TL205
INSTALLATION INSTRUCTIONS
800 533.3948 •www.barronltg.com
2
20070044 REV 2 - 12/13
OPTICAL ASSEMBLY INSTALLATION
1. Remove a minimum of 3 screws from the reflector mounting
neck.
2. Orient reflector so the aiming sight is pointed up and the hinge
is pointed down.
3. Push reflector against the mounting neck so the one remaining
screw head pass thru the keyhole slot.
4. Rotate reflector so the screw head is in the narrow
end of the keyhole slot. Install remaining (3) screws and tighten
to secure reflector.
5. Loosen the (2) Phillips hinge safety screws located on the
reflector to allow the installation of the lens frame hinge “T”.
6. Close the lens frame assembly against the reflector, make sure
the gasket is seated properly and snap the latches
over the lid of the reflector to secure the lens assembly.
7.Tighten hinge safety screws.
CARE AND MAINTENANCE
For optimum performance periodically clean reflector and lens with a soft, damp rag. DO NOT use abrasive materials,
glass cleaner or other solvents on lens or paint. Use only non-abrasive glass cleaner, mild soapy water and rinse with
clean water.
TROUBLESHOOTING CHECKLIST
1. Check your power source.
2. If power is on and lamp does not burn. Turn power source off. Lock out to prevent power being restored.
3. Check electrical connections.
4. Check to insure proper seating of lamp.
5. Restore power.
6. Check if lamp is burned out.
REPLACING LAMP INSTRUCTIONS
1. When re-lamping, turn power off and allow the fixture to cool.
2. Prior to installing the lamp in the fixture, check the lamp is of proper type and wattage.
3. Screw the lamp into the socket, back the lamp out slightly then screw the lamp securely back in to make sure it is
properly seated in the socket.
4. Close the diffuser and secure with screws. Be sure that the gasket is firmly seated in the proper channel prior to
closing fixture to maintain weather-tight seal.
Note: Replace only with a lamp of same type and wattage as indicated on the fixture product label.