Axis AXIS T95A00 User manual

ENGLISH DEUTSCH ITALIANO ESPAÑOL
INSTALLATION GUIDE
FRAN
Ç
AIS
AXIS T95A00 Dome Housing
AXIS T95A10 Dome Housing


AXIS T95A00/T95A10 Dome Housing Page 3
ENGLISH
AXIS T95A00/T95A10 Dome Housing
The AXIS T95A00/T95A10 Dome Housing can be used in both indoor and outdoor camera
installations. Follow these instructions to complete the installation of the AXIS T95A00/T95A10
Dome Housing and Axis network camera.
Warning! High voltage - the electrical connection must be made by an authorized electrician.
Please observe relevant national and local regulations for the installation.
•“Package Contents” on page 4
•“Installation” on page 5
•“Technical Specifications” on page 16
Safety Rules
Only qualified technical personnel may install this device.
• Disconnect power before any technical work on the appliance.
• Do not use old or worn out power cables.
• Never make changes or connections that are not shown in this handbook; improper use of
the appliance may cause serious hazard and may damage the product.
• Use original spare parts. Non-original spare parts could cause fire, electrical discharge, or
other hazards.
• Before installing the device, check the supplied material to make sure it corresponds with
the order specification.
• Please retain this document for future reference.
Axis Network Cameras
The AXIS T95A00/T95A10 Dome Housing supports the following camera models:
Camera Model: Note:
• AXIS 213 PTZ Before you begin, make sure that the AXIS
T95A00/T95A10 Dome Housing package contents, and
the required cables, tools, and documentation are avail-
able. See “Package Contents” on page 4.
• AXIS 214 PTZ
• AXIS 215 PTZ
• AXIS 231D+/232D+
• AXIS 233D

Page 4 AXIS T95A00/T95A10 Dome Housing
Package Contents
Large box:
(1) AXIS T95A00/T95A10 Dome Housing
Small box:
(2) Domes - transparent and smoked
(1) Fastening ring for dome
(1) Rubber gasket for dome
(4) M3x10mm screws for fastening ring
Plastic bag:
(1) Plate for cable glands
(1) Gasket for the cable gland plate
(1) M20 cable gland
(1) M16 cable gland
(1) M12 cable gland
(1) Plastic nut for M20 cable gland
(1) Plastic nut for M16 cable gland
(1) Plastic nut for M12 cable gland
(3) M3x10mm screws
(3) M3x8mm screws
(4) M4x10mm screws
(3) M3 nuts
(4) M4 nuts
(4) Lock washers
(1) 3mm Allen key
Plastic bag:
(1) Desiccant salt bag
Additional parts:
(1) Power cable for AXIS 213 PTZ, AXIS 214 PTZ, and AXIS 215 PTZ
(1) Ethernet cable with 90 degree angle for AXIS 231D+/232D+

AXIS T95A00/T95A10 Dome Housing Page 5
ENGLISH
Tools/ Parts not included
Other required parts
Note:
Not all screws provided are required for all camera installations.
Installation
Follow these steps indoors before the installation outdoor to save time at the installation site.
Attach Universal Adaptor to camera
1. Remove the top cover of the housing (with four screws) from the housing using the 3mm allen
key.
2. For AXIS T95A00 Dome Housing only - remove the two connectors (with black and blue cables)
attached to the circuit board on top of the Universal Adapter.
3. Loosen the three screws holding the Universal Adaptor. Rotate slightly and remove the
Universal Adaptor from the housing.
4. Attach the Universal Adaptor to the camera. For details see page 14.
Note:
Do not install the camera in the housing at this point. Transport it carefully to the place of
installation first.
Phillips screw driver
Ceiling bracket for AXIS 231D+/232D+ (supplied with the network camera)
Adjustable wrench
Mounting bracket See www.axis.com for available brackets and accessories
Power cable Examples:
AWG20, 100-240 VAC cable (AXIS T95A00 Dome Housing)
AWG22, 24 VAC cable (AXIS T95A10 Dome Housing)
Network cable CAT 5 shielded twisted pair (STP) cable recommended
Soft cloth Recommended for protecting the dome while installing the housing
Top cover Black cable Blue cable
Universal Adaptor

