2
Warranty Information
One YEAR WARRANTY
All claims for parts or labor must be made directly through Atosa. All claims must include the model number of the
unit, serial number, proof of purchase, date of
installation. and all pertinent information supporting the alleged defect. In case of a compressor replacement under
warranty. either the compressor or compressor tag must be returned to Atosa along with above listed information.
Failure to comply with warranty policies will result in voiding claims.
One Year Parts & Labor Warranty
Atosa warrants all new refrigerated components such as the cabinet and all parts, to be free from defects in materials
or workmanship. Atosa's obligation under this
warranty is limited to a period of one (1) years from the date of original installation or 15 months after shipment date
from Atosa or, whichever occurs first. All parts covered under this warranty that are defective within one(1) years of
original installation or fifteen (15) months after shipment date from manufacturer, whichever occurs first, are
limited to repair or replacement (including labor charges, of defective parts or assemblies) The labor warranty shall
include standard straight time labor charges only and reasonable travel time, as determined by Atosa.
Additional Four-Year Compressor Warranty
In addition to the one(1) Year warranty stated above. Atosa warrants its sealed compressor to be free from defects in
both material and workmanship under normal and proper use and maintenance service for a period of four (4)
additional years from the date of original installation, but not to exceed five (5) years. Compressors that have been
determined to be defective from Atosa within this extended period will be either repaired or replaced with a
compressor or compressor parts of similar design and capacity according to Atosa'sdiscretion . The four (4) year
extended compressor warranty applies only to sealed parts of the compressor and does not apply to any other parts
or components. This includes. the cabinet, paint finish, temperature control, refrigerant, metering device, motor
starting equipment, fan assembly and other electrical components, etc.
Compressor Warranty
The five-year compressor warranty detailed above will be void if the following procedure is not carefully adhered to:
1.This system contains refrigerant and lubricant. The lubricant has rapid moisture absorbing qualities.
2.Drier replacement is very important and must be changed when a system is opened for servicing.
3.Micron level vacuums must be achieved to insure low moisture levels in the System.
4.Compressor must be obtained through Atosa unless otherwise specified in writing through Atosa's warranty
department.
What is Not Covered by This Warranty
Atosa's sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional
limitations below. This warranty neither assumes nor authorizes any person to assume obligations other than those
expressly covered by this warranty.
NO CONSEQUENTIAL DAMAGES: ATOSA IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT LOSS; OR SPECIAL. IN
DIRECT, OR CONSEQUENTIAL DAMAGES,INCLUDING WITHOUT LIMITATION, LOSSES. OR DAMAGES ARISING FROM
FOOD OR PRODUCT SPOILAGE,REGARDLESS OF WHETHER OR NOT THEY RESULT FROM REFRIGERATION FAILURE.
WARRANTY IS NOT TRANSFERABLE:This warranty is not assignable and applies only in favor ofthe original purchase
/user to whom delivered. ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THEWARRANNTIES HEREIN
AND SHALL VOID ALL WARRANTIES. EXPRESS OR IMPLIED. INCLUDING ANY WARRANTY OF MERCHANTABILITY OR
LABOR COVERAGE FOR COMPONENT FAILURE OR OTHERTHE WARRANTY PACKET PROVIDED
WITH THE UNIT.

3
ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE, FOOD, OR
ACTS OF GOD:
Atosa is not responsible for the repair or replacement of any parts that are determined to have been subjected after
the date of manufacture to alteration, neglect, abuse, misuse, accident, damage during transit or installation, fire,
flood, or act of God.
IMPROPER ELECTRICAL CONNECTIONS:Atosa IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR
DAMAGED COMPONENTS RESULTING FROM ELECTRICAL POWER FAILURE, THE USE OF EXTENSION CORDS, LOW
VOLTAGE, OR VOLTAGE DROPS TO THE UNIT.
THE ONE(1) YEAR PARTS & LABOR WARRANTYAND THE ADDITIONAI FOUR (4) YEAR COMPRESSOR WARRANTY ARE AS
DESCRIBED ABOVE. THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, INCLUDING
IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULARPURPOSE. THERE ARE NO WARRANTIES
WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.
Outside U.S. and Canada:This warranty does not apply to areas outside the continent of the United States. Atosa is
not responsible for any warranty claims made on products sold or used in such areas.
*In some cases. a 25 % restocking fee may be charged to a buyer for returned items.*
Atosa may at any time modify our equipment in order to provide and insure a superior product. Change
is sometimes necessary to keep up with today’s high standards in our industry. Atosa reserves the final
interpretation of all public material.
Important Child Safety
Destroy or recycle the carton, plastic bags, and any exterior wrapping material
immediately after the unit is unpacked. Children should never use these items
to play.

