SPECIFICATIONS GUIDE Rack Bracket For PM PDUs
To Contact Avocent Technical Support: Visit www.avocent.com 590-631-501A
Avocent and the Avocent logo are registered trademarks of Avocent Corporation or its affiliates in the U.S. and other countries. ©2010 Avocent Corporation.
1
For technical support, visit:
www.avocent.com/support
For document downloads, visit:
www.avocent.com/manuals
The illustrations in this specifications guide
are supplemental to the documentation
included with your Avocent Power
Management Power Distribution Unit
(PM PDU). The illustrations display the
dimensions for each model of PM PDU with
rack mounting brackets attached.
Horizontal PM PDUs
The illustrations for the horizontal PM PDUs are on
the following pages of this guide:
3-outlet models ................................. page 2
6-outlet models ................................. page 3
10-outlet models ............................... page 4
For specific rack mounting instructions, refer to either
the PM PDU Horizontal Power Strip Quick Installation
Guide or the Avocent PM PDU Installer/User Guide.
Vertical PM PDUs
The illustrations for the vertical PM PDUs are on the
following pages of this guide:
20-outlet models ........................ pages 5-6
24-outlet models .............................. page 7
Rack mounting bracket ................... page 8
For specific rack mounting instructions, refer to either
the PM PDU Vertical Power Strip Quick Installation
Guide or the Avocent PM PDU Installer/User Guide.
SPECIFICATIONS GUIDE Rack Bracket For PM PDUs
To Contact Avocent Technical Support: Visit www.avocent.com 590-631-501A
Avocent and the Avocent logo are registered trademarks of Avocent Corporation or its affiliates in the U.S. and other countries. ©2010 Avocent Corporation.
2
1.64 (41.7mm)
0.85
0
0.23
1.48
18.2 (462.3mm)
8.27 (210.1mm)
(437.1mm)17.21
9.73 (247.1mm)
6x 0.25 (6.4mm)
18.87 (479.3mm)
6x 0.50 (12.7mm)
PM 2000 PDU Models
PM2001H-401
PM2003H-401
PM 3000 PDU Models
PM3001H-401
PM3003H-401
SPECIFICATIONS GUIDE Rack Bracket For PM PDUs
To Contact Avocent Technical Support: Visit www.avocent.com 590-631-501A
Avocent and the Avocent logo are registered trademarks of Avocent Corporation or its affiliates in the U.S. and other countries. ©2010 Avocent Corporation.
3
6x 0.50 (12.7mm)
0.85
0
18.12 (460.2mm)
1.48
0.23
1.64 (41.7mm)
6x 0.25 (6.4mm)
9.89 (251.2mm)
8.27 (210.1mm)
17.21 (437.1mm)
PM 2000 PDU Models
PM2002H-401
PM2004H-401
PM2005H-403
PM2005H-404
PM2005H-406
PM2006H-401
PM 3000 PDU Models
PM3002H-401
PM3004H-401
PM3005H-403
PM3005H-404
PM3005H-406
PM3006H-401
SPECIFICATIONS GUIDE Rack Bracket For PM PDUs
To Contact Avocent Technical Support: Visit www.avocent.com 590-631-501A
Avocent and the Avocent logo are registered trademarks of Avocent Corporation or its affiliates in the U.S. and other countries. ©2010 Avocent Corporation.
4
0
0.36 (9.1mm)
5.87 (149.1mm)
1.53 (38.9mm)
1.48
0
18.2 (460.2mm)
0.23
0.85
6x 0.50 (12.7mm)
18.87 (479.3mm)
6x 0.25 (6.4mm)
PM 1000 PDU Models
PM1009H-401
PM1010H-401
PM1011H-xxx*
PM 2000 PDU Models
PM2007H-401
PM2008H-401
PM2009H-xxx*
PM 3000 PDU Models
PM3007H-401
PM3008H-401
PM3009H-xxx*
* The actual part number for
these models ends with the
country-specic code and
power cord type (for example,
-001 is used for North America
and includes an L6-20 cord).
SPECIFICATIONS GUIDE Rack Bracket For PM PDUs
To Contact Avocent Technical Support: Visit www.avocent.com 590-631-501A
Avocent and the Avocent logo are registered trademarks of Avocent Corporation or its affiliates in the U.S. and other countries. ©2010 Avocent Corporation.
5
37.28
0
41.53
8.03
8.53
7.53
9.03
37.78
38.78
0
38.28
4.78
1.10(2.8mm)
46.09(117.1mm)
2.20
(5.6mm)
3.14
(8.0mm)
4.50
(11.4mm)
2.50
(6.4mm)
PM 1000 PDU Models
PM1012V-401
PM1013V-401
PM1014V-xxx*
* The actual part number for these
models ends with the country-
specic code and power cord type
(for example, -001 is used for North
America and includes an L6-20 cord).
SPECIFICATIONS GUIDE Rack Bracket For PM PDUs
To Contact Avocent Technical Support: Visit www.avocent.com 590-631-501A
Avocent and the Avocent logo are registered trademarks of Avocent Corporation or its affiliates in the U.S. and other countries. ©2010 Avocent Corporation.
6
0
44.53
(113.1mm)
11.03
11.53
10.53
12.03
40.78
41.28
41.78
40.28
0
(19.8mm)
7.78
1.10 (2.8mm)
52.00 (132.1mm)
2.20 (5.6mm)
1.70(4.3mm)
3.14
(8.0mm)
4.50
(11.4mm)
2.50
(6.4mm)
PM 1000 PDU Models
PM1001V-401
PM1002V-401
PM1003V-401
PM1004V-401
PM1005V-401
PM1006V-401
PM1007V-401
PM1008V-401
PM 2000 PDU Models
PM2001V-401
PM2002V-401
PM2003V-401
PM2004V-401
PM2005V-403
PM2005V-404
PM2005V-406
PM2006V-401
PM 3000 PDU Models
PM3001V-401
PM3002V-401
PM3003V-401
PM3004V-401
PM3005V-403
PM3005V-404
PM3005V-406
PM3006V-401
SPECIFICATIONS GUIDE Rack Bracket For PM PDUs
To Contact Avocent Technical Support: Visit www.avocent.com 590-631-501A
Avocent and the Avocent logo are registered trademarks of Avocent Corporation or its affiliates in the U.S. and other countries. ©2010 Avocent Corporation.
7
4.25
4.75
5.75
5.25
0
61.25
61.75
60.75
60.25
(79.8mm)
3.14
66.00 (1,676.4mm)
2.20 (55.9mm)
1.70
(43.2mm)
(1,555.8mm)61.25
1.10
(27.9mm)
2.37
(60.2mm)
2.50 (63.5mm)
4.50 (114.3mm)
PM 2000 PDU Models
PM2010V-401
PM2011V-401
PM2012V-xxx*
PM 3000 PDU Models
PM3010V-401
PM3011V-401
PM3012V-xxx*
* The actual part number for these models
ends with the country-specic code and
power cord type (for example, -001 is
used for North America and includes an
L6-20 cord).
SPECIFICATIONS GUIDE Rack Bracket For PM PDUs
To Contact Avocent Technical Support: Visit www.avocent.com 590-631-501A
Avocent and the Avocent logo are registered trademarks of Avocent Corporation or its affiliates in the U.S. and other countries. ©2010 Avocent Corporation.
8
TYP
.625
1.700
.525
10X
2.475
.250
3.450
1.500
1.190
3X
.250
1.500
.625
=2.500
3X
TYP
12X R
4X .625
.213
.125
.625
.225
.510
10X.250
MIN BEND RAD
2.500
.125
4.500
.625
.625
.850
1.475
2X .250
10X R.125
.510
.225
.850
3X 4X
4X .975
4X
.250
.213
3X
.250
1.600
1.190
.225
4X
4X R.125
RMK-57
Rack mount bracket included with vertical rack PDUs

