Bard R-410A User manual

Form No. S3383-1112
Supersedes S3383-510
Page 1 of 8
Air Conditioner Compressor:
Reciprocating compressors with
crankcase heaters are standard on 2,
2½ and 3-ton models. Scroll
compressors are used on all other
models and no crankcase heaters
are required.
R-410A Refrigerant:
Designed with R-410A (HFC) non-
ozone depleting refrigerant in
compliance with the Montreal protocol
and 2010 EPA requirements.
ECM Indoor Blower Motor:
Features an electronically commutated
motor providing super-high efficiency,
low sound levels and soft-start
capabilities. The motor is self-
adjusting to provide the proper airflow
rate for a broad range of static
pressure in ducted installations without
user adjustment or wiring changes.
Aluminum Finned Copper Coils:
Grooved tubing and enhanced
louvered fin for maximum heat
transfer and energy efficiency.
Outdoor coil is constructed with
special corrosion resistant
hydrophilic fin stock with 2-layer
coating. (1st layer - blue acrylic
primer; 2nd layer - clear topcoat.)
Thermal Expansion Valves:
Models with reciprocating
compressors have bleed TXV,
models with scroll compressor have
non-bleed TXV.
Discharge Muffler:
Standard on 2½ and 3-ton models.
Liquid Line Filter Drier:
Protects system against moisture.
Compressor Control Module:
Built-in off-delay timer adjustable from
30 seconds to 5 minutes. 2-minute
on-delay if power interrupt. 120-
second bypass for low pressure
control, and both soft and manual
lockouts for high and low pressure
controls. Alarm output for alarm relay.
Phase Rotation Monitor:
Standard on all 3-phase models.
Protects against reverse rotation if
power supply is not properly
connected.
High & Low Pressure Switches are
Auto-Reset
Built-in lockout circuit resets from the
room thermostat. Provides commercial
quality protection to the compressor.
Pre-Painted 20 Gauge Zinc Coated
Steel Cabinet:
Cleaned, rinsed, sealed and dried
before the polyurethane primer is
applied. The cabinet is handsomely
finished with a baked on textured
enamel, which allows it to withstand
1000 hours of salt spray tests per
ASTM B117-03.
Pre-Painted 16 Gauge Zinc Coated
Unit Base:
The unit base is treated with the
same paint coatings as the cabinet
above, insuring years of service.
Top Discharge Outdoor Fan:
Efficiently moves air quietly for
effective heat exchange.
Electrical Components & Controls:
Readily accessible for easier service.
GREEN REFRIGERANT R-410A
PA13-SERIES PACKAGED AIR CONDITIONERS
Cooling Capacities: 23,000 to 56,000
SEER: 13.0
Standard Engineered Features Field Installed Accessories
Optional Field Installed Electric Heat
Strips:
With automatic limit and thermal cutoff.
• Field installed heater package for all
models.
• Features slide-in field assembly with
various BTUH outputs.
• Permits stocking of only one unit.
Optional Field Installed Low Ambient
Control:
Cycles outdoor fan motor below 55°F
outdoor temperature to maintain acceptable
condensing pressure.
• Intertek ETL Listed to Standard for Safety Heating
and Cooling Equipment ANSI/UL 1995/CSA 22.2
No. 236-05, Third Edition.
FRONT (INDOOR AIRFLOW) END OF UNIT
BACK (OUTDOOR AIRFLOW) END OF UNIT