Page 6 AXIS T95A00/T95A10 Dome Housing
Fix the dome cover to the housing
Place the fastening ring over the dome. Insert the four
10mm M3 screws, so you hold the ring, the dome
cover, and the gasket together. Fix the dome cover
(transparent or smoked) at the bottom of the housing.
AXIS 213 PTZ, AXIS 214 PTZ, and AXIS 215 PTZ power connection
Connect the (provided) power cable to the 12 VDC output as shown in the picture.
AXIS T95A00/T95A10 Dome Housing output 12V DC
Camera power cable Housing power connector
black
red
GND
12 V
fastening ring
Housing
Rubber gasket
Dome
Fastening ring
Network camera power cable
12V DC
brown cable
power connector

AXIS T95A00/T95A10 Dome Housing Page 7
ENGLISH
AXIS 231D+/232D+ and AXIS 233D power connection
1. Unplug the connector from the 12 VDC power supply opposite the bracket opening as shown in
the illustration below.
2. Remove the 2-pin green connector block from the cables.
3. Connect the cable to the camera’s power connector as described below:
AXIS 231D+/232D+
• AXIS T95A00 Dome Housing (24V DC)
• AXIS T95A10 Dome Housing (24V AC)
Connect the brown cable to the 24V AC/DC pins on the AXIS
231D+/232D+ connection module (see illustration).
Note:
The AXIS 231D+/232D+ connection module contains a
rectifier so the cables can be connected either way.
24V
~
+
~
-
12 VDC
power connector
Brown cable
remove green
connector
block
AXIS 231D+/232D+ Connection module
24V AC/DC

Page 8 AXIS T95A00/T95A10 Dome Housing
AXIS 233D
As the camera is not yet installed in the housing, this is a preparatory step
showing how to connect the brown cables from the 24V connector to the
8-pin green connector block (supplied with the camera). When the
camera is later installed in the housing, this connector block will then be
connected to the camera itself. Referring to the connection diagram on
the right, connect the brown cables for your version of the T95A.
• AXIS T95A00 Dome Housing (24V DC)
Connect +24V to AC/DC+
Connect -24V to GND/DC-
• AXIS T95A10 Dome Housing (24V AC)
Connect +24V to AC/DC+
Connect -24V to AC.
Prepare the cable gland plate
Fix the 3 cable glands to the cable gland plate and place the cable gland plugs on them. Insert the
four M3 screws through the gasket and plate.
The preparation for the network camera installation is now complete.
AXIS 233D
Connector
AC
AC/DC+
GND/DC-
12V out
GND
Line out
GND
Line/Mic in

AXIS T95A00/T95A10 Dome Housing Page 9
ENGLISH
Install the mounting bracket
Note:
Make sure all cables are in place but not powered, before you install the bracket. Keep
cables unpowered until the installation is complete.
1. Install the bracket for the AXIS T95A00/T95A10 Dome Housing on a wall and make sure that
the screws and plugs are appropriate for the wall (wood, metal, concrete, or any other), and
suitable for the weight of the housing. To install the bracket in the correct direction, see figure
below.
2. Pull a sufficient length of the cables through the bracket for the housing and camera
(approximately 50 cm).
Note:
Visit the Axis web site at www.axis.com for a comprehensive list of the available brackets
and accessories.
3170
182
150
81
230
14
140
110
77
9
14

