Avanti S-Series User manual

AA
Confirm
Learn
Learn
Confirm
10-10102-XEN
Version: 3.0t
COM
NC
NO
+
-
+
-
1 1
2 2
3 3
44
55
66
77
88
OFF ON
1 1
2 2
3 3
44
55
66
77
88
OFF ON
E
SB
4W
2W
SB
4W
2W
Chain Black Red Rail
YellowYellow
Open Limit
Moter
Red
Black
Blue Blue
Close Limit
++
++
ANT GN D
Short Press: Enter Transmier Setup Menu (See )
Long Press (5 sec): Forced Relearn (See )
Installaon- and User Manual
S-Series Garage Door Opener
Control Panel
In Standby: Decrease or Increase Force Offset Values ( )
Press and together: Enter Funcon Setup Menu ( )
In Funcon Setup Menu: Scroll Funcons and Values ( )
In Transmier Setup Menu: Scroll Funcons ( )
G
D
D
C
In Standby: Acts as Run Buon (Open and Close Door)
In Setup Menus: Confirm Chosen Funcon or Value
In any Setup Menu: Exit Menu.In any Setup Menu: Exit Menu.
1
3
4
2
1
2
3
4
11
2
3
Panasonic
CR2016
3V
+
Panasonic
CR2016
3 V
+
Panasonic
CR2016
3V
+
Panasonic
CR2016
3V
+
B
Run Funcon
Venlaon / Holiday
Light / Transmier Coding
Run / Auto Close Override
Alternately Opens, Closes or Stops the Garage Door.
Short Press - Switches Courtesy Light ON and OFF.
Long Press (5 sec) - Refer to for details. Enter Transmier Setup Menu. C
Short Press - Iniates a Drive into Venlaon Mode
Posion. (Only available if Venlaon Funcon is
enabled.)
Long Press (3 sec) - Iniates Holiday Mode. Places Opener
into a dormant state aer reaching Close posion. Refer to
for details. (Only available if Venlaon Funcon
is disabled.)
If Auto-Close disabled - Funcons same as Buon .
If Auto-Close enabled - Funcons same as Buon , however Door will not
Auto-Close when opened from this buon. Press for 3 sec to acvate.
1
1
How to Change Baeries
Transmier Funcons Ex Factory
D
C
33
12
Every Button of a Transmitter can be programmed with a
different Function as Listed below:
1.1 Bulk Coding from Control Panel (see Pic 1.1)
1.2 Bulk Coding from coded Transmier (see Pic 1.2)
1) Bulk Coding same as Factory Seng. ( ) 2) Assign certain Funcons to certain Transmier Buon.
There are two ways to learn a new transmier:
1 Bulk Coding same as Factory Seng. ( ))
2 Assign certain Funcons to certain Transmier Buon.)
B
Long Press 5 sec
press once
Pic 1.1 Pic 1.2
1. On already coded Transmier Long press Light)
Funcon (Buon 3 on pre - coded Transmier) for 5
sec. Display shows , Courtesy LED Light begins to
flash.
2. Press new Transmier twice unl LED fast flashes. )
Learning Complete.
Bulk Coding - (TX learns Funcons as shown in )
Run Funcon - Open/Stop/Close ( see )
Venlaon / Holiday Mode Funcon ( see )
1. Short press on Opener,)
2. Long press 5 sec unl light starts flashing, Finished.)
B
B
B
1
3
Light Funcon ( see ) -
Run Funcon/Auto Close Override - ( see )
OPEN Funcon - Only OPENS Door
CLOSE Funcon - only CLOSES Door
1. Short press on Opener, )
2. Use and to choose the desired funcon (see List above ). )
Transmier Coding
Delete all TransmiersDelete all Transmiers
press twice press twice
BB
1.) On Display Press Buon . Display shows ,
Courtesy LED Light begins to flash.
2. Press new Transmier twice unl LED fast flashes. )
Learning Complete. B
B
2
4
Learn
Learn
Learn
Learn
Confirm
D
Values
Funcon Descripon
Safety Photo Beam
Automac Close
Funcon
Safety Beams must
be enabled!
8.2 kOhm Safety
Contact Strip
Disable Safety Beam
