Avanza aSL.1503 aSmart Lite User manual

AV-0017-MIW Rv000
Installation Manual
aSL.1503
aSmart Lite
1
aSmart Lite is a home management device
designed to satisfy the most common home
automation and control needs. According to its
integration philosophy, both its menu and
installation can be easily managed. aSmart Lite
offers an alphanumeric LCD Screen module 16x2,
where the information and the messages of the
system are displayed. aSmart Lite (aSL.1503) is
a model whose features are very appreciated in
the context of energy saving as for instance: the
heating/cooling management.
This document is intended to guide installer in
pre-installation tasks and a satisfactory installation
of the product.

AV-0017-MIW Rv000
Installation Manual aSmart Lite aSL.1503
2
RECOMMENDATIONS
GUARANTEE
This guarantee shall only be valid if it is correctly completed,
The SELLER STAMP and DATE OF SALE are essential.
Two-year guarantee, to be counted from the date of sale, against
all operational manufacturing or material defects.
The guarantee shall be considered voided in any of the following
circumstances taking place:
If the guarantee certificate is not duly completed or its
data are manipulated.
If the equipment has been used improperly and not in
accordance with the instructions for use.
If the equipment has been disassembled or manipulated
by persons other than authorized technical service.
If the fault was caused by knocks or falls, etc..
If the equipment has been connected to a voltage other
than that indicated in the installation manual.
The guarantee does not include repairs for faults occurring as
a result of causes not attributable to AVANZA ENGINEERING,
such as fires, explosions, floods, lightening or similar events.
In addition, the statutory rights of the guarantee holder are not
affected.
The suggestions below will help you to protect your warranty
coverage:
Please read all the operation instructions before using aSmart
Lite .
aSmart Lite must be installed indoors.
Keep this device away from moisture.
Use a damp cloth to clean the screen and the frame; do not
use any chemical, solvent or detergent.
Prevent direct solar radiation incidence, proximity of TVs,
lamps, fireplaces, heating pipes and in general any other
source of heat.
Avoid exposure to electromagnetic fields.
Keep the temperature sensor as far away from heat sources
as possible in a place where the temperature matches average
temperature of the house.
BOX CONTENT
1 aSmart Lite home management device
1 Temperature sensor for mechanism box
1 Terminal block, plug-in, 3-way
1 Terminal block, plug-in, 2- way
1 Terminal block, plug-in, 12-way
2 Beautifying lids
4 Fastening screws for fixing the flush-mounted box
1 Installation guide
1 User guide
MANUAL DE
INSTALACION
MANUAL DE
USUARIO

AV-0017-MIW Rv000
Installation Manual aSmart Lite aSL.1503
3
PREINSTALLATION
aSmart Lite pre-installation, envisages the flush mounted box in-
wall installation.
We recommend placing aSmart Lite by the exit door and at a
height of approximately 140 cm.
At this point aSmart Lite can be handled comfortably and it is
located at the ideal viewing angle.
It will be necessary to use corrugated tubes of 20 mm diameter
to communicate the flush mounted box with the home electrical
distribution panels, the communication box, the boiler or the
heating/cooling system of the house.
In the table below is shown the relation between tube diameter,
cables section and number of conductors.
In Figures 1 and 2 are schematically shown two ways of
communicating the boxes in the pre-installation, in order to make
it easier the later installation of cables and engines.
Figure 1 is the simplest, which is proposed for basic model. In
Figure 2 has been considered an additional wiring compartment
which will be really useful in the event that the installation provides
additional optional sensors. It has been considered a mechanism
box to lodge the temperature sensor of temperature management.
Conductor cross
sections (mm2)
Tubes external diameter (mm)
1,5
2,5
4
6
10
12
12
12
12
16
12
12
16
16
20
16
16
20
20
25
16
16
20
20
32
16
20
20
25
32
Boiler
(Fig. 1)
Communication
Box
Home Electrical
Distribution Panels
aSmart Lite flush
mounted box
(Fig. 2)
Boiler
aSmart Lite flush
mounted box
Communication
Box
Home Electrical
Distribution Panels
Temperature
sensor box
Wiring
Compartment
Temperature
sensor box
140 mm aprox.
140 cm
140 cm aprox.

AV-0017-MIW Rv000
Installation Manual aSmart Lite aSL.1503
4
INSTALLATION DIAGRAM
F
N
Thermostat
Connections
F
N
230 Vac
S2
S3
S1
USE AFTER PROTECTIONS
BOILER
+
15 V dc INPUTS
L1
L2
Tfno
NC
E1
E2
E3
E4
-
NC
NC
NC
J1
J2
J3
J4
EXTERNAL
TEMPERATURE
SENSOR
NTU
TELEPHONE LINE

AV-0017-MIW Rv000
Installation Manual aSmart Lite aSL.1503
5
aSmart Lite WIRING
NTU
aSmart Lite
For connecting 230V electrical devices we
recommend using wires of 1.5 mm cross-
section diameter minimum, and using
standard color-coded wires according to the
type of connection which means black, grey
or brown for the phase and bleu for the
neutral.
For sensors we recommend using multi-
wired cable of 4 wires of 0.25 mm2.
Current-limiting circuit-breaker
Differential
Magnetothermic
Home electrical
distribution panels
Electric connection
Phase Neutral
Power Supply
230 Vac
Communication Box
Installation of Telephone
internal inlets
External Telephone line
aSmart Telephone line
aSmart Lite
Flux mounted box
To the boiler
thermostat
External temperature
sensor
E2