Page 10 AXIS T95A00/T95A10 Dome Housing
Mount the housing to the bracket
Notes:
• Ensure that the bracket is securely fastened, and cables are pulled through it before mounting the
camera housing. Ensure that no power is connected to the cables.
• It is recommended that you place a soft, clean cloth (not included) into the dome to ensure it
remains clean until the time when you need to mount the camera.
1. If the top cover of the housing was attached to facilitate transportation, detach it again at this
point.
2. Position the AXIS T95A00/T95A10 Dome Housing against the bracket, making sure to pull the
cables (power, Ethernet, and I/O cables if applicable) into the housing, and tighten the two
25mm M5 allen key screws (included with the bracket).
3. Pull the cables through the cable glands, and secure the hole in the bracket with the cable
gland plate. Ensure the cables are securely fastened in the cable glands.
4. Remove the protective cloth (if you have used one) from the dome, and remove traces of dust.
Install the camera in the housing
1. Make sure power is disconnected from the housing before installing the camera.
2. Connect the network cable to the Ethernet port in the camera.
3. Connect the power cable to the camera.
4. If applicable, connect the I/O cables to the connectors as described in the installation guide
supplied with the camera.
5. Lower the Universal Adaptor with the attached camera into the AXIS T95A00/T95A10 Dome
Housing and tighten the 3 screws.
6. Connect power to the housing as described below.
•“For AXIS T95A00 Dome Housing” on page 11
•“For AXIS T95A10 Dome Housing” on page 12

AXIS T95A00/T95A10 Dome Housing Page 11
ENGLISH
For AXIS T95A00 Dome Housing
Attach the power cable (100-240V AC) to the housing.
Earth the housing applying the two supplied cables
to the cover and body using the M3 screws and
toothed washers.
100-240V AC
100-240V AC input
Out 24V DC
Overview of complete installation
N
L
GND
Black Blue
In 100-240V AC
Out 230V AC
Out 12V DC
Brown cable
(not required for camera
installation)

Page 12 AXIS T95A00/T95A10 Dome Housing
For AXIS T95A10 Dome Housing
Attach the power cable (24V AC) to the housing.
The safety wire should remain fastened during service.
Place the desiccant bag on the side of the housing
away from cables and electrical components.
Note:
For AXIS 231D+/232D+:
Place the connection module in a suitable position on
top of the bracket, away from cables and electrical
components.
Overview of complete installation
24V AC Out
N 24V AC
L 24V AC
GND
12V DC Out
Brown
Red
24V AC In
Desiccant bag

AXIS T95A00/T95A10 Dome Housing Page 13
ENGLISH
Complete the installation
1. Check that all cables and wires in the housing are properly connected.
2. Replace the top cover of the housing and tighten the screws using the supplied Allen key.
3. Connect the AXIS T95A housing to the power supply (110-240VAC or 24VAC - depending on
the version you are using).
4. Follow the instructions in the Installation Guide to install the camera on the network.
The installation is now complete.
The Axis network camera installation guide is shipped with the camera or available from the Axis
website at www.axis.com.
To remove the sunshield
Remove the three screws on the side of the sunshield with a Phillips screw driver; remove the screw
on the top center of the cover plate with the 4 mm Allen key.
It is recommended that this is done after the installation.

Page 14 AXIS T95A00/T95A10 Dome Housing
Mount the Universal Adaptor to the camera
The Universal Adaptor consists of five plates.
Universal adaptor when assembled
Fixed plate
Spacer plate
AXIS 233D plate
Moving plate
Spacer plate
A
B
C
D
E
F
G
H
I
L
M
N
A
B
C
D
E
F
G
H
I
L
M
N
11
22
A
B
C
D
E
F
G
H
I
L
M
N
A
B
C
D
E
F
G
H
I
L
M
N
11
22
PM3
PM7-PM8
PM2-PM5
PM8 PM4
PM3
PM3
PM7
PM10
PM6
PM6
PM6
PM10
PM1-PM10
PM7
PM7
PM4
PM4
PM7
PM7
PM4
PM8
PM9-PM11 PM2-PM5
PM2-PM5
PM9-PM11
PM1-PM10
PM1-PM3
Fixed plate (view from below) Spacer plate Spacer plate
AXIS 233D plate
Moving plate
PF1
PF1
PF1
PF2
PF3
PF2
PF3
PF1
PF2
PF3 PF3

