CLJ-03A03 Type Temperature And Humidity
Laser Particle Counter
Executing standard: Q/320500BSK009-2005
OPERATING MANUAL
ISO9001: 2000 CERTIFIED
SUZHOU CLEANING TECH. RESEARCH INSTITUTE
BAISHEN TECHNOLOGY (SUZHOU) CO., LTD.
Attention: Before operating CLJ-03A03 type
temperature and humidity Laser
Particle Counter, user must read this
operating manual carefully, please!
Keeping the manual for reference.
1
Welcome to use CLJ-03A03 Type Temperature And Humidity Laser Particle
Counter, thank you warmly entering into our companys consumer team!
1. Introduction :
CLJ-03A03 type temperature and humidity temperature and humidity laser
particle counter is set up 6 particles channel which can show directly testing
&inspecting data, by microprocessor control. It possess the store and print function it
can proceed testing and inspecting data's disposal to computer by RS232 /RS485
joint .
CLJ-03A03 counter is adopted laser diode to test the particle for lamp house , the
laser diode's light irradiate at particle and is scattered. it focus on diode by condensing
lens, than convert electric pulse signal by optical signal, impulse signal's height is
particle size measured value, and is taking count of meantime cover electronic after
amplifier enlarging , according to particle size range ,the test is proceed.
CLJ-03A03 counter is built-in sensor of temperature and humidity with which we
can test T&RH.
2. Open the box acceptance check
2.1 This is an accurate test instrument. the product has already proceeded detection
before leaving the factory, the consumers can directly be used for particle's testing
and inspecting. when receiving goods, the customers should check the transportation
damage situation first, if no wrapping transportation damage situation, please retain
the packing material using for the transportation next time, the apparatus is testing
instrument which need to be proceed calibration once per year, at that time, you can
repeat using the wrapping.
2.2 spare part and accessories
Aluminium alloy suitcase : protect the apparatus from damage.
Motivity sampling head : it is used for disorderly flow environmental sampling
action, It can be measured the particle size distribution. especially ,portable
fixed-point particle test.
Filter: used for sensor's reset device to ensure sensor under no dust condition.
Charger: used for apparatus battery's charge.
RS232 port: between computer and printer's connection.
Matched compact disc: used for apparatus and computer application software.
2
Option accessory: Sampling bracket Printer.
3. Usage attention
3.1 The apparatus can not be using in active gas, rot gas environment, otherwise it
maybe bring blast danger and damage apparatus.
3.2 When using charger , pay attention to local voltage to prevent damage charger.
3.3 when using, the apparatus can not be grave impacted, otherwise, it will make
optical system damage and shell disrepair which affect usage.
3.4 The Apparatus is a laser product, if it has any trouble, please contact with
manufacturer, it can not be disassembled by oneself.
4. Panel display control button introduction
⑴Company registered mark
⑵Liquid crystal display monitor
⑶Test , run and stop button (RUN)
⑷Menu selection key
⑸ ⑹ Set up key
⑺Mains switch
⑻RS232/RS485 and print port
⑼Charge port
Tripod fixing screw hole
⑾Humiture test outlet
⑿Sampling outlet
Key position
State Run Menu πθ
Initial interface Run Menu 209E/ISO Reset Chinese English Shift
Menu Exit Select Up Down
Run Stop Menu N/A 209E/ISO Mode
Data reading Exit Data printing
Up Down
5. Displaying interface and panel function set up
3
A. Displaying interface
Put ON”at general mains switch (Open)
A.1 turn on
Screen display, interface is as follow:
(2), Menu key
Press menu key, screen display function is as follow:
Screen display
B. set time :
Press " "selection, move cursor to back of clock (Cursor is broken line)▽
Set up year, move cursor to |00-00-00 00:00. Press menu key, cursor is real line,
press " "Key to ascertain year, after setting up year , press menu key again,▽
cursor is broken line. Set up month, day, hour, minute according to up mentioned
operation.
Set up month, move cursor to 00-|00-00 00:00
Set up day, move cursor to 00-00-|00 00:00
Set up hour, move cursor to 00-00-00 |00:00
Set up minute, move cursor to 00-00-00 00:|00
周期
CLJ03A03
Particle Counter
Baishen Inc.
25.5
℃
55%
Battery
Print |yes 209E yes
Point 2 Times 2
Clock 02-05-09 11:10
Duration 1 Read
Cursor
4
C. Set up 209E clean degree differentiate Menu display
C.1 Set up 209E
Press " "Key, move cursor to back of 209E, choice "Yes "or "Not ", Press menu▽
key, cursor is real line. if select "Yes ": denote as select 209E functions, select "Not
" :denote as no 209E functions.
C.2 Set up the point
Press " "Key, move cursor to▽ point back, then press menu key, cursor is real line,
press " "key again, choice need the point, press menu key again, end setting up▽
point.
C.3 Fix each dot times
Press " "key, move cursor to times back, then press menu key, cursor is real▽
line, press " "key again, choice needed times, press menu key , end time setting▽
up.
周期
周期
Print yes 209E |yes
Point 2 Times 2
Clock 02-05-09 11:10
Duration 1 Read
Cursor
Print yes 209E yes
Point |2 Times 2
Clock 02-05-09 11:10
Duration 1 Read
Cursor
5
D. print setting up
Press " "key, move cursor to print back, press menu key, cursor is real line,▽
choose to yes or not, "Yes "denote needing to print, "No "Denote: does not print, then
press menu key, quit setting up.
E. cycle
Press "△"key, move cursor to the back of cycle, then press menu key, cursor is
real line, press "△"key again, choice the check and measure cycle (Unit : minute ),
press menu key after setting, end cycle setting.
F. read
周期
周期
Print yes 209E yes
Point 2 Times |2
Clock 02-05-09 11:10
Duration 1 Read
Cursor
Print |yes 209E yes
Point 2 Times 2
Clock 02-05-09 11:10
Duration 1 Read
Print yes 209E yes
Point 2 Times 2
Clock 02-05-09 11:10
Duration 1 |Read
6
This function is for read at all point time that stored data.
Press " "key, move cursor to in the front of read, press menu key. Press "▽ ▽
"key again to show each period of time's data one by one, after examining, press
run”to return beginning state.
G. detection count
After the each item function setting up, and the samplinging outlet is connected
sampler, then detect and count.
Primary display
(2), Menu key
Press run”key, enter into test, meanwhile, pump start up, after a minute, it stop, the
screen will display each particle consistence per minute (Add up)
Apparatus reset : after finishing operation, proceed apparatus reset, please
connect filter to samplinging outlet, filter arrow direction points to apparatus sampling
outlet, and come into running state till 0.5μm display for 0, At "Test spot :enter to test
point and name.
Press run”key again, enter into next minute test until the continuous operation to
end.
H. 209E determining
After pressing ”run key to enter into test mode, press" "Key into 209E
25.5℃55%
CLJ03A03
Particle Counter
Baishen Inc.
25.5
℃
55%
Battery
7
determining, screen will display the check number and time currently .after
testing ,quit 209E determining mode automatically .next test will need to press "
"key again. power supply can be closed between two 209E determinings, system
could save the check number and time currently automatically .If need set the check
number and time repeatedly, press " △" to make check number and time to set 1”
repeatedly, recover starting condition .
As the check number and time arrive setting value, the meter can calculate UCL
automatically
Cleanliness Comparison
ISO14644-1 FS-209E PCS/CF
0.5 5.0
5 100 100 -
6 1000 1000 7
7 10000 10000 70
8 100000 100000 700
9 >100000 >100000 >700
UCL:mean value 95% certainty factors (PCS/CF).
If the meter is connected to printer, meanwhile,it has already set up print mode, the
screen content and clean class will be printed.
I. charging
When quantity of electricity sign shows empty”, it need to be charged use
Point: 1 Times: 1 25.5 ℃55%
UCL0.5 5.0/28.3L ISO
47831 1593 8
8
charger (No use other charger to prevent damaging) 。red lamp light for charging,
green lamp light for full .
6. The software using illustration
CLJ03A03 can be connected with computer , the users can read the storage
content of CLJ03A03 by the software, convenient for proceeding report print and data
storage.
6.1 Connecting Port
CLJ03A03 RS232 serial port can be connected to computer's serial port by 9 pins
serial cables (port number is COM1).
6.2 Read storager content
open CLJ03A03 power supply, start computer and run CLJ03A. EXE.Choice "Online
operation "- "Read storager content ", if connecting is right, the user can read the past
store data from CLJ03A03 . CLJ03A03 will be showed "Computer link " "Uploading
data ", "Transfer completed "will be not showed on the liquid crystal screen till the
schedule bar of host computer is completed.
6.3 print
hook in small pane, then choose to print for the report printing.
6.4 Data's conservation and reading
choice "File "- "Save ", save the data content;
choice "File "- "Read ", can put in saving data content;
The data file format is "CSV "Format, it can be used Excel software
9
CLJ-03A03 Type Temperature And Humidity Laser Particle Counter
OPERATING MANUAL
SUZHOU CLEANING TECH. RESEARCH INSTITUTE
BAISHEN TECHNOLOGY (SUZHOU) CO., LTD.
Add: 31 Qihong Road, Tongyuan Road ,SIP Suzhou
Zip: 215006
Phone: +86-512-62522538
Fax: +86-512-62522938
http: //www.baishen.com
E-mail: [email protected]
2004 Printed in Suzhou