AV-0017-MIW Rv000
Installation Manual aSmart Lite aSL.1503
6
INSTALLATION SEQUENCE
We proceed to introduce the cables up to the
flux mounted box. Then we mark cables and
connect them into the plug-in terminals
provided as is shown in figure below. Within
this step we could check voltage and
continuity, remaining ready waiting for the
wall to be rounded off.
Step 2
Telephone Line
Boiler Connection
Power Supply
230 Vac
External
temperature
sensor
Temperature sensor
We will place the flush-mounted box at a
height of approximately 140 cm from the
ground.
The dimensions of the box are:
220 mm x 150 mm x 52mm
Step 1

AV-0017-MIW Rv000
Installation Manual aSmart Lite aSL.1503
7
INSTALLATION SEQUENCE
Once the device has been screwed, we place the
beautifying lids on aSmart Lite and we push down until
hearing a "click" sound, as indicated in the pictures on the
right.
Step 4
click
click
click
click
We proceed to connect the terminals to aSmart Lite home
management device as indicated in Figure of installation.
Then we arrange the wires, and after that we place the
device within the flush mounting box and screw them.
Step 3

AV-0017-MIW Rv000
Installation Manual aSmart Lite aSL.1503
8
INSTALLATION OF ADITIONAL SENSORS (Optional)
Optional Fire Sensors
+E3
GND
aSmart Lite is fitted with a motion sensor and a fire sensor.
Many times the intrusion and fire alarms only require of
these sensors to work properly.
aSmart Lite makes it possible to install additional motion
and fire sensors to protect other zones if necessary.
Installation is shown in figures 1 and 2.
Caja de
registro
Optional Motion
Sensors
+E1
GND
In figures below are shown some installation examples
when there are motion and fire additional sensors.
aSmart Lite source of electricity makes it possible to supply
these external sensors up to a maximum of 6.
On this purporse it will be necessary to know the power
consumption of the sensors to be installed to avoid
exceeding the maximum supply current provided by aSmart
Lite source of electricity (150 mA).
In case of doubt we recommend supplying the sensors
with an external source of electricity.
+E3
GND
Motion sensor
12V Supply
Take the jumper J1 of
input E1 out.
(Fig. 1)
+
15 V dc ENTRADAS
L1
L2
Tfno
NC
E1
E2
E3
E4
-
NC
NC
NC
J1
J2
J3
J4
(Fig. 2)
Take the jumper J3 of
input E3 out.
Fire sensor
12V Supply
+
15 V dc ENTRADAS
L1
L2
Tfno
NC
E1
E2
E3
E4
-
NC
NC
NC
J1
J2
J3
J4

AV-0017-MIW Rv000
Installation Manual aSmart Lite aSL.1503
9
TECHNICAL DATA
Home Temperature from -7ºC to 50ºC
Width - height - depth (mm)
Installed
F ( Phase )
N ( Neutral )
(Ground)
E1 (Input 1) *Intrusion Sensors in closed loop with GND
E2 (Input 2)
E3 (Input 3)
External temperature sensor
E4 (Input 4)
(+) Positive 15 Vcc Positive with charge (Max. 150 mA)
S1 (Outlet 1) Not used
S2 (Outlet 2) Heating/Cooling control. Maximum 16A to 230 ca
S3 (Outlet 3)
Power source outlet
GND
NA Potential-free contacts
relays
Inputs
Voltage of power supply
230 Vac 50 Hz
(127 Vac 60 hz available upon request)
Consumption:<40mA-9w
TERMINALS DESCRIPTION
FEATURES
POWER SUPPLY INPUT
VOLTAGE OF THE POWER SUPPLY OUTLET TO EXTERNAL SENSORS
OUTLETS
EXTERNAL SENSORS INPUTS
DIMENSIONS
OPERATION TEMPERATURE LEVEL
Not used
*Fire Sensors in closed loop with GND
Not Implemented.
226mm x 152 mm x 44 mm
226mm x 152 mm x 8mm
If you are not going to install these optional motion/fire sensors, it is recommended that you make sure that inputs have
been disabled using jumpers J1 and J3 respectively.
Pamplona - SPAIN
Tel. +34 948 25 84 24
www.avanzaengineering.com
Other manuals for aSL.1503 aSmart Lite
1
This manual suits for next models
1
Table of contents
Popular Control System manuals by other brands

Lutron Electronics
Lutron Electronics GRAFIK Eye QSG-3PCE Installation and operation guide

ATEN
ATEN VK2100 user manual

CYBELEC
CYBELEC DNC 60 PS user guide

Intermatic
Intermatic GM40AVE Installation and operating instructions

Jandy
Jandy AquaLink RS6 installation manual

Swagelok
Swagelok Changeover SCO user manual