baby express be mine User manual

User’s Guide
be mine Dual Electric Breast Pump
baby express
making parenting a breeze
baby express
Please read this user’s guide carefully before using

Main features of the product
This electric breast pump is specially designed for breastfeeding mothers and babies. It simulates a
baby's suction motion and has nine adjustable suction levels. In addition, there are nipple traction
mode and nasal suction mode.
Stimulation / Suction / Bionics Mode Selection
Each mode has nine adjustable suction levels on each side which can be individually
adjusted with different suction levels. The newly added bionic mode simulates the
frequency of baby nursing to give the mother a more comfortable pumping experience.
Nipple Traction / Nasal Suction Mode
Nipple traction mode can help correct invaginated nipple. This is suitable for
postpartum mothers with flat nipple or invaginated nipple who cannot feed their baby
directly. (Warning: Expectant mothers should not use this mode).
The nasal suction mode can help suck out baby's thick mucus, relieve or eliminate
baby's nasal discomfort.
Frequency Adjustment
With three adjustable frequency, high, medium and low. Mothers can adjust the suction
rhythm according to their comfort.
Single / Dual Mode Selection
Conveniently touch to switch between single or double expression mode, giving you the
feasibility to have the option to express milk on either one or both side.
Do not use the breast pump in the shower.
Do not twist or tangle the silicone tubes.
If the device drops into water, please unplug it immediately and do not touch the pump control
device.
Any parts that are in direct contact with breast milk are personal care items and should not be
shared with other users.
Keep the charging cable far away from high-temperature surfaces.
If the product or charging cable is damaged, it must be replaced by professional personnel from
the manufacturer, maintenance department or similar department to avoid danger.
Important safety instructions

Do not place the pump motor unit near fire or open flame.
Do not place the pump motor device or charging cable into liquids, such as water, gasoline,
beverage, etc.
Do not charge product near fire or in an environment with a temperature over 45 °C.
Keep PE bags away from children, to avoid the hazard of suffocation.
Please charge the pump motor unit before using it for the first time.
Please clean and sterilise all components before use. Immediately wash after use and keep the
parts dry. The pump motor unit and charging cable cannot be cleaned by water or sterilise.
Keep the product out of reach of infants.
Do not leave bottle tilted or overfilled when in use (do not exceed the maximum scale).
Please turn off the power when the pump control device is fully charged and when not in use.
When disassembling and cleaning, be careful not to lose any parts. During assembling, be sure to
assemble each component according to the assembly sequence. Any missing component or
improper assembly may cause the product to function abnormally or be unable to work.
Adjust the suction level to suit your comfort level.
Please disassemble all components of the product before sterilisation. Do allow the product
components to cool for about 20 minutes after the sterilisation is completed before assembling to
avoid damage.
Please use the breast pump under the guidance of doctors, nurses or certified personnel.
Do not over pump as it may cause injury to the breast.
In case of any pain caused by the use of this product, please consult with a medical staff
immediately.
A breast pump is a tool to help mothers in breastfeeding and should be used for the sole purpose
of expressing breast milk. Some new mothers may face blocked mammary gland (which can be
caused by congenital invaginated nipple), or insufficient milk supply. If faced with such problems,
it is recommended to seek professional advice to verify that the mammary gland is unblocked.
This product should only be used for the purpose described in this User’s Guide.
Any parts that are in direct contact with breast milk are personal care items and should not be
shared with other users.
Expectant mothers should not be using a breast pump unless otherwise advised by a medical
professional.
Precautions for use