Form No. S3383-1112
Supersedes S3383-510
Page 2 of 8
Tested and Certified in accordance with ARI Standard 210/240-2003.
Cooling Capacities and Efficiency Ratings
General Specifications
Indoor Blower Performance 1
SLEDOM esahP HUTB REES
A-24231AP1000,3200.31
A-20331AP1000,9200.31
B-,A-26331AP3dna1000,4300.31
C-,B-,A-22431AP3dna1000,3405.31
C-,B-,A-28431AP3dna1005,6400.31
C-,B-,A-20631AP3dna1000,6500.31
ledoM A-24231AP A-20331AP A-26331AP B-26331AP A-22431AP B-22431AP C-22431AP A-28431AP B-28431AP C-28431AP A-20631AP B-20631AP C-20631AP
–gnitaRcirtcelE AtiucriC–zH06
1-06-802/0321-06-802/0321-06-802/0323-06-802/0321-06-802/0323-06-802/0323-06-0641-06-802/0323-06-802/0323-06-0641-06-802/0323-06-802/0323-06-064
egnaRegatloVgnitarepO352-791352-791352-791352-781352-791352-781605-414352-791352-781605-414352-791352-781605-414
yticapmAtiucriCmuminiM 451814261333221339241936271
CSCB9
115101125182241862619
eziSeriWdleiF 321018210101418012180101
eziSeriWdnuorG21018210101418014180121
.xaM–esuFyaleD 202525302055351050402060452
802/032–spmAtinulatoT8.11/8.018.41/3.314.81/4.613.31/0.711.81/2.614.51/1.414.017.42/0.320.81/9.617.019.82/3.529.91/7.719.11
AtiucriC–rosserpmoC
epyTrosserpmoC.piceR.piceR.piceR.piceRllorcSllorcSllorcSllorcSllorcSllorcSllorcSllorcSllorcS
stloV802/032802/032802/032802/032802/032802/032064802/032802/032064802/032802/032064
spmAdaoLdetaR5.8/5.711/5.941/219.8/6.77.31/8.116.9/3.87.77.81/7121/9.017.79.22/3.919.31/7.116.8
spmArotoRkcoL84/8475/7547/4757/57511/511511/51105711/7111.38/1.3805431/431011/01125
dnarotoMnaF resnednoC
PH–rotoMnaF528-6/1528-6/1528-6/1528-6/1528-4/1528-4/1528-4/1528-4/1528-4/1528-4/1528-4/1528-4/1528-4/1
spmArotoMnaF1.11.11.11.15.15.15.15.15.15.15.15.15.1
MFC/.aiD–naF0072/"420062/"420062/"420062/"420043/"420043/"420043/"420043/"420043/"420043/"420043/"420043/"420043/"42
rotaropavEdnarotoM
PH–rotoMrewolB 1MCE-3/1MCE-2/1MCE-2/1MCE-2/1MCE-2/1MCE-2/1MCE-2/1MCE-4/3MCE-4/3MCE-4/3MCE-4/3MCE-4/3MCE-4/3
spmA–rotoMrewolB2.27.23.33.39.39.39.35.45.45.40.50.50.5
).zo014-R(egrahC5758021021061061061061061061061061061
)sdnuop(thgieWgnippihS063014014014044044094044044094054054005
LEDOM detaR PSE XAM PSE
2
suounitnoC wolfriA
3
detaR gnilooC MFC
4
detaR taeHcirtcelE MFC
4231AP01.005.00060080001
0331AP51.005.005700010001
6331AP51.005.052800110011
2431AP02.005.052900410041
8431AP02.005.0520105510571
0631AP02.005.0051105710571
1Motor will deliver consistent CFM through voltage supply range with no deterioration (197-253V for all 230/208V models).
2Continuous CFM is the total air being circulated during continuous (manual fan) mode.
3Will occur automatically with a call for “Y” for cooling mode operation.
4Will occur automatically with a call for “W1” for heating mode operation.
1ECM = Electronically Commutated Motor
2Maximum time delay fuse or HACR type circuit breaker for protection of field wiring devices.
3Based on
75°C
copper wire. All wiring must conform to the National Electrical Code and all local codes.
4These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to National Electric Code (latest revision), Article 310 for power
conductor sizing.

