Awilco multiplex IP-EFOY-GATEWAY Installation guide

REV 1.5.0 - Copyright by Dipl.-Ing. Janus Piwek, Ingenieurbüro Piwek
AWILCO-MULTIPLEX
Yderholmvej 64
DK-4623 Ll. Skensved
Tel.: +45 5656 5400
Fax: +45 5656 5405
mail@awilco-multiplex.dk
www.awilco-multiplex.dk
IP-EFOY-GATEWAY
Technical Overview - EN

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
1 Introduction .............................................................................................................................................. 4
2 Firmware update description.................................................................................................................... 5
2.1 V0.8.3 ............................................................................................................................................... 5
2.2 V0.7.1 ............................................................................................................................................... 5
2.3 V0.6.7 ............................................................................................................................................... 5
3 Technical Data ........................................................................................................................................... 6
4 IP Configuration ........................................................................................................................................ 7
5 Description Periphery ............................................................................................................................... 8
5.1 Front panel ....................................................................................................................................... 8
5.2 Back panel ........................................................................................................................................ 9
6 Supported Protocols ............................................................................................................................... 10
7 EFOY PRO Compatibility .......................................................................................................................... 10
8 Getting started ........................................................................................................................................ 11
9 Use-Case.................................................................................................................................................. 14
9.1 „Green“ Off-Grid 48V „Power Over Ethernet“ power supply for wireless base stations............. 14
9.2 Portable EFOY Pro power supply with UMTS-Router for remote control applications .................. 15
9.3 Off grid power supply for wireless internet service provider (3.5 / 5 GHz base stations).............. 16
10 Description web interface................................................................................................................... 17
10.1 Web site - General...................................................................................................................... 17
10.2 Web site –IP .............................................................................................................................. 18
10.3 Web site - Security ..................................................................................................................... 19
10.4 Web site - SNMP ........................................................................................................................ 20
10.5 Web site - EFOY Supervisor ........................................................................................................ 20
10.6 Web site - EFOY Setup................................................................................................................ 23
10.7 Web site - EFOY Status ............................................................................................................... 25
10.8 Web site - EFOY Errors ............................................................................................................... 27
10.9 Web site - Info............................................................................................................................ 28
10.10 Email Notification Service .......................................................................................................... 30
10.11 TCP-UART-BRIDGE-MODE .......................................................................................................... 33
10.12 Off-the-shelf SNMP based monitoring solution......................................................................... 34
10.13 SNMP EFOY PRO Fuel Cell Remote Control................................................................................ 36

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
List of figures
Figure 1: Front panel.......................................................................................................................................... 8
Figure 2: Back panel........................................................................................................................................... 9
Figure 3: Schematic Installation....................................................................................................................... 11
Figure 4: IP-Configuration Menu...................................................................................................................... 12
Figure 5: PC's static IP-Configuration ............................................................................................................... 12
Figure 6: Login IP-EFOY-GATEWAY website...................................................................................................... 13
Figure 7: IP-Configuration IP-EFOY-GATEWAY.................................................................................................. 13
Figure 8: Green Power Supply.......................................................................................................................... 14
Figure 9: Fuel cell power supply for portable applications .............................................................................. 15
Figure 10: Pilot project - Off grid power supply for internet service provider................................................. 16
Figure 11: Web site - General .......................................................................................................................... 17
Figure 12: Web site - IP .................................................................................................................................... 18
Figure 13: Web site - Security .......................................................................................................................... 19
Figure 14: Web site - SNMP ............................................................................................................................. 20
Figure 15: Web site - 1st generation EFOY Supervisor..................................................................................... 21
Figure 16: Web site -2nd generation EFOY Supervisor .................................................................................... 21
Figure 17: Web site –1st generation EFOY Setup............................................................................................ 23
Figure 18: Web site –2nd generation EFOY Setup........................................................................................... 24
Figure 19: Web site - EFOY Status .................................................................................................................... 25
Figure 20: Web site - EFOY Errors .................................................................................................................... 27
Figure 21: Web site –1st generation EFOY Info ............................................................................................... 28
Figure 22: Web site –2nd generation EFOY Info.............................................................................................. 28
Figure 23: Website email notification.............................................................................................................. 30
Figure 24: Email delivered successfully............................................................................................................ 31
Figure 25: Email not delivered successfully ..................................................................................................... 31
Figure 26: Email Client ..................................................................................................................................... 32
Figure 27: TCP-UART-BRIDGE-MODUS............................................................................................................. 33
Figure 28: Tactical Network Map ..................................................................................................................... 34
Figure 29: Live EFOY PRO graphs overview...................................................................................................... 35
Figure 30: SNMP Chart..................................................................................................................................... 36