4
Product Information
--Structural diagram
CTD-3
CTD-3S
CTD-5

5
--Technical Specification
Model
CTD-3
CTD-3S
CTD-5
Rated Electric
115v, 60Hz, 1.5A
115v, 60Hz, 1.5A
115v, 60Hz, 1.7A
Refrigrant(Ounces)
R600a / 1.06
R600a / 1.16
R600a / 1.58
Design
Pressure(High/Low)
280 psig / 90 psig
280 psig / 90 psig
280 psig / 90 psig
Net weight(KG)
24
29
40
--Safe Cautions
1. This unit uses AC110V/60Hz power, there should be a 500va stabilizer if the voltage fluctuation
exceeds AC99V-132V
2. The user should hold the plug when the power is on /off, dragging or pulling the power cord is
prohibited.
3. Do not remove the power cord or plug
4. Must use dependent socket and reliable ground wire. Ground wire must not connect with the null
line of the gas pipe, warm gas pipe, water pipe and must be single power
5. Never splash water on the unit directly.
6. Keep away from explosive, hazardous goods such as ether, gas, alcohol, bonding agents, gunpowder
etc.
7. Keep away from spray of inflammables such as paints, coating materials etc.
8. After the unit is switched off, it should not be restarted within 5 minutes.
9. Do not leave the power cord under any heavy objects including the unit itself.
10. Do not drill holes or install other objects on the casing.
11. This cooler is not suitable for storage pharmaceutical products.
--Portage and storage
1. Keep the unit vertical when carrying the unit, the angle to the horizontal line should not be over
50°,otherwise it will damage the compressor and affect normal operation of the unit.
2.The unit should be place on a solid and firm ground, take away the bottom pack to lower the shock
and noise.
3.Leave at least 20 cm of distance between the back of the unit and the wall for ventilation and leave a
space with an open angle of 160°for the door.
4.Keep the unit away from heat sources and avoiding direct sunlight.
5. Never place the unit on a location where water can reach or with high moisture. Splashed water and
dirt should be wiped off in time by using a soft cloth.
6. Do not place the unit in the environment cold enough to be iced.
--Preparation
1. Remove the carton and packing foam (including the bottom foam)before using.
2. Clean the unit before using.
3. Adjust the foot to make the unit steady according to the ground condition to lower the shock and
noise.

6
4. After moving the unit, place the unit for 30 minutes before switching it on.
Running: close the door and connect the power, turn on the lamp switch on the control panel, the
lamp is on. Half an hour later, the temperature inside the case lower apparently, it indicates the
unit on be normally used
5. After connecting the power, the unit should be kept empty for one hour.
--Setting and adjustment of temperature
1. Adjust the storage temperature through the temperature controller located in the internal of the
case(see the picture),adjust the temperature according to the ambient temperature and the
foodstuff.
2. See the following picture about the knob scale. The temperature adjustable capacity is from
“1”-“5”,adjust the storage temperature by turning the temperature controller clockwise. The higher
of the number shows the lower of the storage temperature. The knob can turn freely but can’t turn
clockwise from “5”-“1”. Factory setting position is on “3”
3. Check if the scale is on an appropriate position before using, summer, the ambient temperature
is high, anti-clockwise turn the knob to “2”, while in winter, the ambient temperature is
low, clockwise turn the knob to “4”.
4. Position “0” represent stop running.
--Storage of articles
1) Do not put large amount of articles into the unit at one time, you should leave some space around
the foodstuff to let cold air inside the cabinet counter to flow. Keep bottled articles away from the
walls of interior cabinet so as not to freeze it until broken.
2) Do not put warm food into the unit directly until they are cooled under normal temperature, it will
facilitate to lower its energy consumption and prolong service life of the compressor.
--Maintenance
Disconnect the power supply before maintenance for the machine!
1) Keep the door gasket clean, remove it from the door and wash it. Dry and seal it as before. Putting
some talcum powder on the magnetic surface would prolong its service life.
2) Bulb replacement:remove the lamp shade, take out the bulb, replace with a new bulb, then
mount it again.
3) If there is heavy frost on the evaporator after long usage, take out the stuff inside the case,
disconnect the power, the frost will melt automatically, clean up the water and connect the power
again.
4) Use a soft cloth and dip some water or soap (Non-caustic, neutral detergent is also available) to
clean the unit. Dry the unit after cleaning to avoid rust.

