AV-GAD EasyLoader 4000 Series Technical document

EasyLoader
AV-4000 GSM
AV-4000 DVR
(for LED keypads)
Integrated Alarm Control panel &
Communicator Series 4000
Appendix for GSM Alarm Panels
Version 1.06
Edition II
This product is subject to continuous
enhancements and therefore specifications may
be changed or altered without prior notice
Item: 4785E_GSM (A4BKE)
Rev01: 03-Nov-2018

2
AV-4000 GSM Appendix
1. Introduction
Use this appendix with the AV-4044GSM, 4008SM, 4009GSM, 4016GSM
alarm panels, for installation manual refer to the Series 4000 LED express or
full manual. This appendix covers also the AV-4044, 4008DVR. All models are
supporting alarm sensors and sirens.
The series 4000 GSM and AV-4044DVR, AV-4008DVR GSM are compatible
with Av-Gad LED keypads models AV-701 and AV-702.
The AV-4044, 4008 GSM are supplied with the Gismo board that is plugged
into the serial RS-232 plug and connected to the integrated GSM modem.
The GSM panels are capable to send SMS via GSM and also to dial via GSM
(dial but without audio) and PSTN. Report to central station via GSM is not
available.
In GSM mode the remote DTMF feature is not active. The SMS texts are not
programmable (to be later).
In some regions the PSTN network supports SMS messaging, consider and
check if available with your PSTN provider.
Main features:
Transmits SMS (short text message) via the GSM network
Dials to regular numbers via GSM (after dial the unit disconnects, no
sound or alarm tune is generated, show the number dialed from to
receiver)
Dials to PSTN numbers with alarm sound when the phone picked up
Reports to central station via PSTN line (not via GSM)
Do not supports remote DTMF commands
Do not support voice module like SVM-40 if dial via GSM
Compatible with 2nd, 3rd (2G and 3G) generation SIM card
In Australia works and tested with vodafone SIM card
Integrates high end four bands GSM modem (Gismo M95)
Fully integrated with the alarm panel in ABS box
Periodical test signal in few modes
Send SMS with zone and events description (low battery, AC fail, etc)
Be aware of static electricity, don't touch the components directly

3
2. Hardware
The AV-4044, 4008, 4009, 4016 GSM suffix are based on the AV-4044, 4008,
4009 & 4016 LED panels and supplied with the additional hardware to provide
full GSM alarm panel.
To identify the GSM; The Gismo PCB board (refer to fig. 1) with antenna plug
located at the let-upper side in the main control panel case.
Pack includes GSM RF antenna. Before power up always connect the antenna
to prevent damage to the GSM module. Verify the antenna cable is not coiled.
Process wiring with power down; don't insert the SIM card with power on.
The Gismo has two indication LEDs, explained later.
Figure 1: Gismo 95 GSM module description
Notice
Most simple is to program the panel from the keypad, simple and fast.
In case EasyLoad programming applied for alarm with GisMo interfaced
proceed as following:
1. When programming with PC unplug the data cable from the alarm panel,
notice that some GSM features are not included in the PC program.
2. As programming done plug the data cable from the GisMo to the alarm panel.

4
GisMo wired to Alarm panel diagram
SERIAL
SVM IN
(AV-232)
+SIR-SIR
AUSTEL
+
E
B
E
B
C
C
E
+
+
+
+
PHONES
TEL-LINE SVM IN
RX
-V
+V
TX
E
B
C
B
E
B
E
+
E
B
C
+
+
PC95/5295
+
FA2
C6
VA10
U3
Q17
R30
R31
JP2
C22
R10
R25
R7
Q1
C4
C3
C2
C8
R2
R3
JP5JP4
R78
C16
C39
R79
R9
FA1
FA3
R32
+B
-B
Q18
JP3 R81
R83
R86
AC-16-AC
R8
JP6
KEY/Z9
B1
Fuse
Fuse
Fuse
PC
Here
Max.
1.10 A
Version
Label
Red wire
To +12V
Black &
Yellow
To -12V
Power cable
Data cable to JP1
At download process unplug data
cable
Yellow
wire
Yellow
wire
Antenna
Here
Insert gently
GisMo M95
Board
AV-4008
Board (only LED Ver.)
LEDs
GisMo board is
Sensitive to anti
static. Prevent
touching
Figure 2: Gismo 95 GSM module wired to alarm panel