AXIS T95A00/T95A10 Dome Housing Page 15
ENGLISH
For AXIS 233D
1. Adjust the height of the spacer plates to hole F+1 on the spacer plate
(See illustration).
2. Place the camera within the four ears of the Universal Adaptor and
screw it onto place. The adaptor is supplied already configured for the
AXIS 233D.
For AXIS 213 PTZ
1. Detach the AXIS 233D plate by removing the three nuts.
2. Adjust the height of the spacer plates to holes B+2 on the spacer plate.
3. Place the AXIS 213 PTZ on the Moving plate.
4. Fasten the AXIS 213 PTZ to the two PM 11 holes with two screws.
For AXIS 214 PTZ
1. Detach the AXIS 233D plate by removing the three nuts.
2. Adjust the height of the spacer plates to holes E+1 on the spacer plate.
3. Place the AXIS 214 PTZ on the Moving plate.
4. Fasten the AXIS 214 PTZ to the three PM5 holes with three screws.
For AXIS 215 PTZ
1. Detach the AXIS 233D plate by removing the three nuts.
2. Adjust the height of the spacer plates to holes E+2 on the spacer plate.
3. Place the AXIS 215 PTZ on the Moving plate.
4. Fasten the AXIS 215 PTZ to the four PM 10 holes with four screws and nuts.
For AXIS 231D+/232D+
1. Unscrew the fixed plate from the Universal Adaptor.
2. Attach the ceiling bracket to the PF2 holes on the fixed plate.
You may find this easier to do by temporarily removing the
PCB from the top of the fixed plate (T95A00 only).
3. Pull the provided 90° angle Ethernet connector and
connection module cable through the center of the ceiling
bracket (supplied with the camera).
4. Connect the connection module cable and the angled Ethernet connector to the camera.
5. Guide the studs on the base of the camera into the holes on the ceiling bracket and rotate it to
fix in position.

Page 16 AXIS T95A00/T95A10 Dome Housing
Technical Specifications
General
Built in die-cast aluminium
Epoxypolyester powder paint
RAL9002 color
Lower dome in polycarbonate Smoked or transparent
Sunshield in ABS for outdoor use RAL9002 color
Mechanical
External dimensions with sunshield Ø 351 x 335 mm (13.8 x 13.2”)
External dimensions without sunshield Ø 314 x 322 mm (12.4 x 12.7”)
3 cable glands 1x M20 with Ø cable 3,5 - 7,5 mm (0.1 - 0.3”)
1x M16 with Ø cable 3,5 - 7 mm (0.1 - 0.3”)
1x M12 with Ø cable 5 - 10 mm (0.2 - 0.4”)
Other Protective gasket
Electrical
Fan assisted heater, operating temperature range:
15°C to 22°C (±3°C)
59°F to 71°F (±5 °F)
• AXIS T95A00 Dome Housing:
IN 230 V AC, consumption 44 W max
• AXIS T95A10 Dome Housing:
IN 24 V AC, consumption 24 W max
Internal power connectors • AXIS T95A00 Dome Housing:
IN 100/240 V AC, 50/60 Hz
OUT 12 V DC, 3 A max
IN 100/240 V AC, 50-60 Hz
OUT 24 V DC, 1.5 A max
• AXIS T95A10 Dome Housing:
IN 24 V AC, 50/60 Hz, OUT 12 V DC, 2 A max
Blower in continuous operation.
Related products
AXIS T95A61 Wall bracket
AXIS T95A64 Pole adapter
AXIS T95A67 Corner adapter