Enable Safety Beam in
CLOSE Direcon
Enable Safety Beam in CLOSE and OPEN
Direcon.
No Auto-Close
Running Speed of
Opener
Slow Stop Funcon
Full Power Mode
Courtesy Light
Illuminaon me
Paral reverse /
Full reverse
Signal Reverse /
Signal Stop
Venlaon
Mode Time
Venlaon
Re-Opening Height
Door Service Monitor
Car Park Mode
Maximum Run Time
Back Jump OFF
Opener Stops aer
30 sec Run Time
Aer reaching Close Posion, Motor drives back 3mm
to release pressure from door
Opener Stops aer
60 sec Run Time
Accessories wired to COM/NO Connector (Key-Switch, Card Readers, etc.) will only
trigger OPEN Funcon. Hand Transmiers are NOT effected by this funcon.
If Door is out of Balance, Light will
flash during run to warn user
OFF
OFF
OFF
If door is idling in
VenlaonPosion,
shows in Display.
At press TX in Close
Direcon,Door will: Stop
Aer Hing Obstrucon,
Door will: Fully Reverse
Aer Hing Obstrucon,
Door will: Paral Reverse
At press TX in Close Direcon,
Door will: Reverse
1 min 2 min 3 min
Aer setup, will start.
Follow Steps .
30 sec / 180 sec30 sec / 180 sec
15 sec /
90 sec
05 sec /
30 sec
Low Speed
Tip Up Door
Speed
No Slow
Stop
High Speed
Disable
Safety Strip Enable Safety Strip
Funcon Setup
Aer setup, will start.
Follow Steps .
Aer setup, will start.
Follow Steps .
Outside Menu Funcons
Factory Reset: Switch off opener first. Iniate Reset by pressing and power on unl Display shows . Previouslycoded TX will not be deleted.
Holiday Mode: Press Holiday Funcon (Buon 2 on Bulk-Coded TX) for 3 seconds. Places Opener in a dormant state AFTER closing. is displayed.
Safety Beam Funcon
not enabled
If Safety Beam is acvated by passing car or person:
Door automacally closes aer 5/15/30 sec.
5
5
5
With acvated Venlaon Mode: Short Press Venlaon
Mode Buon on Transmier (2nd Buon on Bulk Coded
Transmier), Door will close completely, and then re-
open between 2-18 cm for Venlaon Purposes. Aer set
15/30/45/60/75/90 min door will automacally close.
OFF
Funcon not available in this version
Height of
Venlaon Slit
-
If Courtesy Light is switched on by Hand Transmier Light
Funcon, it will not automacally switch off.
Forced Relearn: Drive Door into ANY Posion but CLOSE. Long Press for 5 sec unl Display shows . See for further instrucons.
1.) To Enter Funcon Setup Menu: press at the same me.3.) Now choose value with and . Confirm
chosen value by pressing .
4.) To Exit Funcon Setup Menu at any me: press .
2.) Use and to scroll up and down through the funcons.
Press to select the desired funcon.
5
If Safety Beam is NOT acvated by passing car or person:
Door automacally closes aer 30/90/180 sec.
Short Slow
Stop
Long Slow
Stop
Blinking Output
3s Delay
Output same as
Courtesy Light
OFF Steady Output
3s Delay
External Flash Light
Output
Learn
Learn
Safety Photo Beam Open/Stop/CIose
OnIy"OPEN" Funcon
Transformer
Baery Backup
Door in Door
Coax Antenna
Connecon PIan
If accessories connected
to COM/NO are required
to ONLY trigger the
OPEN direction, Mode
needs to be set to .
This does NOT effect any
Hand Transmitter
Functions.
Run Buon: Open and Close Door. Connuos Press
overrides Safety Beam in Close Direcon.
Warning Light 24V AC
Max. 2A
8.2 kOhm Safety
Contact Strip
++
--
230V AC
NN
LL Relay
24V AC
Warning Light 230V AC
++
++
LAMP
SB
4W
2W
24V NOCOMSBRS
NC
CO M
C
D

