Autoplugin Key-V3 User manual

Autoplugin Key-V3
Version 9.6
User Manual
Rev. B

2
Table of Contents
Description …………………………….………………………………………
3
Module Possibilities ………………………………………..………………..
3
Package Content ………………………………………………………………..
3
Connection ……………………………………………………………………..
3
Basic Functions ………………………………………………………………...
4
Additional Functions ………….………………………………………………..
4
Troubleshooting …………………………………………………………….….
7
Glossary
CAN - Control Area Network (digital network for data transfer in vehicles)
CIP - Combined Instrument Panel
PCC – Personal Car Communicator

3
Description
The Autoplugin Key-V3 is an electronic module designed to add a remote control
function to the fuel-fired heater (parking heater, fuel operated heater, pre-heater),
factory installed in Volvo С30 (2006-2012), S40 (2004-2012), V50 (2004-2012)or
C70 (2006-2013). The device is plugged into the diagnostic socket placed on the
dashboard, and controls the heater via CAN-bus.
Module Possibilities
·Immediate start of the heater with Volvo car’s key. Both a key with 5
buttons and a PCC key with 6 buttons can be used for the heater control
·Immediate stop of the heater with Volvo car’s key
·Indication of the heater autonomous operation with direction indicators
flashing in rearview mirrors.
·Additional main battery protection from discharging by inspecting of
voltage level and time of heater autonomous operation
Package Content
1. Autoplugin Key-V3 cartridge
2. User Manual brochure
Connection
The module needs that 2 timers and direct start / stop function for the heater
control are present in CIP. Therefore it may be necessary to load the special
software to the CIP at first by the means of Volvo dealer’s equipment.
Autoplugin Key does not need professional installation. Find the diagnostic socket
at the left lower point of the dashboard. The socket is placed near to the handle for
bonnet opening. Take the module to your hand and gently push it into the socket.
LED starts flashing for approximately 10 seconds, waiting for information from
CAN-bus. Wait until the LED stops flashing before operation. Turn the ignition on
if the LED continues flashing after 10 seconds expired.

4
Basic Functions
1. A special combination of buttons presses is used to start the heater from a
remote control key. Firstly press “Lamp” button on the key to switch on car
lighting. Then press “Lock” button twice within 30 seconds, while lighting
is on. Every “Lock” button pressing is confirmed with direction indicators
flashing.
2. To stop the heater with a remote control key, switch on and then switch off
car lighting twice. Intervals between “Lamp” button presses should not
exceed 20 seconds.
3. It is possible remotely disable heater timers, programmed in the CIP. Use
remote control key to send stop command when the heater is idle. Starting
the heater any way or turning ignition to “on” position enables CIP timers
again.
Additional Functions
By default the module adjusted to perform only basic functions, such as start
and stop of the heater by using remote control key. To switch on additional
functions such as flashing with direction indicators in rearview mirrors, etc. enter
the module into Setup mode and activate corresponding setup item (see settings
table 1).
The buttons of the left-hand stalk switch and the brakes pedal are used to
enter Setup mode and to change the settings. It is necessary to stop the engine and
the heater before. Switch the ignition on (turn the key to the position II), then press
and hold the brakes pedal. Rotate the thumbwheel some steps to select blank
display in the CIP. Then press and hold for at least 5 seconds “Read” button (“OK”
button in some cars), while module’s LED flashes once a second. Both direction
indicators in the CIP confirm entering setup mode with 2 flashes. Release the
brakes pedal and “Read/OK” button finally.
Each setup item in the settings table is a 3-digit code. To enter a digit of a
code, shortly press “RESET” button so much times, as corresponds to a digit. The
LED and the direction indicators symbols in the CIP confirm each button press: the
LED briefly goes off, the left direction indicator flashes one time when the first or
the third digit of code is entered, the right direction indicator - when the second
digit of code is entered. To complete a digit entering, press and release “Read/OK”
button. The CIP confirms it with one flash of both direction indicators
simultaneously. When all three digits are entered, the module checks the code for
validity and confirms it with direction indicators flashing. Both direction indicators
flash twice simultaneously in case of valid code and flash twice alternately in case
of invalid code.