Form No. S3383-1112
Supersedes S3383-510
Page 3 of 8
Optional Field Installed Heater Packages Are Only To Be Used With The Models
As Indicated Below
Optional Field Installed Electric Heater Packages
Optional field-installed electric heater packages are available for 5 through 15Kw
capacities. The heater packages are UL listed to be field-installed into the basic unit.
They feature prewired control circuit wiring with plug-in connector. Simply slide the
heater into the unit, plug in the pretested control circuit and connect the separate high
voltage circuit wiring.
IMPORTANT: While this electrical data is presented as a guide, it is important to
electrically connect properly sized fuses and conductor wires in accordance with the
National Electrical Code and all existing local codes.
retaeH egakcaP ledoM &stloV esahP A-24231APA-20331APA-26331APB-26331APA-22431APB-22431APC-22431APA-28431APB-28431APC-28431APA-20631APB-20631APC-20631AP
50A-323PHE1-802/042 XXX
01A-323PHE1-802/042 XXX
51A-323PHE1-802/042XX
90B-323PHE3-802/042X
51B-323PHE3-802/042X
50A-315PHE1-802/042 XXX
01A-315PHE1-802/042 XXX
51A-315PHE1-802/042 XXX
90B-315PHE3-802/042 XXX
51B-315PHE3-802/042 XXX
90C-315PHE3-064 XXX
51C-315PHE3-064 XXX
Optional Field Installed Electric Heater Table — 2 through 5 Ton
retaeH egakcaP .oNledoM
tinU stloV sesahP
yticapaC&WK.rtH )084(stloV042@ yticapaC&WK.rtH stloV802@ V802/042 .rtH spmA )084(
retaeH lanretnI tiucriC rekaerB
BtiucriC
WKHUTBWKHUTB .oN dleiF stiucriC
3
.niM tiucriC yticapmA
1
revO.xaM tnerruC noitcetorP
2
dleiF rewoP gniriW
2
dnuorG eriW eziS
50A-323PHE1-802/0425
001,7157.3008,211.81/8.02
06/03
132/6252/0301/0101
01A-323PHE1-802/04201001,4305.7000,622.63/6.141
64/3505/068/601
51A-323PHE1-802/04251002,1552.11004,831.45/5.26186/9707/084/48
50A-315PHE1-802/0425
001,7157.3008,211.81/8.02
06/03
132/6252/0301/0101
01A-315PHE1-802/04201001,4305.7000,622.63/6.141
64/3505/068/601
51A-315PHE1-802/04251002,1552.11004,831.45/5.26186/9707/084/48
90B-323PHE3-802/0429007,0357.6000,327.81/7.12 enoN 142/8252/0301/0101
51B-323PHE3-802/04251002,1552.11004,832.13/2.631
93/6404/058/801
90B-315PHE3-802/0429007,0357.6000,327.81/7.12 enoN 142/8252/0301/0101
51B-315PHE3-802/04251002,1552.11004,832.13/2.631
93/6404/058/801
90C-315PHE3-0849 007,038.01 enoN 141514141
51C-315PHE3-08451002,15811
82030121
IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor
wires in accordance with the National Electrical Code and all existing local codes.
1Maximum size of the time delay fuse or HACR circuit breaker for protection of field wiring devices.
2Based on wire suitable for 75°C. Other wiring materials must be rated for marked “Minimum Circuit Ampacity” or greater. Based on 75°C copper wire. All wiring
must conform to the National Electric Code and all local codes.
3These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National Electric Code (latest revision), Article 310 for
power conductor sizing.

