BALCO ILLUMITREAD 1531 User manual

ESI1531
08/07/12
BALCO, INC. ILLUMITREADTM
PHOTOLUMINUMESCENT EXIT DOOR,
PANIC BAR, MODEL 1531
Installation Instructions
The following installation instructions are very important. Read them carefully, and be sure you understand
themcompletelybeforeyoubeginanywork. Storethisproductinthehorizontalpositioninaclean,drylocation.
Storethisproductinaprotectedarea. Minimumlightexposurelevelnecessarytoachievephotoluminescence
of the signs is 1 Foot Candle.
Figure 1
Tools required :
Thisisalistoftoolsandmaterialsrecommendedfor
use in the installation of these directional signs.
These tools and materials are not provided by
Balco, Inc.
A. Clean Rags
B.Tape Measure
C. IsopropylAlcohol
D. Clean Bucket (for alcohol/water mix)
Parts:
1. DirectionalSign
Balco, Inc., 2626 S. Sheridan, PO Box 17249, Wichita, KS 67217
P (316) 945-9328; F (316) 945-0789; www.balcousa.com
PROCEDURES:
TheseinstructionsareapplicabletoExitDoor,Panic
Bars,model1531. Installindoorsonlyinalocationnot
exposedtodirectsunlight,liquidsprayortemperatures
outside the range of 50oF - 104oF (10oC - 40oC).
Ensure temperature of both the directional sign and
the surface to receive it is 60oF or higher at the time
ofinstallation. These panic barsarealuminum sheet
to which photoluminescent coating is applied. The
installer shall select the installation means suited to
the substrate.
STEP 1. Ensure that the surface to receive the
directional sign is free of dust, oil and other
contaminants. Wipe most aluminum, steel acrylic,
polycarbonate,andpainted/sealedsubstratestoreceive
thedirectionalsignwitha50/50solutionofisopropyl
alcohol and water. Routinely replace cleaning cloth
to insure proper cleaning. Some glossy surfaces
(certain paints and expanded rigid PVC board) may
benefitfromslightscuffing with a mild abrasivepad
prior to cleaning with the ispropyl alcohol/water
mixture. Allow the alcohol/water solution used to
clean the substrate to evaporate from the substrate
prior to applying the directional sign. Where heavy
oils or grease are present, a “degreasing” solvent
such as 3M™ Prep Solvent 70, 3M™ Citrus Base
Cleaner, mineral spirits, naphtha or similar solvents
are suggested to cut the oil. This should always be
followedwithanisopropylalcohol/watercleaningto
help ensure that any residue or film is removed.
FollowtheapplicableMSDSinstructionsforhandling,
storage and use of whichever primer or solvent is
selected.
STEP 2. Select the means of attachment. For
Balco,Inc.PhotoluminescentExitDoor,PanicBars,
an adhesive that the installer has determined to be

ESI1531
08/07/12 Page 2
satisfactory for the sign installation may be used. As an alternative, VHB tape or a double-sided tape which
theinstallerhasdeterminedtobesuitablemaybeusedtoaffixthesignstothesubstrate. Inaddition,mechanical
fasteners may be used, if appropriate. The installer shall determine the anchorage to be used, based upon its
suitability and the substrate to which the signs are affixed.
STEP 3. Selectanexitdoor,panicbar. Placetheselectedpanicbarintoitsinstalledpositionontheactuating
bar or touchpad. Ensure that the panic bar is straight and in the proper position on the substrate.
NOTE: ENSURE THAT THE PROPER POSITION OF THE PANIC BAR
HAS BEEN DETERMINED. ONCE THE PANIC BAR IS PRESSED ONTO
THE SUBSTRATE, REPOSITIONING OF THE PANIC BAR WILL BE
EXTREMELY DIFFICULT.
Figure

ESI1531
08/07/12
STEP 4. Using the anchorage determined to be suitable, attach the panic bar to the substrate, see Figure 2.
NOTE: LIMIT CONTROL OF AMBIENT ILLUMINATION LEVEL FOR
CHARGING BALCO, INC. PANIC BARS TO AUTHORIZED
PERSONNEL ONLY. EXTERNAL UNFILTERED FLOURESCENT
(OR EQUIVALENT) ILLUMINATION MUST BE PRESENT ON THE
SIGNS AT ALL TIMES OF BUILDING OCCUPANCY.
WARNING: MINIMUM ILLUMINATION TO CHARGE THE
PANIC BARS SHALL BE NOT LESS THAN 11 LUX (1
FOOTCANDLE) FOR ONE (1) HOUR. INSUFFICIENT
AMBIENT ILLUMINATION WILL RESULT IN FAILURE OF
THE PANIC BARS TO CHARGE AND TO PHOTOLUMINESCE.
Page 3 © 2012, Balco, Inc.