7
5) Do not use organic liquid, boiled water, washing powder or acid stuff to clean the unit. Rinsing the
case by water is not allowed, don't use hard brush, steel brush to clean the case.
6) If the unit will not be used for a long time, disconnect the power, clean it by following the above
steps, wipe off the water inside the case with a soft cloth.
--Caution
1) The unit is not suitable for storage of blood, pharmaceutical products and biological products
2) Do not place heavy articles on the top of the unit.
3) In case of trouble, please ask professional person for service, do not dismantle the unit without prior
authority to avoid hazard
--Normal Phenomena
1) Sometime hear light sound of water flowing in the unit, this is the sound of refrigerant flowing inside
the pipe.
2) the top ,and the two sides of the casing will be warm, even too hot.
3) In a humidity place, there is dew on the casing or the door, it can dry by dry cloth.
--Troubleshooting guide
Problems
Possible cause
Ways to solve problems
The units does not work
Bad connection of plug
re-connect the plug to power
supply
Abnormal operation of
the compressor or has
buzz sound
The power voltage is out
of the rated range.
Disconnect the power supply
immediately and reconnect with
it after normal voltage.It is
necessary to have a voltage
stabilizer in case of poor power
supply.
Compressor operatestoo
long time and no frost on
the surface of inner
cabinet
Refrigeration system is at
fault(leakage or blocked)
Send the unit to service
department for repair
There is frost or ice on the
evaporator of the inner
cabinet and too low
internal temperature,the
compressor operates
never stop
Thermostat does not work
Ask service department for repair

8
The internal temperature
is too high, and the
compressor operation
doesn’t stop
Bad heat dissipation and
ventilation of casing, the
ambient temperature is
too high
Improve ventilation and improve
the ambient temperature
Too much warm food was
put in at one time
Take out some food
Door open frequently and
longtime door opening
Decrease number and times of
door opening
Too high noise
The unit is not level
Adjust the adjustable foots
The fastener of the unit is
loose
Fasten the loose fastener
Pipes are touching the
compressor
Carefully separate the touching
pipes
Lamp is not on
The lamp is burned out
Replace the lamp

9
Technical Service Information
--Exploded view of CTD-3
--Part list of CTD-3
No in explode view
Part number
Description
Qty.
1
CTD001
Thermostat knob
1
2
CTD002
Thermostat (WP1)
1
3
CTD003
ON/OFF button
1
4
CTD004
Temperature control box
1
5
CTD005
Filter(∅16 ∗30)
1
6
CTD006
Constant current power supply
1 AC85v-265v-15D
7
CTD007
Water receiving plate
1
8
CTD008
Compressor(UKN43YA)
1
9
CTD009
Power line (JT-3)
1
10
CTD010
Base foot
4
11
CTD011
Hinge cover
1
12
CTD012
Hinge upper
1
13
CTD013
Led lamp
1
14
CTD014
Evaporimeter
1
15
CTD015
Door seal
1
16
CTD016
Door
1
17
CTD017
Hinge down
1
18
CTD018
Lock
1
19
CTD019
Shelf bottom
1
20
CTD020
Shelf top
2

10
--Exploded view of CTD-3S
--Part list of CTD-3S
No in explode view
Part number
Description
Qty.
1
CTD009
Power line (JT-3)
1
2
CTD021
Thermostat knob
1
3
CTD003
ON/OFF button
2
4
CTD022
Compressor(UKN60YA)
1
5
CTD005
Filter(∅16 ∗30)
1
6
CTD023
Led lamp
1
7
CTD006
Constant current power supply
1 AC85v-265v-15D
8
CTD010
Base foot
4
9
CTD024
Condenser
1
10
CTD002
Thermostat (WP1)
1
11
CTD025
Lamp plate
1
12
CTD026
Lamp
1
13
CTD027
Door seal
1
14
CTD028
Hinge upper
1
15
CTD029
Door
1
16
CTD018
Lock
1
17
CTD030
Hinge down
1
18
CTD031
Shelf
3
19
CTD032
Water receiving plate
1
20
CTD033
Guide
2

11
--Exploded view of CTD-5
--Part list of CTD-5
No in explode view
Part number
Description
Qty.
1
CTD034
Condenser
1
2
CTD001
Thermostat knob
1
3
CTD005
Filter(∅16 ∗30)
1
4
CTD006
Constant current power supply
1 AC85v-265v-15D
5
CTD009
Power line (JT-3)
1
6
CTD035
Water receiving plate
1
7
CTD022
Compressor(UKN60YA)
1
8
CTD010
Base foot
4
9
CTD002
Thermostat (WP1)
1
10
CTD003
ON/OFF button
1
11
CTD036
Led lamp
1
12
CTD037
Evaporimeter
1
13
CTD038
Fan
1
14
CTD039
Fan cover
1
15
CTD011
Hinge cover
1
16
CTD041
Hinge upper
1
17
CTD042
Door
1
18
CTD043
Hinge down
1
19
CTD018
Lock
1
20
CTD044
Door seal
1
21
CTD045
Shelf bottom
1
22
CTD046
Shelf top
3

12
--Electric Connection Diagram
CTD-3 Diagram
CTD-3S Diagram
CTD-5 Diagram