Cleaning instructions
Please wash and sterilise any components that are directly in contact with breast milk before and
after use.
Please do not soak the pump motor unit and charging cable into the water for cleaning, only wipe
it with a clean cloth.
Please do not clean and sterilise the silicone tubes. The tube is only a vent pipe and does not come
in contact with breast milk. Clean its surface only. Water in the silicone tube may cause permanent
damage to the product.
Diaphragm, valve and massage cushion are made from food-grade silicone material; thus, do not
sterilise for an extended period of time to avoid ageing or deformation.
During assembling, be sure to assemble each component in the order of assembly. The
components to be sterilised: milk bottle, breast cushion, T-joint flange, diaphragm, travel cap,
valve and pump cover. Except for the pump motor unit, charging cable and silicone tubes.
Be careful when cleaning the valve and the silicone diaphragm. If it gets damaged, the breast pump
will not be able to operate.
Lithium battery usage precautions
Dismantling, impacting, extruding or throwing into the fire are prohibited.
Do not put it under direct sunlight or in a hot environment.
Please do not use when there is any bulging.
Do not disassemble batteries. Some components of lithium batteries are flammable and harmful.
They can cause damage, fire, rupture or explosion.
Do not disassemble, open, chop or pierce the battery or battery pack with metal.
Only use the original adapter provided for the product to charge, otherwise it may be hazardous.
Do not leave the batteries charging after it is full for an extended period of time.
Before discarding the product, please remove the batteries.
Lithium batteries can only be replaced by authorized service providers. Replacing the wrong type
of batteries can be hazardous. The product must be powered off when removing batteries.
Disposal of abandoned batteries should be in accordance with national environmental protection
laws in the country that the user resides in.

Important: The diaphragm, valve, silicone tube and massage cushion are wear and tear components,
if there is any damage to these parts, please contact our distribution centres to purchase the
replacements.
1
4
1
2
2
2
2
2
2
TPE
- -
-
--
-
Silicone
Silicone
Silicone
Description of package contents and components
Please check the quantity of the content before use. If there is any missing part, please contact the
seller
Silicone
PP
PP
PP
2
2
2
PP
PPFlange Cap
No. Material
Food Grade
Food Grade
Food Grade
Food Grade
Food Grade
Food Grade
Food Grade
Food Grade
Food Grade
Food Grade
RemarkQuantity
-20˚C ~ 120˚C
-20˚C ~ 130˚C
-20˚C ~ 120˚C
-20˚C ~ 100˚C
-20˚C ~ 200˚C
-20˚C ~ 200˚C
-20˚C ~ 200˚C
-20˚C ~ 200˚C
-20˚C ~ 200˚C
-20˚C ~ 200˚C
TemperatureComponent Name
Diaphragm
Charging Cable
Silicone Tube
Adaptor
Pump Motor Unit
Bottle Cap
Baby Bottle (160ml)
Valve
Pump Cover
Massage Cushion
T-Joint Flange
baby express

Expression Indicator
Operation Panel
Stimulation Indicator
Nipple Traction, Nasal Suction Mode: Press and hold to enter into nipple traction
or nasal suction mode, quick press to switch between modes.
Frequency Switching: A total of three different levels; low frequency, medium
frequency and high frequency cycle. The initial default is medium frequency.
Single and Double Suction Switch: Touch to choose single or double suction
function.
Stimulation Mode, Expression Mode and Bionic Mode: after 2 minutes of
stimulation mode, the mode will switch to expression mode automatically. (The
suction level for both sides is individually adjustable under the double suction
function).
The default duration of expression mode is 28 minutes, and for the bionic mode is 30
minutes.
Pause Button: Touch the button to pause the breast pump, second touch to resume
working. The unit will power off automatically after 3 minutes when left in pause mode.
Power Button: Press and hold the power button to on the pump motor unit (The
pump motor unit will turn off automatically in 30 minutes after the last operation).
Touch to off.
Bionic Mode Indicator
Nipple Traction Indicator
Nasal Aspiration Mode Indicator
Right side power selection: Click to increase the power; Click to decrease
the power.
Left side power selection: Click to increase the power; Click to decrease
the power.
baby express

If using double sides expression mode, insert two silicone tubes into
the air vent holes at the bottom of the pump motor unit.
Put the silicone diaphragm into the T-joint flange and press the rim
to ensure a perfect seal. Then put the flange cap on the diaphragm,
press it down tightly to fit it on.
Insert the massage cushion into the T-joint flange and press the rim
to ensure a perfect seal.
Product assembling sequence
Insert the valve on the cylinder under the T-joint flange, push it in until
it fits tightly.
Attach the bottle into the bottom of the T-joint flange until it’s tightly
joined.
If using single expression mode, insert one silicone tube into the left
air vent hole at the bottom of the pump motor unit.
Put on the pump cover. (Please remove the pump cover when using
it, and put in on when storing).
Note: Check all the components are correctly assembled to ensure a perfect seal state before
each use.

