thermostat capillary of the original
electromechanical regulation of the boiler.
This sensor must be covered with insulation!!!
4. Installation in boiler

Operation manual - EN
www.atmos.eu
EN - 16
ACD03/04
PF temperature sensor in the upper part of the accumulation tank or SF temperature sensor in the
combined DHW heater inserted as deep as possible in the pocket.
The PF sensor must always be at least 10 cm below the pipe entry into the tank.
It is not recommended to place (attach) the sensor on the pipe due to the proper functioning of the
controller!!!
FPF temperature sensor in the lower part of the accumulation tank inserted as deep as possible in the
pocket.
The FPF sensor must always be at least 10 cm above the pipe entry (outlet) to the tank.
It is not recommended to place (attach) the sensor on the pipe due to the proper functioning of the
controller!!!
Additional sensor behind the mixing valve measuring the temperature of water flowing into the
heating circuit.
4. Installation in boiler

Operation manual - EN
www.atmos.eu EN - 17
ACD03/04
5. CONNECTION
According to the selected hydraulic connection of the boiler (see diagrams on page 123), connect
the necessary sensors to the controller connectors no. 1 to 34 and the power parts of the heating
system to the connectors no. 35 to 70.
Connection terminals (description) on the back side of the controller
Terminal block and connectors
View of controller with connectors
Example of wiring
Upper connectors for power parts
Lower connectors for sensors
Attention - connectors are equipped with pins
preventing them from being misplaced on the
terminal block
230VAC/ 50-60Hz/ 2.8W/ 5VA IP20
Itotal max.: 6A (fuse T6.3A) Icontact max.: 4(4)A
230VAC/ 50-60Hz/ 2.8W/ 5VA IP20
Itotal max.: 6A (fuse T6.3A) Icontact max.: 4(4)A
ACD 03A
ACD 04A
sn: 1003
sn: 1135
LL
ININ
PEPE
LL
VA1VA1
NN
FANFAN
LL
65
65
66
66
67
67
68
68
69
69
70
70
FAN
FAN
GNDGND
PWMPWM
10V10V
AA
GNDGND
12V12V
BB
AA
GNDGND
12V12V
BB
GNDGND
GNDGND
GNDGND
GNDGND
VF2VF2
AGFAGF
PFPF
VI1VI1
GNDGND
GNDGND
GNDGND
GNDGND
VI2VI2
VI3VI3
VI4VI4
VI5VI5
34
34
33
33
32
32
31
31
30
30
29
29
28
28
27
27
26
26
25
25
24
24
23
23
22
22
21
21
20
20
19
19
18
18
17
17
16
16
15
15
14
14
13
13
12
12
11
11
AFAF
GNDGND
GNDGND
GNDGND
WFWF
SFSF
VF1VF1
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
sn: 1003
sn: 1135
5. Connection

Operation manual - EN
www.atmos.eu
EN - 18
ACD03/04
Overview of connection terminals of ACD 03/04 controller
Terminal
Abbreviation
Terminal name - Description - Special INPUTINPUT Log. Sensor type, note
FAN FAN fan speed sensing (special function) input --
Terminal
Abbreviation
Terminal name - Description - Special OUTPUTSOUTPUTS Log. Sensor type, note
1 10 V 0 - 10 V - voltage regulation of EK external boiler temperature output --
2 GND
3 PWM PWM controller output for solar pump control output --
Terminal
Abbreviation
Terminal name - Description - Special INPUTSINPUTS Log. Sensor type, note
4 AF
outdoor temperature sensor (GND terminal 6 - together with WF sensor)
input NTC20
5 WF boiler water temperature sensor input NTC20 / PT1000
6 GND
7 SF domestic hot water temperature sensor (DHW.) input NTC20 / PT1000
8 GND
9 VF1 heating circuit temperature sensor 1 input NTC20 / PT1000
10 GND
11 VF2 heating circuit temperature sensor 2 input NTC20 / PT1000
12 GND
13 AGF flue gas sensor (flue gas duct) input PT 1000 / NTC20
14 GND
15 PF accumulation tank upper temperature sensor input NTC20 / PT1000
16 GND
17 VI1 optional VI1 input for sensor input NTC20 / PT1000
18 GND
19 VI2 optional VI2 input for sensor input NTC20 / PT1000
20 GND
21 VI3 optional VI3 input for sensor input NTC20 / PT1000
22 GND
23 VI4 optional VI4 input for sensor (ARU5) input NTC20
24 GND
25 VI5 optional VI5 input for sensor (ARU5) input NTC20
26 GND
Terminal
Abbreviation
Terminal name - Description - CommunicationCommunication Log. Sensor type, note
27 12V
ATMOS 485 communication line for ARU 10/30 room units --
Connected to the CU
28 A
29 B
30 GND
31 12V
ATMOS 485 communication line for ARU 10/30 room units --
Connected to the CU
32 A
33 B
34 GND
INFO - Always measure the flue gas temperature and solar panel temperature with a PT
1000 sensor
5. Connection