Form No. S3383-1112
Supersedes S3383-510
Page 4 of 8
1Below 55°F, unit requires a field installed low ambient control model CMA-28.
2Return air temperature °F.
Cooling Application Data — Outdoor Temperature 1
ledoM .B.W/.B.D 22
2
22
gnilooC yticapaC F°erutarepmeTroodtuO
F°55 F°06 F°56 F°07 F°57 F°08 F°58 F°09 F°59 F°001 F°501 F°011 F°511 F°021
4231AP
26/57 gnilooClatoT gnilooCelbisneS 001,03 006,02 000,92 001,02 009,72 007,91 057,62 052,91 056,52 008,81 055,42 004,81 005,32 059,71 004,22 005,71 003,12 001,71 001,02 056,61 058,81 002,61 056,71 057,51 054,61 052,51 002,51 008,41
76/08 gnilooClatoT gnilooCelbisneS 009,13 057,02 057,03 052,02 056,92 008,91 005,82 003,91 004,72 008,81 003,62 003,81 002,52 057,71 001,42 052,71 000,32 007,61 008,12 053,61 006,02 000,51 004,91 007,51 002,81 053,51 000,71 000,51
27/58 gnilooClatoT gnilooCelbisneS 006,53 009,02 053,43 054,02 051,33 059,91 059,13 005,91 057,03 000,91 006,92 005,81 054,82 000,81 003,72 005,71 051,62 059,61 056,42 006,61 002,32 003,61 057,12 059,51 052,02 006,51 008,81 052,51
0331AP
26/57 gnilooClatoT gnilooCelbisneS 051,83 050,72 007,63 054,62 003,53 058,52 009,33 052,52 005,23 006,42 001,13 050,42 007,92 054,32 003,82 009,22 058,62 003,22 054,52 006,12 000,42 058,02 055,22 051,02 001,12 004,91 007,91 007,81
76/08 gnilooClatoT gnilooCelbisneS 004,04 003,72 059,83 056,62 055,73 059,52 001,63 003,52 007,43 006,42 003,33 009,32 058,13 002,32 054,03 005,22 000,92 008,12 006,72 002,12 002,62 056,02 008,42 050,02 004,32 005,91 000,22 009,81
27/58 gnilooClatoT gnilooCelbisneS 050,54 005,72 055,34 058,62 000,24 002,62 054,04 055,52 009,83 058,42 004,73 002,42 059,53 005,32 054,43 008,22 059,23 051,22 002,13 055,12 005,92 059,02 057,72 004,02 050,62 008,91 003,42 002,91
6331AP
26/57 gnilooClatoT gnilooCelbisneS 002,34 051,84 007,14 054,54 002,04 008,24 007,83 001,04 051,73 054,73 057,53 053,43 053,43 052,13 009,23 051,82 005,13 050,52 006,92 050,42 057,72 000,32 058,52 059,12 059,32 009,02 001,22 058,91
76/08 gnilooClatoT gnilooCelbisneS 057,54 004,84 052,44 056,54 007,24 009,24 002,14 051,04 007,93 004,73 003,83 002,43 058,63 059,03 054,53 057,72 000,43 005,42 051,23 006,32 003,03 057,22 004,82 058,12 055,62 000,12 007,42 001,02
27/58 gnilooClatoT gnilooCelbisneS 050,15 058,84 004,94 001,64 008,74 053,34 051,64 055,04 005,44 008,73 050,34 006,43 055,14 053,13 001,04 001,82 006,83 009,42 053,63 000,42 001,43 001,32 058,13 002,22 055,92 003,12 003,72 004,02
2431AP
26/57 gnilooClatoT gnilooCelbisneS 052,45 005,93 054,25 007,83 056,05 059,73 009,84 051,73 001,74 004,63 003,54 056,53 054,34 059,43 056,14 052,43 058,93 055,33 051,83 005,23 054,63 004,13 057,43 003,03 001,33 052,92 004,13 051,82
76/08 gnilooClatoT gnilooCelbisneS 004,75 009,93 056,55 000,93 058,35 001,83 001,25 052,73 003,05 053,63 005,84 054,53 056,64 006,43 058,44 007,33 000,34 008,23 004,14 059,13 058,93 001,13 052,83 002,03 007,63 053,92 001,53 005,82
27/58 gnilooClatoT gnilooCelbisneS 050,46 002,04 051,26 053,93 052,06 054,83 003,85 006,73 004,65 057,63 005,45 009,53 056,25 050,53 057,05 051,43 058,84 003,33 058,64 054,23 058,44 055,13 058,24 007,03 008,04 008,92 008,83 059,82
8431AP
26/57 gnilooClatoT gnilooCelbisneS 055,75 002,24 007,55 003,14 009,35 004,04 050,25 005,93 052,05 006,83 254,84 007,73 056,64 058,63 058,44 059,53 001,34 001,53 001,14 050,43 001,93 050,33 051,73 000,23 051,53 059,03 002,33 059,92
76/08 gnilooClatoT gnilooCelbisneS 058,06 006,24 050,95 006,14 052,75 055,04 054,55 055,93 056,35 055,83 058,15 005,73 001,05 054,63 003,84 053,53 005,64 003,43 006,44 005,33 057,24 007,23 058,04 009,13 000,93 001,13 001,73 003,03
27/58 gnilooClatoT gnilooCelbisneS 009,76 059,24 000,66 059,14 050,46 059,04 001,26 059,93 051,06 059,83 053,85 059,73 005,65 009,63 056,45 058,53 008,25 058,43 054,05 620,43 001,84 002,33 057,54 004,23 004,34 006,13 000,14 008,03
0631AP
26/57 gnilooClatoT gnilooCelbisneS 004,66 059,64 055,46 052,64 007,26 055,54 009,06 058,44 050,95 002,44 053,75 058,34 007,55 055,34 000,45 052,34 053,25 009,24 008,94 057,04 003,74 055,83 057,44 053,63 052,24 002,43 007,93 000,23
76/08 gnilooClatoT gnilooCelbisneS 052,07 054,74 054,86 006,64 056,66 008,54 058,46 059,44 050,36 051,44 004,16 006,34 008,95 050,34 051,85 005,24 000,65 059,14 001,45 050,04 056,15 051,83 052,94 002,63 008,64 003,43 004,44 004,23
27/58 gnilooClatoT gnilooCelbisneS 053,87 008,74 054,67 000,74 005,47 002,64 006,27 054,54 007,07 056,44 050,96 001,44 054,76 006,34 008,56 001,34 002,46 006,24 002,16 056,04 051,85 007,83 051,55 008,63 001,25 058,43 001,94 009,23

