BAT DZ 20-A V2 User manual

TIMER SWITCH
Operation and Safety Notes
I
DŐZÍTŐ KAPCSOLÓ
Kezelési és biztonsági utalások
ZEITSCHALTUHR
Bedienungs- und Sicherheitshinweise
KOPPLINGSUR
Bruksanvisning och
säkerhetsanvisningar
TIJDSCHAKELKLOK
Bedienings- en veiligheidsinstructies
RELOJ TEMPORIZADOR
Instrucciones de utilización y de seguridad
ΧΡΟΝΟΔΙΑΚΟΠΤΗΣ
Υποδείξεις χειρισμού και ασφαλείας
DZ 20-A V2
DZ 20-A V2_Zeitschaltuhren_digital_cover_DE_GB_NL_SE_ES_HU_GR.indd 204.07.16 11:03

33GB
Introduction.................................... Page 37
Intended use ......................................... Page 37
Control elements................................... Page 38
Technical Data...................................... Page 39
Safety notices ............................... Page 40
Control- and display
elements............................................ Page 42
Control elements................................... Page 42
Displays + Explanation ........................ Page 42
Operating mode function..................... Page 44
Program function................................... Page 45
Clock function....................................... Page 45
Preparation .................................... Page 45
Charging the device............................. Page 46
Reset all settings.................................... Page 46
Setting the current time......................... Page 47
Setting standard and summer time...... Page 48
Setting the hour mode.......................... Page 49
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 3304.07.16 11:03

34 GB
Operation......................................... Page 50
Switching to the clock function ............ Page 50
(De) activating continuous operatio
n.... Page 51
Configuring programs.......................... Page 52
Switching the random function
on and off ............................................. Page 56
Cleaning............................................. Page 58
Disposal.............................................. Page 59
Manufacturer................................ Page 59
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 3404.07.16 11:03

35GB
B14
15
16
1718192021
22
23
24 13
A1
2
4
3
5
6
12
10
9
8
7
11
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 3504.07.16 11:03

36 GB
List of pictograms used:
Observe the warning and
safety instructions!
Attention! Risk of electric shock!
Do not dispose of electric equip-
ment in the household waste!
Use indoors
-10T40 Ambient temperature
Micro-switch with a contact
opening width of < 3mm
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 3604.07.16 11:03

37GB
Timer Switch
Digital – for indoors
Introduction
Intended use
The device is intended as a digital weekly
timer switch for use in enclosed, dry rooms
and designed for private use. It is not suita-
ble for commercial use. Only operate the
device individually. Do not connect several
timer switches in series. Any other use is con-
sidered improper. The manufacturer is not
liable for damages due to improper use.
Read the entire instructions for use before
using the device. Keep these instructions for
use. Include the instructions for use when
passing the device on.
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 3704.07.16 11:03

38 GB
Control elements (Fig. A)
1LCD display
2MINUTE button
3RST/RCL button
4RANDOM button
5ON/AUTO/OFF button
6Socket
7Plug (reverse)
8Timer button
9CLOCK button
10 WEEK button
11 MASTERCLEAR button
12 HOUR button
LCD display (Fig. B)
13 Weekday display
14 R symbol
15 S symbol
16 Seconds display
17 ON – AUTO – OFF
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 3804.07.16 11:03

39GB
18 Minutes display
19 PROGRAM
20 Hours display
21 CLOCK
22 Program number
23 AM – PM
24 ON – OFF
Technical Data
Model designation: DZ 20-A V2
Operating voltage: 230–240V~50Hz
Switched voltage: 230–240V~
16(2) A
Switching capacity: max. 3600 W
Ambient temperature: -10°C to 40°C
-10T40
Time error: ± 1 minute/month
Shorting switching time: 1 minute
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 3904.07.16 11:03

40 GB
Programs: 10 ON/OFF
program sets
Battery: NiMH 1.2V
> 100h
Use
indoors:
EU compliant:
Safety notices
Children are not able to understand the
dangers arising from improper use of
electric devices. Never leave children
unsupervised when using electric devices.
Only plug the device into safely installed
sockets.
Only connect loads within the specified
capacities of the device.
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 4004.07.16 11:03