This manual suits for next models

52

Popular TV Mount manuals by other brands

The Guitammer Company BK-DTM supplementary guide

The Guitammer Company

The Guitammer Company BK-DTM supplementary guide

peerless-AV SMARTMOUNT ST680-S manual

peerless-AV

peerless-AV SMARTMOUNT ST680-S manual

KSL UKR2EN227 quick start guide

KSL

KSL UKR2EN227 quick start guide

FONESTAR STV-671N instruction manual

FONESTAR

FONESTAR STV-671N instruction manual

Kanto FMX3 user manual

Kanto

Kanto FMX3 user manual

LG WM-B840H owner's manual

LG

LG WM-B840H owner's manual

Nordic DELTACO ARM-1203 user manual

Nordic

Nordic DELTACO ARM-1203 user manual

arkitect AFMGM15 instruction manual

arkitect

arkitect AFMGM15 instruction manual

Helios TL64 Assembly instructions

Helios

Helios TL64 Assembly instructions

Secura QMF320-B2 instruction manual

Secura

Secura QMF320-B2 instruction manual

ONKRON G120 user guide

ONKRON

ONKRON G120 user guide

Xavax 111361 operating instructions

Xavax

Xavax 111361 operating instructions

Atlantic Technology System 20 LCR instruction manual

Atlantic Technology

Atlantic Technology System 20 LCR instruction manual

Ross neo manual

Ross

Ross neo manual

Elived YD1004-A Installation instruction

Elived

Elived YD1004-A Installation instruction

AVF 469267 manual

AVF

AVF 469267 manual

GEM Electromagnetic Lock Specifications

GEM

GEM Electromagnetic Lock Specifications

Sanus Systems PFFP Assembly instructions

Sanus Systems

Sanus Systems PFFP Assembly instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.