Form No. S3383-1112
Supersedes S3383-510
Page 5 of 8
36" min.
24" min.
24" min.
The distance between
1 inch clearance
Access
Air Inlet
Comp-
Nearest Structure
Air Inlet
Supply and Return Ducts
Nearest Structure
Nearest Structure
Building
Control Panel
Access
Control Panel
Access
Heater Package Access
Blower Service
and
ressor
Blower Motor
Heater Package
Blower
Compressor
from top.
units only).
Condenser fan
and motor access
above fan.
Leave 60" min.
Side
View
View
Top
between duct and
any combustible
material if distance
between outside
wall and unit is less
than 3 feet (needed
on electric heat
MIS-2143 A
Mounting Slab
Ground Level
Package Unit
Supply Duct
from building
Return Duct
requirements.
outside wall and unit
Air Outlet
varies with installation
1/4 inch per foot
slope away
Building
Both legs must rest
on surface of platform
32°F or lower climate
12" min. if in
48" min.
48" min.
32°F or lower climate
12" min. if in
on surface of platform
Both legs must rest
Platform can be as
shown or solid
Poured concrete,
brick, or block
Metal frame
MIS-2144 A
Airflow & Service Access Clearances
Slab Mounting at Ground Level
Elevated Mounting Platforms (Field Constructed)