M10
1
1Assemble Rail, Mount Control Unit and Running Unit, Tension Chain
Mount Brackets and Rail
M12
6
3b
3a
5a
5b
< 50mm
34
clickclickclick
clickclickclick
5
OK √
G
3 sec
4
Running Unit
2
Control Unit
2
Install Track NOT HIGHER
than 50mm above highest
arcing point of Door Panel!
CLOSE the Door by hand, then slide the Stopper as shown in drawing
into the carriage unl “click” is heard. Then firmly ghten the lock screw.
Connect to Power Supply. Courtesy Light begins to flash. is shown in Display.
Long Press Transmier Buon 1 for 3 seconds unl Light Fast Flashes.
1.) Door will AUTOMATICALLY RUN TWO (2) Complete Cycles ...
... (Close, Open, Close, Open) and then Stop in Open Posion.
Learning Complete when Blinking and exnguishes.
Pull Release Lever and make sure Running Unit is engaged.
OPEN the Door by hand, then slide the Stopper as shown in drawing
into the carriage unl “click” is heard. Then firmly ghten the lock screw.
Fine Tune Safety Offset Value
Safety Offset Value determines how easily the door Safety Reverses/Safety
Stops when hing an obstrucon. In order to prevent “ghosng” on a big,
badly sprung or worn, out door, Safety Value needs to be set to a higher value
(max.= ). In order to achieve a more sensive Safety Reversing, Safety
Offset Value needs to be set to a lower value (min.= ). Safety Offset Values
can be fine tuned at any me.
Fine Tune Safety Offset Value
1.) At any me, Press or . The
current Safety Offset Value is
shown.
2.) Press to increase or to
decrease the Value, being the
most sensive being the least
sensive value.
FTrouble Shoong
In case of an unusual incident, the Courtesy LED light triple
flashes, and an Error Code is displayed as below:
1.) Safety Photo Beam
obstructed by
Obstacle.
2.) Safety Photo Beam
malfunconing or not
installed correctly.
3.) Safety Photo Beam
not installed, but
Safety Photo Beam
Funcon enabled.
1.) Remove Obstacle.
2.) Replace
Malfunconing Device
or check Installaon.
3.) Install Safety Photo
Beam or disable Safety
Photo Beam Funcon.
1.) Safety Contact Strip
obstructed by Obstacle.
2.) Safety Contact Strip
malfunconing or not
installed correctly.
3.) Safety Contact Strip
not installed, but Safety
Contact Strip Funcon
enabled.
1.) Remove Obstacle.
2.) Replace
Malfunconing Device or
check Installaon.
3.) Install Safety Contact
Strip or disable Safety
Contact Strip Funcon.
1.) Adjust door balance.
2.) Turn off funcon
(be aware of the
Risks involved).
Maximum Run Time
Exceeded.
1.) Check and clear
reason that causes the
opener
exceeding Run Time.
2.) Engage emergency
release.
3.) Adjust run me from
30 sec to 60 sec. by
funcon see .
1. Set Safety Offset )
Values higher ( ).
2. Adjust Door Balance )
and Door Installaon.
3. Choose a more )
powerful Opener Model.
1. Door hit an Obstacle )
during Open or Close
movement.
2. Door in improper shape.)
1. Remove Obstacle. )
same as ( ).
Same as .
Door imbalanced
when Funcon enabled.
G
D
1
During Learn or Re-Learn
of Force Values : Door
Hit an Obstrucon or
Exceeded Set Safety
Offset Values.
Engage Running Unit, Connet to Power Supply
Posion Close/Open Stopper Learning Travel & Force
Confirm
Learn
3.) To confirm new Safety Offset
Value press .
4.) To leave without changes wait 10
seconds or press .
Table of contents
Other Avanti Garage Door Opener manuals
Popular Garage Door Opener manuals by other brands

Mighty Mule
Mighty Mule MMW200 Programming installation instructions

CAME
CAME MR8106 Installation tips

Craftsman
Craftsman 139.53990D owner's manual

SkyLink
SkyLink ATOMS Series user manual

Automatic Technology
Automatic Technology HiRO GDO-12 installation manual

Sears
Sears Craftsman 139.53910 owner's manual