Operation manual - EN
www.atmos.eu EN - 19
ACD03/04
Terminal
Abbreviation
Terminal name - Description - Special OUTPUTSOUTPUTS Log. Sensor type, note
35 PE VA3 and VA4 output grounding output
36 N VA3 output neutral cable output 230 V / 50 Hz
37 VA3 LA VA3 output el. phase or one direction of MK3 rotation
38 VA4 LB VA4 output el. phase or second direction of MK3 rotation output 230 V / 50 Hz
39 N VA4 output neutral cable
40 MK1 LA el. phase of one direction of rotation of MK1 actuator
output 230 V / 50 Hz41 MKl LB el. phase of second direction of rotation of MK1 actuator
42 N MK1 actuator neutral cable
43 MK2 LA el. phase of one direction of rotation of MK2 actuator
output 230 V / 50 Hz44 MK2 LB el. phase of second direction of rotation of MK2 actuator
45 N MK2 actuator neutral cable
46 VA2 L VA2 output el. phase
output 230 V / 50 Hz47 N VA2 output neutral cable
48 PE VA2 output grounding
49 PT L el. phase for analogue room thermostat output 230 V / 50 Hz
50 N neutral cable for analogue room thermostat
Terminal
Abbreviation
Terminal name - Description - Special INPUTSINPUTS Log. Sensor type, note
51 DVI1
ON / OFF digital input (signal form analogue room thermostat)
input
52 DVI2
ON / OFF digital input (signal form analogue room thermostat)
input
Terminal
Abbreviation
Terminal name - Description - Special OUTPUTSOUTPUTS Log. Sensor type, note
53 MKP1 L MKP1 output el. phase
output 230 V / 50 Hz54 N MKP1 output neutral cable
55 PE MKP1 output grounding
56 MKP2 L MKP2 output el. phase
output 230 V / 50 Hz57 N MKP2 output neutral cable
58 PE MKP2 output grounding
59 DKP L DKP output el. phase (L-PUMP)
output 230 V / 50 Hz60 N DKP output neutral cable
61 PE DKP output grounding
62 SLP L SLP output el. phase
output 230 V / 50 Hz63 N SLP output neutral cable
64 PE SLP output grounding
Terminal
Abbreviation
Terminal name - Description - Special INPUTSINPUTS Log. Sensor type, note
65 IN L
contact power supply (el. phase) for L-FAN (L-FAN IN) 230 V / 50 Hz
input
Connected to the CU
66 L controller power supply (REG-L) 230 V / 50 Hz input
Connected to the CU
67 N controller neutral cable (REG-N) input
Connected to the CU
68 PE controller grounding (REG-PE)
Terminal
Abbreviation
Terminal name - Description - Special OUTPUTSOUTPUTS Log. Sensor type, note
69 VA1 VA1 output phase 230 V / 50 Hz output
Connected to the CU
70 FAN L L-FAN output phase (L-FAN OUT) 230 V / 50 Hz output
Connected to the CU
5. Connection
INFO - We recommend leading the sensor and communication cables separately from
230 V conductors and other power lines (at least 5 cm).

Operation manual - EN
www.atmos.eu
EN - 20
ACD03/04
6. INSTALLATION GUIDE (WIZARD)
(first start of the controller)
Before starting the controller for the first time, read chapter Hydraulics, so that the hydraulic
diagram can be set correctly according to your actual wiring in the boiler room.
INFO - All controller settings can be later adjusted as needed.
Installation Guide
Loading
and
starting mode
Language selection
(confirm with the green arrow at the top right)
Date
and
time setting
Option to upload saved settings (backup) from SD card
For new installation, select NO
When replacing the controller (to upload backup), select YES
(confirm with the green arrow in the upper right corner)
(use the red arrow in the upper left corner to
return to the previous setting)
6. Installation guide (WIZARD)
This manual suits for next models
1
Table of contents