Installation Manual
SENTIDO RS485
© 2020
basalte v3.0
basalte bv | hundelgemsesteenweg 1A | 9820 merelbeke | belgium
t +32 (0)9 385 78 38 | f +32 (0)9 329 66 95 | www.basalte.be | info@basalte.be
Technical data
Current consumption: 0.5 W
Ambient temperature:
Operation: -5°C to 45°C
Storage: -15°C to 55°C
Transport: -15°C to 55°C
Max. humidity: 93% relative humidity,
no moisture condensation
Protection class: II
Type of protection: IP 20
Certification: CE
Installation and commissioning
• Use a standard European backbox with screws. The distance between the screws needs to be 60mm. The
depth required is 24mm, however additional depth should be reserved for connecting the device.
• Mount Sentido with the temperature sensor upwards.
• Use screws with a countersunk, flat head and do not apply too much force as this might deform the plastic
housing.
• Connect the 4 colored strands to the RS485 bus cable in accordance to standard RS485 guidelines.
• (Red = 24, White = Y, Blue = Z, Black = G) A maximum of 32 devices can be connected on one bus cable.
• Configure the hexadecimal address of the Sentido RS485 using the Serial.link configuration tool.
• Caution: Address 00 cannot be used, so only addresses from 01 to FF are valid.
• When using the dual Sentido front cover, disable sensor 2 and 3. Only sensor 1 and 4 will be used.
• After a bus voltage failure or bus reset, Sentido will not be ready for operation for at least 5 seconds.
Note
Please refer to the appropriate application notes to configure the Sentido RS485 keypad on Lutron or Crestron.
How to mount the Sentido front cover (not included)
Only install the Sentido front cover while the switch is not powered.
Push the Sentido front cover firmly onto the Sentido switch. The front cover is fixed to the switch by the clipsing
system.
Make sure the cover is mounted using all 4 clips.
Power the device once the front cover is mounted. Calibration will be initiated.
Calibration
In order to function properly, the sensors of the Sentido RS485 need to calibrate to the environment. This
calibration starts when bus power is applied, when a cover is installed or can be forced when the sensors detect a
touch for more than 20 seconds.
During calibration, the RGB led will light up blue and slowly fade up and down. Make sure not to touch the cover
when the calibration process is ongoing! At the end of calibration, the RGB led will blink green. The switch is now
ready to be used.
How to remove the Sentido front cover
We provide the ‘tube’ tool to easily remove the Sentido front cover.
Do not use a screwdriver or other tools, as these might damage the cover.