FHDH 14G6901/IO
11096625
Í?+)b9ÂÂ*ÂDÎ
1/2
IND. CONT. EQ
1DD2
Optoelektronische Sensoren
Photo electric sensors
Cellules opto-électroniques
Reflexions-Lichttaster mit
Hintergrundausblendung
Diffuse sensor with
background suppression
Détecteur réflex avec
élimination de l'arrière plan
Canada
Baumer Inc.
CA-Burlington, ON L7M 4B9
Phone +1 (1)905 335-8444
China
Baumer (China) Co., Ltd.
CN-201612 Shanghai
Phone +86 (0)21 6768 7095
Denmark
Baumer A/S
DK-8210 Aarhus V
Phone: +45 (0)8931 7611
France
Baumer SAS
FR-74250 Fillinges
Phone +33 (0)450 392 466
Germany
Baumer GmbH
DE-61169 Friedberg
Phone +49 (0)6031 60 07 0
India
Baumer India Private Limited
IN-411058 Pune
Phone +91 20 66292400
Italy
Baumer Italia S.r.l.
IT-20090 Assago, MI
Phone +39 (0)2 45 70 60 65
Singapore
Baumer (Singapore) Pte. Ltd.
SG-339412 Singapore
Phone +65 6396 4131
Sweden
Baumer A/S
SE-56133 Huskvarna
Phone +46 (0)36 13 94 30
Switzerland
Baumer Electric AG
CH-8501 Frauenfeld
Phone +41 (0)52 728 1313
United Kingdom
Baumer Ltd.
GB-Watchfield, Swindon, SN6 8TZ
Phone +44 (0)1793 783 839
USA
Baumer Ltd.
US-Southington, CT 06489
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Abmessungen Dimensions Dimensions
* 9,81
34,3
ø 71
96,8
52,240
19,6 REF
LED
• Alle Masse in mm
• All dimensions in mm
• Toutes les dimensions en mm
*Senderachse
*Emitter axis
*Axe de l'émetteur
Elektrischer Anschluss Connection diagram Schéma de raccordement
WH (2)
BU (3) 0 V
BN (1)
BK (4)
Z
Teach-in
Output/
IO-Link
+VS
Z
Push
Pull
BN = Braun/brown/brun
BK = Schwarz/black/noir
WH = Weiss/white/blanc
BU = Blau/blue/bleu
Siehe Betriebsanleitung auf www.baumer.com See manual on www.baumer.com Voir le manuel sur www.baumer.com
• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten.
• Disconnect power before connecting the sensor.
• Mettre l`installation hors tension avant le raccordement du détecteur.
Technische Daten Technical data Données techniques
Tastweite einstellbar Tw Sensing distance adjustable Tw Portée ajustable Tw
Tastbereich Tb bei Tw = 50 mm Sensiong distance Tb at Tw = 50 mm Plage de détection Tb à Tw = 50 mm
Tastbereich Tb bei Tw = 400 mm Sensiong distance Tb at Tw = 400 mm Plage de détection Tb à Tw = 400 mm
Betriebsspannungsbereich Vs (UL-Class 2) Voltage supply range Vs (UL-Class 2) Plage de tension Vs (UL-Class 2)
max. Stromverbrauch Mittel- / Spitzenwert max. supply current average / peak Consommation moyenne / pointe max.
max. Schaltstrom max. switching current Courant de sortie max.
Spannungsabfall Voltage drop Tension résiduelle
Ansprechzeit Response time Temps d'activation
Abfallzeit Release time Temps désactivation
Kurzschlussfest Short circuit protection Protégé contre courts-circuits
Verpolungsfest Reverse polarity protection Protégé contre inversion de polarité
Betriebstemperatur Temperature range Température de service
Schutzklasse Protection class Classe de protection
* nur Betriebsspannung / voltage supply only / plage de tension
20...50 mm
20...400 mm
10...30 VDC
35 mA / 40 mA
100 mA
2 VDC
≤ 1,8 ms
≤ 1,8 ms
ja/yes/oui
ja/yes/oui *
-30...+60 °C
IP68/IP69K
50...400 mm
Technische Änderungen vorbehalten Technical specifications subject to change Sous réserve de modifications techniques
2/2
Teach-in Abläufe
Teach-in procedures
Procédures de Teach-in
Externe Leitung: Teach-in der On-Position (1-Punkt Teach-in )
1. Sensor in Teach-in-Modus bringen: Teach-in Leitung (WH, Pin 2) >2
sek. und <5 sek mit +VS verbinden, bis die rote LED blinkt