5
If entered digit is not correct, press and release “Read/OK” button until the module
indicates an error. Enter the code once more in that case. Several codes can be
entered without exit of setup mode.
Turn the ignition off to exit from the Setup mode. New settings are saved in the
non-volatile memory of the module and stored there regardless of whether the
module is connected or not. Note: start the engine inside the Setup mode if you
want to exit without saving of new settings.
To reset the module to factory settings, enter the code 8.1.1. Both direction
indicators in the CIP should flash three times, confirming command execution.
Then the module exits Setup mode and restarts.
Settings table (1)
Settings
Group
Settings
Item
Possible Values
1.
Heater’s
operation
time
1.1. Limitation of
heater total
operational time in
pre-heat mode
1.1.1 *Not adjusted
1.1.2 40 minutes
1.1.3 50 minutes
1.1.4 60 minutes
1.1.5 70 minutes
1.1.6 80 minutes
1.1.7 90 minutes
1.1.8 100 minutes
1.1.9 120 minutes
1.2. Limitation of
heater 1-cycle
operational time in
pre-heat mode
1.2.1 10 minutes
1.2.2 15 minutes
1.2.3 20 minutes
1.2.4 25 minutes
1.2.5 30 minutes
1.2.6 40 minutes
1.2.7 50 minutes
1.2.8 60 minutes
1.2.9 *Not adjusted
2.
Heater
control with
remote
control key
2.1. “Lock” and
“Lamp” buttons
functions for heater
control
2.1.1 *”Lock” button for the heater start,
“Lamp” button for the heater stop
2.1.2 “Lamp” button for the heater start,
“Lock” button for the heater stop
2.2. Number of
sequential “Lamp”
button presses for
heater control
2.2.1 Two presses
2.2.2 *Four presses
2.2.3 Six presses
2.2.4 Combination is disabled
2.3. Number of
sequential “Lock”
button presses for
heater control
(when perimeter
lighting is on)
2.3.1 One press
2.3.2 *Two presses
2.3.3 Three presses
2.3.4 Combination is disabled

6
3.
Battery
Monitoring
3.1.
Minimal battery
voltage that lets the
module start the
heater in pre-heat
mode
3.1.1 * Not adjusted
3.1.2 11.7V
3.1.3 11.8V
3.1.4 11.9V
3.1.5 12.0V
3.1.6 12.1V
3.1.7 12.2V
3.1.8 12.3V
3.1.9 12.4V
3.2.
Minimal battery
voltage that lets the
module keep
operating the heater
in pre-heat mode
1
3.2.1 * Not adjusted
3.2.2 11.4V
3.2.3 11.5V
3.2.4 11.6V
3.2.5 11.7V
3.2.6 11.8V
3.2.7 11.9V
3.2.8 12.0V
6.
Indication
with
direction
indicators in
rearview
mirrors
6.1. Indication of
heater startup
6.1.1 *Off
6.1.2 Five flashes
6.2. Indication of
command reception
from a remote
control
6.2.1 *Off
6.2.2 Three flashes
6.3. Indication of
heater operation,
when starting
source is a remote
control
6.3.1 *Off
6.3.2 On
6.4. Indication of
heater operation,
when starting
source is the CIP
(direct start)
6.4.1 *Off
6.4.2 On
6.5. Indication of
heater operation,
when starting
source is other than
specified in 6.3,6.4
6.5.1 *Off
6.5.2 On
6.7. Flashing
frequency for 6.3-
6.4 Setup items
6.7.1 One flash within 3 sec
6.7.2 One flash within 5 sec
6.7.3 *One flash within 10 sec
6.7.4 One flash within 15 sec

7
8.
Service
menu
8.1. Default Settings
8.1.1 Apply factory settings
* Factory setting
Recommended settings marked in Italics
1
–The module turns off the heater if battery voltage lowers to the adjusted limit
Troubleshooting
If a run-time error occurs during heater operation, Autoplugin Key informs about
the error code with embedded LED flashing. The number of flashes corresponds to
the error code. See table 2 for the errors description and possible solutions.
Table 2
Error
Code
Error
Description
Possible Reasons of
Error Appearance
Solutions
2
No answer
from the
heater
followed the
start
command
Outer temperature
displayed in CIP is
higher than +14 Celsius
degrees
The heater operates only at
temperatures below +15°C. It
is heater manufacturer
restriction
Fuel level in the fuel
tank is close to empty
(“Fuel Low” warning
indicator is illuminated
in the CIP)
Refuel the car
The heater is blocked
after several
unsuccessful starts
Try to start the heater in the
CIP menu. If it doesn’t start
up, make diagnostics of the
heater.
3
Battery low
The module has
determined that the
battery voltage is below
the specified by settings
items 3.1 or 3.2
Charge car’s battery with
special charger (or start engine
to charge) or cancel 3.1/3.2
module’s settings
4
Time limits
exceeded
Time limit for
autonomous operation of
the heater is achieved
Run the engine or cancel 1.1
module’s settings
5
Unsuccessful
start
The heater was switched
off spontaneously at
starting
Make diagnostics of the heater
if the error appears again
6
Operation
cycle too
short
The heater was switched
off spontaneously
Make diagnostics of the heater
if the error appears again

8
8
CAN-bus
error
There is a problem with
connection of the
module to CAN-bus
Check for the module
connection
9
Settings error
Settings have been
stored in module’s
memory incorrectly
Reset the settings (8.1.1),
readjust the module
11
Heater no
connection
The heater is unplugged
or out of order
Make diagnostics of the heater
The device is powered from the diagnostic socket. Therefore if there is no any
indication on the module first of all check the car’s fuse for the diagnostic
socket.
© Autoplugin ES
Table of contents
Other Autoplugin Control Unit manuals