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
List of tables
Table 1: Electrical Data....................................................................................................................................... 6
Table 2: Mechanical Data................................................................................................................................... 6
Table 3: Environment conditions ....................................................................................................................... 6
Table 4: IP default settings ................................................................................................................................. 7
Table 5: Description front panel ........................................................................................................................ 8
Table 6: Description front panel ........................................................................................................................ 9
Table 7: TCP/UDP Protocols ............................................................................................................................. 10
Table 8: Protocol RS232 ................................................................................................................................... 10
Table 9: EFOY PRO compatibility...................................................................................................................... 10
Table 10: Description web site - General ......................................................................................................... 17
Table 11: Description web site - IP................................................................................................................... 18
Table 12: Description web site - Security......................................................................................................... 19
Table 13: Description web site –SNMP ........................................................................................................... 20
Table 14: Description web site - EFOY Supervisor............................................................................................ 22
Table 15: Description web site - EFOY Setup ................................................................................................... 24
Table 16: Description web site - EFOY Status ................................................................................................... 25
Table 17: Description web site - EFOY Errors ................................................................................................... 27
Table 18: Description web site - Info................................................................................................................ 29
Table 19: Notification event............................................................................................................................. 30
Table 20: Configuration fields Email notification ............................................................................................. 31
Table 21: Description event protocol............................................................................................................... 32
1 Introduction
The IP-EFOY-GATEWAY serves for remote control of a single SFC EFOY PRO fuel cell over the TCP/IP protocol.
At this the entire fuel cell parameter defined by the SFC EFOY PRO technical data sheet are readout continu-
ously over the RS232 interface. These data sets are provided to the customer for control application in dif-
ferent formats.
•SNMP
•XML
•HTML web site
•Email
•TCP-UART-Bridge-Mode (direct EFOY Pro remote command line interface terminal)
•TCP socket services can be developed on request
Furthermore, the IP-EFOY-GATEWAY gives the customer the opportunity to set up/reconfigure the EFOY PRO
fuel cell either within a local area network or over the internet by using the web site. There is no need for
further software installation.
The customer benefits from a simple and intuitive web menu navigation to preconfigure the fuel cell ex ante
or in a live running system.
However, the greatest benefit of the IP-EFOY-GATEWAY solution is that it makes it possible to give your
EFOY PRO fuel cell an IP address and that it can be integrated in a given IP network very quickly without any
limitations. From now on statically scheduled service tours are minimized and can be coordinated much
better since EFOY PRO fuel cell's parameter/states may be retrieved from each location and 24 hours a day.

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
2 Firmware update description
2.1 V0.8.3
•Firmware supports now SFC EFOY PRO 800/800 DUO and 2400/2400DUO
•Dynamic web data update interval on the web site can be adapted
2.2 V0.7.1
•Firmware supports now SFC EFOY PRO v11.10 with CONFIG command adaptation, but also back-
ward compatibility is assured
2.3 V0.6.7
•As default setting the IP-Address is bound over DHCP
•Additional EFOY data fields are read-out and displayed on the web site
◦Service fluid level
◦Temperature stack, fuel cell, heat exchanger
◦Connected fuel cell type (EFOY PRO 600 … 2200 XT)
◦Warranted operating hours (in charge mode) for the particular fuel cell
•Email Notification Report
◦If service fluid level <10%
◦If warranted operating hours (in charge mode) reached

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
3 Technical Data
Data
Range
Comment
Power consumption
~1W
Input voltage range
8V - 42V
•Allowed with 12V/24V batteries
•Power supply on terminal block and over EFOY
PRO data interface as well
Ethernet
•10/100BASE-T IEEE802.2 compatibility
RS232 (1 port)
•Communication EFOY PRO with 9600 Baud
Table 1: Electrical Data
Data
Range
Comment
Housing size (W x H x D)
105 mm x 33 mm x 102 mm
Housing material
Aluminium(silver anodised)
Weight
330g
Options
Table 2: Mechanical Data
Data
Range
Comment
Ambient temperature
-25 °C … +70 °C
Table 3: Environment conditions

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
4 IP Configuration
The following 5 shows the default settings of the IP-EFOY-GATEWAY.
By pressing the „Default“ switch button 5 seconds (see Figure 1) you can restore the default setting.
DHCP
Enabled since firmware version v0.6.7
IP address
192.168.96.210
Subnet mask
255.255.255.0
Gateway
192.168.96.1
Primary DNS
192.168.96.1
Secondary DNS
0.0.0.0
Table 4: IP default settings

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
5 Description Periphery
5.1 Front panel
L1
Power supply on
L2
1Hz heart beat, system
L3
Data communication EFOY Pro ↔ IP-EFOY-GATEWAY
L4
Not used
Default
Switch button must be pressed > 5 seconds, to restore default setting
RS232
Communication IP-EFOY-GATEWAY ↔ EFOY PRO
•just use with appropriate adaptor (available on request in Cabel-Kit)
LAN
Ethernet 10/100BASE-T (cables available on request in Cabel-Kit)
Table 5: Description front panel
Figure 1: Front panel

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
5.2 Back panel
Ext. Power
External power supply 8-42V
•Inverse-polarity protection
•TVS Diode >54V
•Power supply filter
Table 6: Description front panel
Figure 2: Back panel