Form No. S3383-1112
Supersedes S3383-510
Page 6 of 8
Unit Dimensions
Return opening
Drain access
Supply opening
High voltage knockout
Low voltage knockout
access door
Control panel door
Heater package access panel
Compressor
Heater package knockout
A
E
C
D
L
W
B
F
Condenser air
Condenser air
intake grille
intake grille
access door
Blower motor
Condenser fan
G
47 11/16"
H
Unit Dimension Chart
MIS-2142 A
A C B C H (height) L (length) W (width) D E F G
PA/PH1324,1330,1336 5.875 32.875 13.875 32.875 26.25 53.25 38.125 23.25 1.125 1.375 35.625
PA/PH1342,1348,1360 9.875 37.875 15.875 37.875 33.25 55.25 42.375 30.25 1.5 2.375 38.125
Unit
Unit General Dimensions
Supply Size Return Size Unit Overall Dimensions
traPdellatsnIdleiF oTelbacilppA noitpircseD
82-AMCsledoMllAlortnoCtneibmAwoL
51-CMCsledoMA-llAtiKtratSrosserpmoC
Optional Control Modules — Field Installed

Form No. S3383-1112
Supersedes S3383-510
Page 7 of 8
Optional Equipment — Roof Hood
• Built-in filter
• Fresh air damper assembly provides up to 15% outside air.
• Requires prefabricated roof curb 9042-003 or 9042-004.
Order separately.
• Shipped knocked down
• Polyester baked enamel galvanneal cabinet
• Heavy insulation - 1/2 inch
.oNledo
M
oTelbacilppAthgieWgnippihS
A-313PH
R
sledomnot3dna2/1-2,2011
A-315PH
R
sledomnot5dna4,2/1-3021
gnippihS-stinutnelaviuqE†
Performance and Application Data — RHP
riAylppuS citatS)MFC(riAnoitalitneV
00.0A/NA/N331381622062382092403023073
02.0A/NA/N331381622062382092403A/NA/N
04.0A/NA/N33138162.2062382092A/NA/NA/N
citatSnruteR00.050.001.051.002.052.003.053.004.054.0
0
5.0
riAylppuS citatS )MFC(riAnoitalitneV
00.0A/NA/N08561512052082013043073004
02.0A/NA/N08561512052082013043073004
04.0A/NA/N08561512052082013043073004
citatSnruteR00.050.001.051.002.052.003.053.004.054.0
0
5.0
Unit Dimensions
dooHfooR ledoM ledoM lanimoN egannoT A C D "1 retliF
A-313PHR 4231HP/4231AP 0331HP/0331AP 6331HP/6331AP
noT2 noT½2 noT3 8/1-83624/1-35 61x61)1( dna 02x61)1(
A-315PHR 2431HP/2431AP 8431HP/8431AP 0631HP/0631AP
noT½3 noT4 noT5 24334/1-5502x61)2(
Heavy gauge galvanized with wood nailing strip, welded/leakproof one piece
construction - ready to install.
ledoM
htiWdesU dooHfooR ledoM A B C 1D E F J 1H1
dnapmuPtaeH stinUgninoitidnoCriA
300-2409 )bruC63P( A-313PHR8/3-084/1-044/1-738/3-838/3-53244/3-418/1-91sledoMnoT3&,2/1-2,2llA
400-2409 )bruC06P( A-315PHR8/3-288/1-448/1-148/3-838/3-53444/3-418/1-91sledoMnoT5&4,2/1-3llA
.oNledo
M
oTelbacilppA†.U.EthgieWgnippihS
300-240
9
sledomnot3dna2/1-2,208.441
400-240
9
sledomnot5dna4,2/1-308.061
gnippihS-stinutnelaviuqE†
• Heavy gauge galvanized with wood nailing strip.
• Prefabricated roof curb requires roof hood RHP313-A & RHP513-A.
Order separately.
Optional Equipment — Pre-Fabricated Roof Curb
1Duct Sizing Information:
Return air dimension “C” is length / Supply air dimension “C” is length.
Return air dimension “H” is width / Supply air dimension “J” is width.
RHP313-A Ventilation Air RHP513-A BFAD Ventilation Air
JH
1 1/2"
MIS-2254
X A WIDTH
AIR CONDITIONING UNIT
RETURN AIR SUPPLY AIR
FILTER
FRESH AIR
OPENING
ROOF HOOD
38 1/4
D
C
12 1/2"