AXIS T95A00/T95A10 Dome Housing Page 17
ENGLISH
Environment
Indoor / Outdoor Operating temperature: -30° C to +50° C (-4° F to
+122° F)
Compliance
• CE according to EN61000-6-3, EN 60950, EN50130-4
• IP66 according to EN 60529
Package
Unit weight AXIS T95A00 Dome Housing / AXIS T95A10 Dome
Housing - 3.8 kg / 8.3 lb.
Package weight 4.2 kg / 9.3 lb.
Package dimensions (B x H x L) 38.5 x 38.5 x 47 cm / 15.1 x 15.1 x 18.5”


Boîtier de dôme AXIS T95A00/T95A10 Page 19
FRAN
Ç
AIS
Boîtier de dôme AXIS T95A00/T95A10
Le Boîtier de dôme AXIS T95A00/T95A10 peut être utilisé dans les installations de caméra
intérieures et extérieures. Procédez comme suit pour installer le Boîtier de dôme AXIS
T95A00/T95A10 et la caméra réseau Axis.
Avertissement : Haute tension - le raccordement électrique doit être effectué par un
électricien agréé. Veuillez respecter les réglementations nationales et locales concernant
l’installation.
•« Contenu de l’emballage » à la page 20
•« Installation » à la page 21
•« Caractéristiques techniques » à la page 32
Règles de sécurité
Seul un personnel technique qualifié est autorisé à installer ce dispositif.
• Débrancher du secteur avant de procéder à tout travail technique sur l’appareil.
• Ne pas utiliser de câbles d’alimentation anciens ou usés.
• Ne jamais effectuer de modifications ou de raccordements ne figurant pas dans ce manuel ;
toute utilisation inappropriée de l’appareil peut provoquer des dangers graves et peut
endommager le produit.
• Utiliser des pièces détachées d’origine. Les pièces détachées qui ne sont pas d’origine
peuvent provoquer des incendies, décharges électriques et autres dangers.
• Avant d’installer le dispositif, vérifiez le matériel fourni pour vous assurer qu’il correspond à
la spécification de votre commande.
• Veuillez conserver ce document pour vous y reporter ultérieurement.
Caméras réseau Axis
Le Boîtier de dôme AXIS T95A00/T95A10 est compatible avec les modèles de caméras suivants :
Modèle de caméra : Remarque :
• AXIS 213 PTZ Avant de commencer, passez en revue le contenu de
l’emballage Boîtier de dôme AXIS T95A00/T95A10 et
vérifiez que les câbles, outils et documentation
nécessaires sont disponibles. Cf. « Contenu de
l’emballage » à la page 20.
• AXIS 214 PTZ
• AXIS 215 PTZ
• AXIS 231D+/232D+
• AXIS 233D

Page 20 Boîtier de dôme AXIS T95A00/T95A10
Contenu de l’emballage
Grande boîte :
(1) Boîtier de dôme AXIS T95A00/T95A10
Petite boîte :
(2) Bulles - transparente et fumée
(1) Anneau de serrage pour la bulle
(1) Joint caoutchouc pour la bulle
(4) Vis M3x10mm pour l’anneau de serrage
Sac en plastique :
(1) Plaque pour les presse-étoupes
(1) Joint pour la plaque de presse-étoupe
(1) Presse-étoupe M20
(1) Presse-étoupe M16
(1) Presse-étoupe M12
(1) Écrou plastique pour le presse-étoupe M20
(1) Écrou plastique pour le presse-étoupe M16
(1) Écrou plastique pour le presse-étoupe M12
(3) Vis M3x10mm
(3) Vis M3x8 mm
(4) Vis M4x10 mm
(3) Écrous M3
(4) Écrous M4
(4) Rondelles frein
(1) Clé hexagonale 3 mm
Sac en plastique :
(1) Sac de dessicateur
Pièces supplémentaires :
(1) Câble d’alimentation pour AXIS 213 PTZ, AXIS 214 PTZ et AXIS 215 PTZ
(1) Câble Ethernet avec angle à 90 degrés pour AXIS 231D+/232D+
Other manuals for AXIS T95A00
2
This manual suits for next models
1
Table of contents
Languages:
Other Axis Security Camera manuals