5
3. Programming GSM and Dial features
To setup the panel wire the keypad model AV-701 or AV-702 (refer your panel
main manual).
Insert the SIM card and connect the GSM antenna
Power up with AC (not with battery at first power up)
Hold down key 8, enter 1 9 9 4 (programming code), P is displayed indicating
you are in PROGRAM mode. In programming mode enter 200, than the
required function as detailed below.
Series 4000 panels are capable to send SMS via GSM or PSTN, also can dial
via GSM or PSTN, the modes are programmable.
Programming the SMS mode dial modes:
Command Description Keypad display
Press 200 than 10 To display SMS sending way:
Via PSTN or via GSM network
Line = PSTN
Cell= GSM
Press 200 than 11 Panel send SMS via PSTN LINE
Press 200 than 12 Panel send SMS via GSM CELL
Press 200 than 50 To display the dial mode LINE or CELL
Press 200 than 51 Set panel to dial via PSTN LINE
Press 200 than 52 Set panel to dial via GSM (not ready yet) CELL
Programming the SMS language for the texts:
Command Description Keypad display
Press 200 than 20 To display SMS language HE or EN **
Press 200 than 21 Set SMS language to English (default) EN
Press 200 than 22 Set SMS language to Hebrew HE
HE= Hebrew, EN = English
** SMS texts are restored to defaults when changing SMS language
Three parameters affecting the SMS texts content for zones events
Address 138 - Using panel's fixed texts describing the event (Default 01 - yes)
Address 139 - Adding the zone number to SMS (Default 01 - yes)
Address 140 - Adding the text description of the zone via PC (Default 00 - no)
If all parameters are set to 0, the panel resets the defaults.

6
Programming the Dialing and SMS phone numbers:
- To enable sending SMS program address 003, enter 01 to enable
- In GSM mode address 008 is not in use
- Supports six Dial telephone numbers, each 16 digits, address 013 to 018
- Supports four SMS telephone numbers, each 16 digits. Enter the phone
numbers for SMS sending at address 009 to 012
- In phone numbers for GSM SMS/DIAL use digits 0-9 (none others)
4. AV-4044, 4008DVR GSM texts
Zone 1: Burglary at zone 1
Zone 2: Burglary at zone 2
Zone 3: Burglary at zone 3
Zone 4: Burglary at zone 4
Zone 5: Burglary at zone 5
Zone 6: Burglary at zone 6
Zone 7: Burglary at zone 7
Zone 8: Burglary at zone 8
Every event via SMS is time and date stamped. For customized texts
EasyLoad software is required, texts set at zone description section.
System fail texts displayed via SMS:
AC fail
Low Battery
AC fail restored
Low Battery restored
(More events are included)
Figure 3: SMS sample

7
5. Commands 200 in programming mode
Location Function
200 and 00 Display control panel type & software version
200 and 04 Erase (reset) the events history
200 and 05 Restore all codes to factory default
200 and 10 (SMS) Displays current setting LInE or Cell (SMS Mode)
200 and 11 (SMS) Sets to PSTN line (displays LInE) (PSTN SMS)
200 and 12 (SMS) Sets to mode GSM (displays CELL) (GSM mode)
200 and 20 Display current SMS language. En for English
200 and 21 Set English as the SMS language
200 and 22 Set Hebrew as the SMS language
200 and 30 Activate ON output (until disabled)
200 and 31 Deactivate ON output
200 and 32 Activate A1 output (until disabled)
200 and 33 Deactivate A1 output
200 and 44 Set panel to four (4) zones Mode
200 and 48 Set panel to eight (8) zones Mode
200 and 50 (Dial) Displays current settings LInE or CELL to dial on alarm
200 and 51 Set PSTN line for dialing (when answer siren sound is heard)
200 and 52 Set GSM line for dialing (when answer no siren sound)
200 and 69 Restore program to default
200 and 70 Not valid for LED keypad
200 and 71 Nor valid for LED keypad
200 and 72 Download zone description & logo only
200 and 77 Set panel to PC Communicate Mode
200 and 78 Arm panel from programming mode
200 + 10 displays current system setting; Line or Cell (Cell = GSM cellular)
200 + 11 sets PSTN LINE (displays Line by keypad display)
200 + 12 sets GSM (displays CELL by keypad display)
SMS via GSM Restrictions: Only English SMS even if for LINE Hebrew has
been set. Via PSTN LINE can send English or other languages (Hebrew) SMS.
When set to use GSM dialing to Central Station is disabled.
For LINE (via PSTN) SMS, address 008 (Service Center number) must be
programmed.
For GSM SMS address 008 is not relevant.
Save the SIM number at your phone:
For fast identify the SMS source create e new Contact in your mobile, apply
your favorite name like My GisMo or similar.