ESI1531
08/07/12
Balco, Inc. Photoluminescent Egress SystemsBalco, Inc. Photoluminescent Egress Systems
Balco, Inc. Photoluminescent Egress SystemsBalco, Inc. Photoluminescent Egress Systems
Balco, Inc. Photoluminescent Egress Systems
Operation, Cleaning and MaintenanceOperation, Cleaning and Maintenance
Operation, Cleaning and MaintenanceOperation, Cleaning and Maintenance
Operation, Cleaning and Maintenance
Facility Name:
Facility Location:
Operations/Maintenance Manager:
1. Introduction
Balco, Inc. photoluminescent exit path marking systems are illuminated using either natural or
artificiallightsources. Theperformanceofthephotoluminescentcomponentsisdependantupon
thelightexposure,bothintensityandduration. Thetypeoflightinginafacilityanditsbrightness
will determine the required duration of exposure to adequately charge the photoluminescent
components to achieve desired performance.
2. Operation
A. MINIMUMACTIVATIONSOURCETYPE: FluorescentIllumination.
B. MINIMUM ILLUMINANCE AT TARGET: 1 foot candle (11 lux).
C. MINIMUMACTIVATIONDURATION: 60minutes.
Ensure that the source lighting is controlled by authorized personnel only. Maintain adequate
light level and duration to properly activate photoluminescent components.
3. Cleaning
Establisharegularinspectionscheduleforthephotoluminescentcomponentsandcleanthemas
needed to prevent dirt, etc. from inhibiting the performance of the components. Balco, Inc.
recommends inspection at least once every year or after any particularly heavy use. Perform
inspections in accordance with applicable local and national code requirements.
Photoluminescentcomponentsattachedto floor assemblies may be cleanedbymopping,using
high-pressurewater (but notsteamcleaning) orwipingwith acleandamp cotton cloth. Usemild
detergents to clean the photoluminescent components, if necessary. Mild dish washing
detergentsorlaundrydetergentsarerecommended. Donotusehighlyalkalinedetergents,those
having a ph >8, or acidic cleaners, those having a ph <5. Do not use abrasive cleaners.
Photoluminescent components on walls or other assemblies or components may be cleaned
using clean water and a clean sponge or a clean cotton cloth. Rinse after applying detergent
solution. Wipe with a clean cotton cloth to dry.
4. Maintenance
Inspectexitpathmarkings,obstaclemarkingsandphotoluminescentstairnosingsfordamaged
componentsandtoensurethatphotoluminescentcomponentsremainproperlyattachedtotheir
substrateandthatnolooseningofanchorsordelaminationofphotoluminescentcomponentshas
occurred.
Replacedamagedcomponents. Tightenanylooseanchors. Handtighteningissufficient. Repair
delaminated photoluminescent components. Contact the factory for repair recommendations.
Delaminatedphotoluminescentcomponentsinstairnosingscanresultinatriphazardandshould
be repaired immediately.
Page 4

WARRANTYPOLICY
Balco,Inc. warrants to its purchasers that all productssoldbyit will be free from manufacturing and material
defects. Any defective product will be replaced or repaired free of any charge, provided a claim is brought
to our attention, in writing, within the established warranty period following the date of shipment by us and
provided our examination shows the product has failed under the terms of this warranty. The established
warrantyperiodforexteriorjointcoversystems(DuraflexTM) isfive(5)yearsprovidedthesystemsareinstalled
by a Balco Certified Installer. The established warranty period for grids and mats is two (2) years. The
establishedwarrantyperiodforallotherBalco,Inc.productsisone(1)year. Balco,Inc.willnotberesponsible
for installation costs involved in such repair or replacement. Balco, Inc. shall have no obligation under this
warrantyifowner subjects materialstoimproperconditions (refer toBalco'sinstallationinstructions) This is
inlieuofallotherwarranties,expressedorimplied,andisthesolewarrantyextendedbyBalco,Inc. Ourliability
underthiswarrantyislimitedtorepairorreplacementanddoesnotincludeanyresponsibilityforconsequential
orother damageofanynature. Itis furtheragreedand understoodthatthepricestated fortheseller's products
isconsiderationforthelimitation ofseller'sliabilityhereunder.
REGISTERED TRADEMARKS: BALCO, INC. PATENT NUMBERS:
"VINYLINES" "SAF-T-GLO" 5,782,044; 5,829,216; 5,832,678;
"METAFLEX" "SAF-TEN BEVEL" 6,014,848; 6,115,980; 6,581,347;
"SENTRY" "DURAFLEX" 6,942,419; 6,955,017; 6,962,026;
"ILLUMI-TREAD" "METABLOCK" 7,104,717; 7,856,781; 7,946,784;
"MICHAEL RIZZA COMPANY" 8,079,190; 8,245,471; 8,464,485;
8,607,519; 8,601,760; 8,646,235;
Fire Resistant Joint Covers Patents
Pending
Table of contents