2. Das Objekt in die gewünschte ON-Position bringen und Teach-in
Leitung kurz mit +VS verbinden
3. Wird die Teach-in Leitung noch einmal mit +Vs verbunden, wird der
Sensor auf Dunkelschaltung umgestellt, andernfalls nach einer kurzen
Wartezeit hellschaltend.
4. Leuchtet die rote LED für 2 sek. Ist der Teach-Vorgang abgeschlossen
- Wird der Sensor ausserhalb seines Erfassungsbereichs eingelernt, so
wird eine Warnung durch schnelles blinken der roten LED angezeigt.
Der Sensor wird auf maximale Tastweite eingestellt.
Externe Leitung: Teach-in der On- /Off-Position (2-Punkt Teach-in)
1. Sensor in Teach-in Modus bringen: Teach-in Leitung (WH, Pin 2) >5
sek. mit +VS verbinden, bis die rote LED blinkt
2. Das Objekt in die gewünschte ON-Position bringen und Teach-in
Leitung kurz mit +VS verbinden
3. Das Objekt in die gewünschte OFF-Position bringen und Teach-in
Leitung kurz mit +VS verbinden
4. Bei Tauschen der Punkte 2 und 3, wird der Sensor auf Dunkel-
schaltung umgestellt, andernfalls hellschaltend
- Wird der Sensor ausserhalb seines Erfassungsbereichs eingelernt
oder die Differenz der Lernpositionen ist zu klein für eine sichere
Anwendung, so wird eine Warnung durch schnelles blinken der roten
LED angezeigt. Der Sensor behält seine bisherigen Werte
Generell:
- Im Teachmodus wechselt der Ausgang auf 0V
- Im Normalbetrieb muss die Teach-in Leitung auf low gelegt werden
Teach-in externe: Teach-in de la position On (Teach-in à 1 point)
1. Amener le détecteur dans le mode Teach-in: relier le fil de connexion
Teach-in (WH, Pin 2) >2 sec et <5 sec avec Vs jusqu’à ce que la LED rouge
clignote.
2. Amener l’objet dans la position ON désirée et relier brièvement le fil de
connexion Teach-in avec +Vs.
3. Si le fil de connexion Teach-in est à nouveau relié avec Vs, le détecteur
passe en mode de commutation sombre sinon, après un court moment
d’attente, il reste en mode de commutation claire.
4. Si la LED rouge s’allume pendant 2 sec, le processus Teach-in est terminé
- Si l’apprentissage du détecteur se fait à l’extérieur de sa plage de détection,
une mise en garde est émise sous la forme d’un clignotement rapide de la
LED rouge. Le détecteur est réglé sur sa portée maximum.
Teach-in externe: Teach-in de la position On-Off (Teach-in 2 points)
1. Amener le détecteur dans le mode Teach-in: relier le fil de connexion
Teach-in (WH, Pin 2) >5 sec avec Vs jusqu’à ce que la LED rouge clignote.
2. Amener l’objet dans la position ON désirée et relier brièvement le fil de
connexion Teach-in avec +Vs.
3. Amener l’objet dans la position OFF désirée et relier brièvement le fil de
connexion Teach-in avec +Vs.
4. En inversant l’ordre 2 et 3, le détecteur est commuté sur commutation
sombre sinon il reste en commutation claire
- Si l’apprentissage du détecteur se fait à l’extérieur de sa plage de détection
ou si la différence des positions d’apprentissage est trop petite pour une
application fiable, une mise en garde est émise sous la forme d’un clignote-
ment rapide de la LED. Le détecteur conserve sa position d’apprentissage
valable auparavant.
Généralités:
- Lors du mode Teach-in, la sortie est commutée sur 0V
- Le fil de connection teach-in doit être raccordé à low en fonctionnement
normal
External cabling: Teach-in of the On position (single-point Teach-in)
1. Set the sensor to Teach-in mode: Connect the Teach-in cabling (WH,
pin 2) to +VS for >2 seconds and <5 seconds until the red LED blinks.
2. Bring the object into the desired On position and connect the Teach-in