Popular Measuring Instrument manuals by other brands

RADIOMETER ABL 77 Series Service manual

RADIOMETER

RADIOMETER ABL 77 Series Service manual

Major tech MT715 instruction manual

Major tech

Major tech MT715 instruction manual

Knick Stratos Pro A2 COND Series user manual

Knick

Knick Stratos Pro A2 COND Series user manual

ZIEHL MINIPAN NS43V operating manual

ZIEHL

ZIEHL MINIPAN NS43V operating manual

Prosense FMM50-1001 operating instructions

Prosense

Prosense FMM50-1001 operating instructions

Beckhoff KM3701 Documentation

Beckhoff

Beckhoff KM3701 Documentation

Bosch GLM Professional 80 Original instructions

Bosch

Bosch GLM Professional 80 Original instructions

Pfeiffer Vacuum TPG 300 operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum TPG 300 operating instructions

Holman DRG001 user guide

Holman

Holman DRG001 user guide

GREEN INSTRUMENTS G3600 manual

GREEN INSTRUMENTS

GREEN INSTRUMENTS G3600 manual

Apera LabSen 371 user manual

Apera

Apera LabSen 371 user manual

Waeco MAGIC Control MTPM-100 Installation and operation manual

Waeco

Waeco MAGIC Control MTPM-100 Installation and operation manual

Campbell CR7 instruction manual

Campbell

Campbell CR7 instruction manual

PCE Health and Fitness PCE-PHM 12 user manual

PCE Health and Fitness

PCE Health and Fitness PCE-PHM 12 user manual

janitza UMG 96 RM-PN user manual

janitza

janitza UMG 96 RM-PN user manual

Zorg 3201 Installation & operating manual

Zorg

Zorg 3201 Installation & operating manual

VOLTCRAFT DT 2 L / k operating instructions

VOLTCRAFT

VOLTCRAFT DT 2 L / k operating instructions

Leuze AMS 304i Original operating instructions

Leuze

Leuze AMS 304i Original operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.