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
6 Supported Protocols
Protocol
Comment
HTTP
•Configuration
•Fuel cell states
DCHP Client
•Automatic IP configuration
SNMP v2c
•Remote control EFOY PRO
SMTP
•Email notification service
Protocol stack EFOY PRO
•Communication with EFOY PRO over RS232
TCP-UART-BRIGE-MODE
•Remote communication with EFOY PRO over terminal command line
interface
Socket Server Service
•Optional on request
Table 7: TCP/UDP Protocols
Protocol
Comment
Protocol stack EFOY PRO
•Communication with EFOY PRO over RS232
Table 8: Protocol RS232
7 EFOY PRO Compatibility
Fuel Cell
Comment
EFOY PRO
600/1600/2200/2200 XT
•Compatible with EFOY PRO versions equal or greater than QB date
2011-03-24
EFOY PRO 800/2400/DUO
•Compatible with EFOY PRO versions equal QB date 2012-11-11
Table 9: EFOY PRO compatibility

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
8 Getting started
Figure 3 depicts schematically the cabling diagram of the IP-EFOY-GATEWAY to other communication devices
and EFOY PRO periphery.
Figure 3: Schematic Installation

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
As a start please follow the following steps to set up the network configuration properly. The IP-EFOY-
GATEWAY's default IP-Address is “192.168.96.210”.
Use your browser on initial installation or after a default reset to access IP-EFOY-GATEWAY's web server.
First you have to set up network settings to be conform with your local network.
1. Connect the IP-EFOY-GATEWAY RJ-45 interface labelled with “ETH” with the grey cable to your PC's
network interface
2. Reconfigure the IP configuration under menu “Internet protocol version 4” of your PC's network
interface and then press “properties” (see Figure 4)
3. Choose the following IP configuration for your PC (see Figure 5).
Figure 4: IP-Configuration Menu
Figure 5: PC's static IP-Configuration

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
4. Open the browser and enter the default IP address of the IP-EFOY-GATEWAY (see Figure 7).
5. Choose menu item “IP” on the left of the website and enter the default login and password com-
bination (see Figure 6 - Default user name: “admin” and default password: “00000”)
6. Afterwards choose new static IP-Configuration for your given network (see Figure 7). If you set the
“DHCP” check box, the IP-Configuration may be accomplished by a DHCP server in the local net-
work automatically.
7. Now you may disconnect the network cable from your PC and reconnect it to a router or wireless
router.
8. Now please open your browser again and enter the IP-EFOY-GATEWAY's IP-Address previously con-
figured under item 6
9. Now you should have access to the web server over your local network
Figure 7: IP-Konfiguration IP-EFOY-GATEWAY
Figure 6: Login IP-EFOY-GATEWAY website

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
9 Use-Case
9.1 „Green“ Off-Grid 48V „Power Over Ethernet“ power supply for wireless base
stations
Figure 8: Green Power Supply

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
9.2 Portable EFOY Pro power supply with UMTS-Router for remote control
applications
Figure 9: Fuel cell power supply for portable applications

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
9.3 Off grid power supply for wireless internet service provider (3.5 / 5 GHz base
stations)
Figure 10: Pilot project - Off grid power supply for internet service provider

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
10 Description web interface
10.1 Web site - General
Note
Description
1
•Device name
•name will be used by the email notification service
2
•Web data poll interval for dynamic data on web site in milliseconds
3
•Port for TCP-UART-BRIDGE-MODE (1024-65535)
4
•Start/Stop TCP-UART-BRIDGE-MODE
5
•Save settings
6
•IP-EFOY-GATEWAY restart
Table 10: Description web site - General
Abbildung 1: Webseite - General
Figure 11: Web site - General

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
10.2 Web site –IP
Note
Description
1
•MAC address IP-EFOY-GATEWAY
2
•Host name IP-EFOY-GATEWAY
3
•DHCP client service enabled/disabled
4
•IP address IP-EFOY-GATEWAY (automatic bound via DHCP)
5
•Gateway in LAN (automatic bound via DHCP)
6
•Subnet mask (automatic bound via DHCP)
7
•Primary DNS Server (automatic bound via DHCP)
8
•Secondary DNS Server (automatic bound via DHCP)
9
•Save settings
Table 11: Description web site –IP
Figure 12: Web site - IP

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
10.3 Web site - Security
Note
Description
1
•User name
2
•Password(maximum 9 signs)
3
•Password confirmation
4
•Save settings
Table 12: Description web site –Security
Figure 13: Web site - Security

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
10.4 Web site - SNMP
Note
Description
1
•System name (may be readout via SNMP default OID)
2
•System location (may be readout via SNMP default OID)
3
•System contact (may be readout via SNMP default OID)
4
•Community name for read SNMP values (OIDs)
5
•Community Name for write SNMP values (OIDs) currently not used
6
•Save settings
Table 13: Description web site –SNMP
10.5 Web site - EFOY Supervisor
The EFOY Supervisor overview gives the customer further configuration and remote control opportunities as
well. Some options differ from 1st to 2nd EFOY PRO generation.
•EFOY PRO restart
•EFOY PRO default settings
•EFOY PRO display language
•EFOY PRO error list
Figure 14: Web site - SNMP
Table of contents