6
Kit .
The standard kit contains:
-control panel;
-fuel pump;
-fuel tank, fuel intake, tee pipe;
-wire harnesses;
-air intake;
-exhaust pipe;
-fasteners;
-muffler.
Optional (not in scope of supply): a cabin sensor and a GSM modem.
Responsibility
Failure to follow these instructions and the requirements
contained therein results in the exclusion of any liability on the part
of the manufacturer. The same applies to the repair specialist who
does not have the necessary qualifications, or uses non-original parts
without obtaining a permission of the manufacturer.
If you have any problems, we strongly recommend that you contact authorized service
centers, addresses and telephone numbers of which you can find out from the company, the
seller or on the website www.autoterm-europe.com
Automatic Control Features .
1) if for some reason the heater did not start, the start-up process will be automatically
repeated. After two failed attempts the heater will be switched off;
2) if during the heater's operation burning is interrupted, the heater automatically re-starts.
Restarts after consecutive flameouts are performed up to three times;
3) in case of overheating of the heater coil (for example, due to blocked intake or output
of the heating unit), the heater is automatically switched off;
4) if the maximum temperature of the heated air is exceeded (for example, due to closed
outlet of the heating unit), the heater is automatically switched off;
5) if voltage drops below 20V (10V) or increases to more than 30V (16V), the heater
automatically switches off. The numbers in parentheses are for the heaters with the
nominal voltage of 12V;
6) if the heater switches off due to an emergency situation, a malfunction code appears on
the control panel. The malfunction code and the LED indicating the operation mode
will be blinking.
7) in case one of the temperature sensors is faulty, the heater will not launch and a
malfunction code will appear on the control panel.