MINI-MICRO ™ RECESSED UPLIGHT
Surface Mount Installation
RELEASE DATE
12-13-16
REFERENCE NUMBER
INS000933.1
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
Please refer to the low voltage
design guide at www.bklighting.
com/lvguide before installation for
proper wire selection.
TOOLS
NEEDED:
By Others
Warning Low Voltage Hot Surface
· Suitable for wet locations · Suitable for in ground installations
IMPORTANT LISTINGS AND CERTIFICATIONS
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
PVC Housing
Body
Faceplate
18 Ga. Wire
Surface Mount
Collar
INSTALLATION
Surface mount uplights are intended for installation in
wood, pavers, stone, and other hardscapes.
Not recommended for concrete pour
installations.
5/64” Allen Wrench
Waterproof Wire Connectors
Silicone
Flammable
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
Proper soil preparation is recommended before installation. See the DIG-IT guide at www.bklighting.com/dig-it for more information.
RELEASE DATE
12-13-16
REFERENCE NUMBER
INS000933.1
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
Finished grade
8 3/4”
2 window
faceplate
shown
Finished grade
8 3/4”
LINE 12V
FIXTURE
COM
Remote
Transformer
COM
Optical opening on
faceplate will align with
alignment arrows on
temporary cover
Optical opening on
faceplate will align with
alignment arrows on
temporary cover
Stability flange
Rebar or stake (by others)
Pea gravel or sand
Finished grade
Concrete
Stability flange
Rebar or stake (by others)
Pea gravel or sand
Finished grade
Concrete
Finished grade Concrete
Wire nuts must
clear opening
6”
min.
10. Mount faceplate to collar using (2) #6-32
screws (provided) with a 5/64” Allen wrench.
9. Make watertight connections using waterproof
wire connectors (By Others). Insert fixture and
low voltage wire into Power Pipe™.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
MINI-MICRO™ RECESSED UPLIGHT
Surface Mount Installation
LED - For use with 12VAC
remote transformer or magnetic
transformers only. B-K Lighting cannot
guarantee performance with third party
manufacturers’ transformers.
4. Align holes to final installation orientation.
Arrows on temporary cover point towards screw
location on faceplate for alignment purposes.
NOTE: Do not remove temporary cover until
installation of faceplate.
Finished grade
12”
Finished grade
8 3/4”
LINE 12V
FIXTURE
COM
Remote
Transformer
COM
Screws on faceplate will
align with alignment
arrows on temporary
cover
Stability flange
Rebar or stake (by others)
Pea gravel or sand
Finished grade
Concrete
Stability flange
Rebar or stake (by others)
Pea gravel or sand
Finished grade
Concrete
Finished grade
Concrete
Wire nuts must
clear opening
6”
min.
Finished grade
15”
6. Remove temporary cover and pull out remote
wiring.
2-1/4” O.D.
2-3/4” O.D.
2. Loop minimum of 6” of wiring inside housing to
allow for fixture service.
NOTE: Do not remove temporary cover!
Finished grade
Wire nuts must
clear opening
6”
min.
Screws on faceplate will
align with alignment
arrows on temporary
cover
7. Access remote wiring inside housing. Make
watertight connections using waterproof wire
connectors (By Others). Wire nuts must clear
opening. Insert fixture, wiring and connections
into housing. See wiring diagram.
5. Use a silicone based sealant (By Others) between
fixture and mounting surface.
1. Drill 2-1/4” diameter hole into mounting surface
at uplight installation location as per lighting
plan.
Do not exceed surface diameter, installation
relies on surface mount collar resting on surface
grade. Collar diameter is 2-1/4”. Surface mount
flange is 2-3/4” diameter.
Pull secondary wiring from remote driver.
3. Place housing into hole. Surface mount collar
should rest on finished surface grade.
NOTE: Do not remove temporary cover!
Core Drill Installation Instructions

Other B-K lighting Landscape Lighting manuals

B-K lighting SS User manual

B-K lighting

B-K lighting SS User manual

B-K lighting Precision2 HP2 Series User manual

B-K lighting

B-K lighting Precision2 HP2 Series User manual

B-K lighting UL Series User manual

B-K lighting

B-K lighting UL Series User manual

B-K lighting ALPS Series User manual

B-K lighting

B-K lighting ALPS Series User manual

B-K lighting MCKINLEY Series User manual

B-K lighting

B-K lighting MCKINLEY Series User manual

B-K lighting Denali Series User manual

B-K lighting

B-K lighting Denali Series User manual

B-K lighting ArtiStar Series User manual

B-K lighting

B-K lighting ArtiStar Series User manual

B-K lighting UL Series User manual

B-K lighting

B-K lighting UL Series User manual

B-K lighting Denali Series User manual

B-K lighting

B-K lighting Denali Series User manual

B-K lighting ADJUSTABLE WELL STAR User manual

B-K lighting

B-K lighting ADJUSTABLE WELL STAR User manual

B-K lighting ArtiStar Integral User manual

B-K lighting

B-K lighting ArtiStar Integral User manual

B-K lighting HUME User manual

B-K lighting

B-K lighting HUME User manual

Popular Landscape Lighting manuals by other brands

Cooper Lighting Generation CLB25MWW5C373 Specification sheet

Cooper Lighting

Cooper Lighting Generation CLB25MWW5C373 Specification sheet

AMP Lighting OrchardPro APL-3018-B-BZ Installation & maintenance guide

AMP Lighting

AMP Lighting OrchardPro APL-3018-B-BZ Installation & maintenance guide

LIGMAN BILLUND 4 installation manual

LIGMAN

LIGMAN BILLUND 4 installation manual

Catellani & Smith Syphaduepassi Assembly instructions

Catellani & Smith

Catellani & Smith Syphaduepassi Assembly instructions

HEISSNER L419-00 Instructions for use

HEISSNER

HEISSNER L419-00 Instructions for use

Cooper Lighting Lexington LXF70SR2554 Specification sheet

Cooper Lighting

Cooper Lighting Lexington LXF70SR2554 Specification sheet

Paradise Datacom GL22720 manual

Paradise Datacom

Paradise Datacom GL22720 manual

Lumo Teho Solar Premium operating instructions

Lumo

Lumo Teho Solar Premium operating instructions

V-TAC VT-8055 instruction manual

V-TAC

V-TAC VT-8055 instruction manual

Faro Barcelona TRAS Series manual

Faro Barcelona

Faro Barcelona TRAS Series manual

XanLite BOFE40WNW manual

XanLite

XanLite BOFE40WNW manual

Saxby Lighting PYRAMID instruction manual

Saxby Lighting

Saxby Lighting PYRAMID instruction manual

Conrad 64 90 06 operating instructions

Conrad

Conrad 64 90 06 operating instructions

SLV 231535 operating manual

SLV

SLV 231535 operating manual

STI solar Solar Stepstone instruction manual

STI solar

STI solar Solar Stepstone instruction manual

Brinkmann 822-0429-0 owner's manual

Brinkmann

Brinkmann 822-0429-0 owner's manual

Malibu Boats CM14P instructions

Malibu Boats

Malibu Boats CM14P instructions

Landscape Vibrations CRISP 6 install guide

Landscape Vibrations

Landscape Vibrations CRISP 6 install guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.