cabling briefly to +VS.
3. If the Teach-in cabling is connected to +VS again, the sensor
is set to dark operate, otherwise it is set to light operate after a brief wait.
4. The Teach process is concluded when the red LED lights for 2 seconds.
- If the Teach-in procedures are run on the sensor outside its scanning
range, the red LED blinks quickly to indicate a warning. The sensor is
et to maximum sensing distance.
External cabling: Teach-in of the On/Off position (two-point Teach-in)
1. Bring the sensor into the Teach-in mode: Connect the Teach-in cabling
(WH, pin 2) to +VS for >5 seconds until the red LED blinks.
2. Bring the object into the desired On position and connect the Teach-in
cabling briefly to +VS.
3. Bring the object into the desired Off position and connect the Teach-in
cabling briefly to +VS.
4. The sensor is set to dark operate by interchanging the order of items
2 and 3, otherwise it is set to light operate.
- If the Teach-in procedures are run on the sensor outside its scanning
range or if the difference in the Teach-in positions is too small for reliable
application, the red LED blinks quickly to indicate a warning. The sensor
retains its previous values.
General:
- In Teach-in mode, the output switches to 0V
- The teach-in wire has to be connected with low in normal operation
Zubehör
Accessories
Accessoires
S= 1.5 ... 6.5 mm
13,8 s 7
1 x SW 24
2 x SW 24
24
SW
25,8
ø
17
ø
Befestigungskit HI17-1H
Mounting kit HI17-1H
Kit de montage HI17-1H
Art. No: 11039553
Hygienekonforme Montage
Hygienic compliant mounting
Montage hygiénique conforme
Baumer electric
Swissmade
Baumer electric
Swissmade
Baumer electric
Baumer electric
Reinigungshinweis: Während jedes Reinigungsvorgangs muss die im Datenblatt angegebene maximale Arbeitstemperatur berücksichtigt werden. Der Sensor darf mit einem
Wasserstrahl entsprechend der IP 69K Richtlinien gereinigt werden. Die im Sensor verwendeten Materialien sind höchst chemiebeständig gegen eine grosse Auswahl von
Säuren, Basen und Alkoholen. Es liegt in der Verantwortung des Benutzers, die chemische Resistenz des Sensors gegen die genutzten Reinigungsmittel vor der Reinigung zu
überprüfen. Weitere Informationen auf der Website des Herstellers: www.baumer.com
Important hints on applicable cleaning procedures: During any cleaning operation the maximum working temperature, as shown in the specification sheet, must be taken into
account. The sensor may be cleaned by applying a water jet as specified in the IP69K sealing guidelines. The sensor materials are highly chemically resistant against a wide
range of acids, bases and alcohols. It is the user’s responsibility to verify the chemical resistance of the sensor against the cleaning materials used prior to cleaning. For further
information please visit the product website at: www.baumer.com
Indication pour le nettoyage: Pendant chaque processus de nettoyage, il faut tenir compte de la température maximale de travail mentionnée sur la fiche technique. Le
détecteur peut être nettoyé au jet d’eau sous pression selon les directives IP 69K. Les matériaux utilisés lors de la fabrication du détecteur sont extrêmement résistant à un grand
nombre d’acides, de bases et d’alcools. Avant de procéder aux opérations de nettoyage, il appartient à l’utilisateur de contrôler la résistance chimique du détecteur par rapport au
produit de nettoyage utilisé. Vous trouverez de plus amples informations sur le site du fabricant: www.baumer.com
3°
>
3°
>