Relax in a comfortable chair, leaning slightly forward.
Press the assembled pump body against your breast. Make sure your nipple is centred so that the
massage cushion crease an airtight seal.
The machine default is set to stimulation mode at level 1. Please press to change to Expression
mode and Bionic mode. (In stimulation mode, the machine will operate for about 2 mins and
automatically switches to expression mode, and the machine will automatically shut down after the
30 minutes cycle is completed).
You can press button or button to adjust suction strength at any time when using.
( button and button have nine levels of suction strength which can be adjusted individually).
How to find your personal comfort suction level?
Increase the suction gradually until you feel slight discomfort (not a pain), then slightly reduce the
suction.
To end the session, press the power button lightly to switch off; the status light will automatically
turn off.
Disassemble and clean all parts of the breast pump after use (except for the motor, adapter,
charging cable and silicone tube).
Nasal Aspiration Operations: Press and hold button to change to Nasal Suction Mode. Connect a
silicone tube to the bottom of the nasal aspirator. Cover the small hole on the side the nasal aspirator
with one finger when using. Then gently insert the top end of the nasal aspirator into the nasal cavity
of the baby.
Operation instruction
3.7V
50 - 165mmHg
35 - 150 times/min
2500mAh 9.25Wh
5V===2A
75 - 320mmHg
15 - 95 times/min
Dual Electric Breast
Pump
Specification
Description:
Input Voltage:
Expression
Intensity:
Expression
Frequency:
Stimulation
Frequency:
Battery Capacity:
Battery Voltage:
Stimulation
Intensity:

Massage the nipples to ensure the milk ducts are clear. Start
pumping from the lowest level and allow some time for response.
Please recheck if all components are correctly installed. Take note
on the T-joint flange, diaphragm, valve and tube etc. are connected
firmly.
Make sure both ends of the silicone tube is correctly inserted into
the motor unit and flange cap.
Check if the valve is opened or damaged.
If the breast pump still cannot work even if after it is connected with
the power adapter, please contact the distributor or designated
maintenance shop.
Ensure that the nipple is aligned in the middle of the flange.
Start from level 1 and increase the level step by step, to find an
appropriate level for you.
Please stop pumping and obtain professional advice if the above
method cannot solve the problem.
No milk out
Low suction
or no suction
Not working
Feel painful
during use
Troubleshooting Method
Problem
The table is applicable to mature healthy infant and for reference only. Please contact the hospital
or a professional institute for more information and advice.
Breast milk will expand after freezing, do not fill the feeding bottle or milk bag to the brim with milk,
please reserve at least 1/4 space for expansion.
Please indicate the milk pumping date/time on the milk bottle or milk bag.
To minimise nutrition loss, please thaw the frozen milk in the refrigerator compartment or put the
milk bottle/bag under running warm water with a temperature lower than 37˚C. After thawing, heat
the milk bottle/bag with milk inside under hot water of temperature lower than 50˚C. (You can use a
bottle warmer to thaw frozen milk as well).
Thawing breast milk with a microwave oven or under high temperature is not recommended.
Please swirl milk bottle/bag to mix the separated milk before feeding.
16˚C to 26˚C
-20˚C to -10˚C
-10˚C to 0˚C
0˚C to 4˚C
Up to 8 hours (Ideal situation)
Up to 12 months
2 weeks - 6 months
72 hours - 8 days (Ideal situation)
Up to 4 hours (Ideal situation)
Shelf Life
Air-Conditioned Room
Chest Freezer / Deep Freezer
Freezer Compartment
Refrigerator Compartment
Fresh Breast Milk
28˚C to 35˚CRoom Temperature
Tips for breast milk storage & warm
Troubleshooting
Note: Always do a smell and/or taste test to verify freshness
Table of contents
Other baby express Breast Pump manuals

baby express
baby express be mini User manual

baby express
baby express be mini x User manual

baby express
baby express be nude pro User manual

baby express
baby express be free User manual

baby express
baby express be nude User manual

baby express
baby express be free User manual

baby express
baby express mini x User manual