Form No. S3383-1112
Supersedes S3383-510
Page 8 of 8
Optional Equipment — Energy Recovery Ventilator
• Assures continuous supply of fresh air and reduction of all indoor air pollutants. IAQ ASHRAE 62.1
• Provides 250 to 400 CFM (adjustable) of outside air and exhaust. Efficiencies up to 77% heating and 65% cooling.
• Designed for easy installation on roof hoods RHP313-A and RHP513-A.
.oNledoM
t
hgieWgnippihS
)V802/032(X-D3A-RVRE.sbl521
)064(X-D3C-RVRE.sbl521
C3A-RVRE-ATADNOITACILPPADNAECNAMROFREP
ecnamrofrePgnilooCremmuS )BW°26/BD°57snoitidnoCngiseDroodnI(
tneibmA .D.O MFC004-ETARNOITALITNEV ycneiciffE%36 MFC523-ETARNOITALITNEV ycneiciffE%46 MFC052-ETARNOITALITNEV ycneiciffE%56
F°BW/B
D
TLV SLV LLV TRH SRH LRH TLV SLV LLV TRH SRH LRH TLV SLV LLV TRH SRH LRH
50
1
57080,91069,21021,6020,21461,8558,3205,51035,01279,4129,9937,6281,3529,11001,8528,3157,7562,5684,2
07069,21069,210461,8461,80 035,01035,010
937,6937,60001,8001,80562,5562,50
56069,21069,210461,8461,80 035,01035,010937,6937,60001,8001,80562,5562,50
00
1
08080,82008,01082,71096,71408,6688,01518,22577,8040,41106,41616,5589,8055,71057,6008,01704,11783,4910,7
57080,91008,01082,8020,21408,6612,5205,51577,8727,6129,9616,5503,4529,11057,6571,5157,7783,4363,3
07089,01008,01081719,6408,6311129,8577,8641907,5616,539268,6057,6211064,4783,437
56008,01008,010408,6408,60 577,8577,80 616,5616,50 057,6057,60 783,4783,40
06008,01008,010408,6408,60 577,8577,80 616,5616,50 057,6057,60 783,4783,40
5
9
08080,82046,8044,91096,71344,5742,21518,22020,7597,51106,41294,4801,01055,71004,5051,21704,11015,3798,7
57080,91046,8044,01020,21344,5775,6205,51020,7284,8129,9294,4824,5529,11004,5525,6157,7015,3142,4
07089,01046,8043,2719,6344,5474,1129,8020,7109,1907,5294,4612,1268,6004,5264,1064,4015,3059
56046,8046,80 344,5344,50 020,7020,70 294,4294,40 004,5004,50 015,3015,30
06046,8046,80 344,5344,50 020,7020,70 294,4294,40 004,5004,50 015,3015,30
0
9
08080,82084,6006,12096,71280,4806,31518,22562,5055,71106,41963,3232,11055,71050,4005,31704,11236,2477,8
57080,91084,6006,21020,21280,4839,7205,51562,5732,01129,9963,3255,6529,11050,4578,7157,7236,2811,5
07089,01084,6005,4719,6280,4538,2129,8562,5656,3907,5963,3043,2268,6050,4218,2064,4236,2828,1
56084,6084,60 280,4280,40 562,5562,50 963,3963,30 050,4050,40 236,2236,20
06084,6084,60 280,4280,40 562,5562,50 963,3963,30 050,4050,40 236,2236,20
5
8
08080,82023,4067,32096,71127,2869,41518,22015,3503,91106,41642,2553,21055,71007,2058,41704,11557,1256,9
57080,91023,4067,41020,21127,2892,9205,51015,3299,11129,9642,2576,7529,11007,2522,9157,7557,1699,5
07089,01023,4066,6719,6127,2591,4129,8015,3114,5907,5642,2364,3268,6007,2261,4064,4557,1507,2
56023,4023,40 127,2127,20 015,3015,30 642,2642,20 007,2007,20 557,1557,10