Other Baumer Accessories manuals

Baumer UNCK 09U6914 User manual

Baumer

Baumer UNCK 09U6914 User manual

Baumer 10155032 User manual

Baumer

Baumer 10155032 User manual

Baumer UNAM 12P3914/S14 User manual

Baumer

Baumer UNAM 12P3914/S14 User manual

Baumer 10158526 User manual

Baumer

Baumer 10158526 User manual

Baumer qTarget OT500 User manual

Baumer

Baumer qTarget OT500 User manual

Baumer GIM700DR User manual

Baumer

Baumer GIM700DR User manual

Baumer OM70-11220169 User manual

Baumer

Baumer OM70-11220169 User manual

Baumer UNAM 12P3912/S14 User manual

Baumer

Baumer UNAM 12P3912/S14 User manual

Baumer 10162128 User manual

Baumer

Baumer 10162128 User manual

Baumer OHDM 16N5651 User manual

Baumer

Baumer OHDM 16N5651 User manual

Baumer GIM500R User manual

Baumer

Baumer GIM500R User manual

Baumer OM70-11200090 User manual

Baumer

Baumer OM70-11200090 User manual

Baumer OBDM 12P6940/S35A User manual

Baumer

Baumer OBDM 12P6940/S35A User manual

Baumer UNAR 18N6912/S14G User manual

Baumer

Baumer UNAR 18N6912/S14G User manual

Baumer OADM 20U2472/S14C User manual

Baumer

Baumer OADM 20U2472/S14C User manual

Baumer FKDM 22P1902/S14F User manual

Baumer

Baumer FKDM 22P1902/S14F User manual

Baumer UNAM 18N6903/S14 User manual

Baumer

Baumer UNAM 18N6903/S14 User manual

Baumer UNDK 20N7914/S35A User manual

Baumer

Baumer UNDK 20N7914/S35A User manual

Baumer OX200 User manual

Baumer

Baumer OX200 User manual

Baumer R600V.DAE0-11209335 User manual

Baumer

Baumer R600V.DAE0-11209335 User manual

Baumer FVDK 10P66Z0 User manual

Baumer

Baumer FVDK 10P66Z0 User manual

Baumer DENEX Edge Detector II User manual

Baumer

Baumer DENEX Edge Detector II User manual

Baumer OADM 20I5571/S14C User manual

Baumer

Baumer OADM 20I5571/S14C User manual

Baumer UNAM 18P6903/S14H User manual

Baumer

Baumer UNAM 18P6903/S14H User manual

Popular Accessories manuals by other brands

BAZZ WFDBELL1 instructions

BAZZ

BAZZ WFDBELL1 instructions

RayTek CI Series quick start guide

RayTek

RayTek CI Series quick start guide

PCB Piezotronics ICP W112A21 Installation and operating manual

PCB Piezotronics

PCB Piezotronics ICP W112A21 Installation and operating manual

Loadrite Force Operator's manual

Loadrite

Loadrite Force Operator's manual

StarTech.com ST124HD20 quick start guide

StarTech.com

StarTech.com ST124HD20 quick start guide

nooie SA10 quick start guide

nooie

nooie SA10 quick start guide

Balluff IO-Link BLA D Series user guide

Balluff

Balluff IO-Link BLA D Series user guide

Dragino LSE01 user manual

Dragino

Dragino LSE01 user manual

Sencor SWD 130 user manual

Sencor

Sencor SWD 130 user manual

Balluff IO-Link BES M12EH1-L01C40B-S04G-L04 Configuration

Balluff

Balluff IO-Link BES M12EH1-L01C40B-S04G-L04 Configuration

FIBARO FGFS-101 user manual

FIBARO

FIBARO FGFS-101 user manual

Popp POPE700892 quick start

Popp

Popp POPE700892 quick start

Dimplex DHDEHT instruction manual

Dimplex

Dimplex DHDEHT instruction manual

Termozeta TZR61 instruction manual

Termozeta

Termozeta TZR61 instruction manual

Mobicool V30DC Operating and safety instructions

Mobicool

Mobicool V30DC Operating and safety instructions

Siko MSK500/1 quick start guide

Siko

Siko MSK500/1 quick start guide

Dometic CFF Short Operating Manual

Dometic

Dometic CFF Short Operating Manual

Redsbaby JIVE 3 Product guide

Redsbaby

Redsbaby JIVE 3 Product guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.