8
6. GisMo LEDs indications
Green LED Status - Indicates the GSM processor is operating. Must light
Red LED Net - Indicated the GSM network status, see modes in the below
table, wait while until unit registered to network.
Red LED status Description Note
Slow blinking every 2
seconds
GSM is registered and
connected to the network
Ready for action
Fast blinking every 0.5
second
Wrong command
received
Power off, wait than
power on
Keypad 3 LEDs indications SMS via GSM
SMS by GSM in progress SMS is sent the Shunt LED (Orange)
blinks fast for 3 seconds
SMS by GSM succeed Armed, Shunt and Fire LEDs light ON
steady for 4 seconds status LED (Green)
blinks fast for seconds
SMS by GSM fail Armed and Fire LEDs light ON steady for
4 seconds
7. Operating
Connect the keypad
Connect the antenna. Check the GSM signal level (with your mobile)
Verify the SIM card and antenna are connected
Power up with AC power
Notice the Gismo module LEDs are on
Wait 2-3 minutes to allow the GSM registration process.
SMS testing hold down key 6 than hold down key 5 – Send SMS to all
subscribers
Dial testing hold down key 6 than hold down key 7 – Dial to all subscribers
8. SIM card
The SIM card socket is located on the Gismo board, refer to figure 1.
SIM card parameters: Generation 2 or 3 (not micro type), SMS enabled,
without voice message service, without charges limits (not must), caller ID is
enabled and unlocked, Pin Code disabled. See sample picture below

9
Figure 4: SIM card that fits
In Australia GisMo works and tested with Vodafone SIM card.
9. AV-4044, AV-4008, AV-4009, 4008DVR GSM texts
The AV-4044DVR, 4008DVR models are dedicated to be used with CCTV
system that includes DVR or NVR recording device, the DVR may fail form
certain faults, the AV-4000 system supervised the recording device and
reports ant fail by sending SMS.
Zone 1: Hard disk fault
Zone 2: DVR Ventilator / Temp fail
Zone 3: TCP/IP communication fail
Zone 4: Recording stop
Zone 5: PTZ control fail
Zone 6: High temp alert
Zone 7: DVR faulty 1
Zone 7: DVR faulty 2
10. News for version 1.05
Periodical signal tests is added, see address 005. The panel dials via PSTN
(land line).
In AV-4044, 4008 GSM if phone numbers programmed system dials them via
PSTN, when caller answer a siren sound is generated.
Periodic test at address 005:
00 = No test signal
01 = Not valid in GSM (test to central station GSM mode)
02 = Send SMS for test, works in GSM mode only
03 = Send test signal by SMS and to central station (to CS via PSTN)

10
11. Trouble shooting in GSM mode
Pro bl em Sol uti on
The GSM is not sending SMS after
programmed
- Check the SIM card you used with unit.
Try to send SMS with the same SIM from
your mobile phone.
- Try to replace the antenna
- Check the local GSM signal level
The GSM is used to work fine, after a
while not responding and not sending
SMS
- The SIM provider (like Orange, Vodafone)
has poor radio coverage in the region.
- Try other provider (with better GSM
coverage) SIM card.
- Change the antenna location
- Other option is to use high gain GSM
antenna.
- Check that the SIM card has funds to
support SMS sending
- The GSM modem received thunder hit and
requires software and hardware reset, or
been damaged. Requires factory repair
I replaced the SIM in the GSM and
notice unstable unit
New SIM in most cases must be activated
by the SIM card provider and load with
some money (for sending SMS and dial) in
order to work properly.
Call the SIM provider or check the SIM in
your working mobile phone if can call and
send SMS
This manual suits for next models
8
Other AV-GAD Control Panel manuals
Popular Control Panel manuals by other brands

CAME
CAME ZL65 installation manual

Potter
Potter PFC-3002T Installation and operation manual

SKY Agriculture
SKY Agriculture Vision II DUO Original instructions

Radionics
Radionics D279A Operation and installation guide

Dahua
Dahua ARC5402A-GW user manual

Eaton
Eaton BreakerVisu NZM-XMC-MDISP35-MOD Instruction leaflet

American Standard
American Standard Gold 824 user guide

Siemens
Siemens Second Wind Function manual

Fike
Fike Quadnet Engineering and Commissioning Manual

Roger Technology
Roger Technology B70 1DCHP quick start guide

Whelen Engineering Company
Whelen Engineering Company WeCanX CCTL7 installation guide

Pyronix
Pyronix Conqueror User instructions