06023,4023,40 127,2127,20 015,3015,30 642,2642,20 007,2007,20 557,1557,10
0
8
57080,91061,2029,61020,21063,1956,01205,51557,1747,31129,9321,1897,8529,11053,1575,01157,7778378,6
07089,01061,2028,8719,6063,1655,5129,8557,1661,7907,5321,1685,4268,6053,1215,5064,4778385,3
56087,3061,2026,1183,2063,1020,1170,3557,1613,1569,1321,1248263,2053,1210,1535,1778856
06061,2061,20 063,1063,10 557,1557,10321,1321,10 053,1053,107787780
5
7
07089,010089,01719,60 719,6129,80 129,8907,50907,5268,60 268,6064,40064,4
56087,30 087,3183,20 183,2170,30 170,3569,10569,1263,20 263,2535,10535,1
06
000000000000000000
ecnamrofrePgnitaeHretniW )BDF°07snoitidnoCngiseDroodnI(
tneibmA .D.O ETARNOITALITNEV
ycneiciffE%57MFC004 ycneiciffE%67MFC523
y
cneiciffE%77MFC052
F°BD LVW RHW LVW RHW LVW RHW
56061,2026,1557,1333,1053,1930,1
06023,4042,3015,3766,2007,2970,2
55084,6068,4562,5100,4050,4811,3
05046,8084,6020,7533,5004,5851,4
54008,01001,8577,8966,6057,6791,5
04069,21027,9035,01200,8001,8732,6
53021,51043,11582,21633,9054,9672,7
03082,71069,21040,41076,01008,01613,8
52044,91085,41597,51400,21051,21553,9
02006,12002,61055,71833,31005,31593,01
51067,32028,71503,91176,41058,41434,11
SNOISNEMIDTINU
ledoM htdiW htpeD thgieH thgieWgnippihS
RVRE4/3-23*4/3-814/3-81.sbl521
* Does not include 1" mounting brackets on each side of ERVR.
ROOF HOOD
SUPPLY DUCTRETURN DUCT
ROOF
PACKAGE UNIT
ROOF CURB
MIS-2253
Bard Manufacturing Company, Inc.
Bryan, Ohio 43506
www.bardhvac.com
Due to our continuous product improvement
policy, all specifications subject to change
without notice.
Before purchasing this appliance, read important energy
cost and efficiency information available from your retailer.
Form No.
S3383
November, 2012
Supersedes: S3383-510
Legend:
VLT = Ventilation Load - Total
VLS = Ventilation Load - Sensible
VLL = Ventilation Load - Latent
HRT = Heat Recovery - Total
HRS = Heat Recovery - Sensible
HRL = Heat Recovery - Latent
WVL = Winter Ventilation Load
WHR = Winter Heat Recovery
This manual suits for next models
13
Table of contents
Other Bard Air Conditioner manuals

Bard
Bard 11EER WA W18AB-A User guide

Bard
Bard H42A1 User manual

Bard
Bard WA4822 User manual

Bard
Bard WG3S1 User manual

Bard
Bard HAC181-AD040 User manual

Bard
Bard WA423 User manual

Bard
Bard FUSION-TEC HR36APA Operating instructions

Bard
Bard P1124A3 User manual

Bard
Bard Wall-Mount CT Series User manual

Bard
Bard WL421 User manual
Popular Air Conditioner manuals by other brands

Lloyd
Lloyd LS18HC user manual

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries DXK05ZTLA-WF user manual

Be Cool
Be Cool BCP5AC2101F manual

Mitsubishi Electric
Mitsubishi Electric MSZ-GE25VA operating instructions

Sears
Sears Kenmore P/N93SR-D02 owner's manual

Bryant
Bryant Evolution Extreme 186CNV installation instructions