41GB
Do not cover the device. Heat accumu-
lates when covered, creating a fire
hazard.
Regularly check the device for damage.
Do not replace damaged parts but con-
tact the manufacturer or dispose of the de-
vice in an environmentally responsible wa
y.
Do not open the device. Opening the
device will void the warranty.
The device contains a rechargeable bat-
tery. A defective rechargeable battery
must be replaced by the manufacturer.
Do not touch the device with wet hands
or bring into contact with water.
Disconnect the device from the power
mains to de-energise.
Do not connect heaters or similar loads
to the device, as these must never be
operated unattended.
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 4104.07.16 11:03

42 GB
Control- and
display elements
Control elements
MASTERCLEAR button 11
This button will delete all time and program
settings.
Displays + Explanation
Weekdays 13
The abbreviations on the LCD display
1
mean:
MO Monday
TU Tuesday
WE Wednesday
TH Thursday
FR Friday
SA Saturday
SU Sunday
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 4204.07.16 11:03

43GB
R Symbol 14
The R symbol indicates random switching is
activated. The R symbol means random. In
this mode the device will switch the con-
nected loads on and off at different intervals.
S symbol 15
Indicates the clock has been set to summer
time.
ON – AUTO – OFF 17
Indicates the operating mode of the device.
PROGRAM 19
Indicates the program function has been
activated.
CLOCK 21
Indicates the clock function has been
activated.
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 4304.07.16 11:03

44 GB
Program number 22
Indicates the program number in PROGRAM
function.
AM – PM 23
Indicates the hour mode.
ON – OFF 24
Indicates the switching state:
ON = turn-on time, OFF = turn-off time.
The switching state is only visible under
program function.
Operating mode function
The different operating modes are:
AUTO = automatic program operation,
ON = continuous operation ON,
OFF = continuous operation OFF.
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 4404.07.16 11:03

45GB
Program function
This function allows the on- and off times to
be programmed for the connected load.
Clock function
This function shows the current time in the LCD.
Preparation
To start up the device you must:
1. Charge the device.
2. Reset all settings.
3. Set the current time.
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 4504.07.16 11:03

46 GB
Charging the device
Insert the plug 7into a mains socket.
Charge the rechargeable battery for
14 hours.
Reset all settings
Note: The device does not need to be con-
nected to the mains to configure the settings.
Reset all settings
Press the MASTERCLEAR 11 button with
a pen or other pointy object. The LCD
display 1will read:
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 4604.07.16 11:03

47GB
All settings cleared.
Setting the current time
Note: Hold the HOUR, MINUTE button for
faster programming.
Press and hold the CLOCK 21 button.
Set the current day of the week with the
WEEK 10 button.
Set the hour with the HOUR 12 button.
Set the minute with the MINUTE 2
button.
Release the CLOCK button 21 .
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 4704.07.16 11:03

48 GB
Setting standard
and summer time
Setting summer time
Simultaneously press the CLOCK 9
and ON/AUTO/OFF 5buttons. The
LCD 1will advance the hour display 20
by one hour and the S symbol 15 disap-
pears.
Setting standard time
Simultaneously press the CLOCK 9and
ON/AUTO/OFF 5buttons. The S
symbol 15 disappears from the LCD 1
and the hour 20 decreases by one.
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 4804.07.16 11:03

49GB
Setting the hour mode
The LCD 1can display the current time in
12- or 24-hour mode. In 12-hour mode AM
means before 12 noon, PM after 12 noon.
The default is 24 hour mode.
Setting to 12 hour mode
Simultaneously press the TIMER 8and
CLOCK 9buttons. The LCD will show
AM or PM 23 .
The following illustration shows
23:00 hours in 12-hour mode.
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 4904.07.16 11:03

50 GB
Setting to 24-hour mode
Simultaneously press the TIMER 8and
CLOCK 9buttons. The LCD will stop
showing AM or PM 23 .
Operation
Switching to the
clock function
The LCD 1automatically switches back to
clock function if a function is not used for
more than 30 seconds.
Press the CLOCK 9button to manually
go to the clock function.
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 5004.07.16 11:03

51GB
(De) activating
continuous operation
This device has the following operating modes:
– Continuous operation,
– Automatic program operation
The default is automatic program operation.
You can switch the device to continuous
operation separate from the programs.
Activating continuous operation
Repeatedly press the ON/ AUTO/
OFF 5button until the LCD 1reads
ON 17 .
DZ 20-A V2_Zeitschaltuhren_digital_content_DE_GB_NL_SE_ES_HU_GR.indd 5104.07.16 11:03
Other manuals for DZ 20-A V2
1
Table of contents