manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Baxi
  6. •
  7. Boiler
  8. •
  9. Baxi Boston 2 OF Operation instructions

Baxi Boston 2 OF Operation instructions

Other Baxi Boiler manuals

Baxi Power HT Series User manual

Baxi

Baxi Power HT Series User manual

Baxi MainEco Combi 24 User manual

Baxi

Baxi MainEco Combi 24 User manual

Baxi Luna 3+ User manual

Baxi

Baxi Luna 3+ User manual

Baxi 100/2 HE Plus Operation instructions

Baxi

Baxi 100/2 HE Plus Operation instructions

Baxi Duo-tec 2 Combi GA Range Release note

Baxi

Baxi Duo-tec 2 Combi GA Range Release note

Baxi Duo-tec Combi HE A User manual

Baxi

Baxi Duo-tec Combi HE A User manual

Baxi 35/60 Operation instructions

Baxi

Baxi 35/60 Operation instructions

Baxi Barselona User manual

Baxi

Baxi Barselona User manual

Baxi Nuvola 3+ BS40 User manual

Baxi

Baxi Nuvola 3+ BS40 User manual

Baxi Solo 3 User guide

Baxi

Baxi Solo 3 User guide

Baxi Fourtech Series User manual

Baxi

Baxi Fourtech Series User manual

Baxi Combi 624 Manual

Baxi

Baxi Combi 624 Manual

Baxi POWER HTE Series User manual

Baxi

Baxi POWER HTE Series User manual

Baxi Combi 130 HE Operation instructions

Baxi

Baxi Combi 130 HE Operation instructions

Baxi Combi 80 Maxflue User guide

Baxi

Baxi Combi 80 Maxflue User guide

Baxi DUO-TEC COMPACT Guide

Baxi

Baxi DUO-TEC COMPACT Guide

Baxi 50 HE Plus Release note

Baxi

Baxi 50 HE Plus Release note

Baxi Bermuda BBU 15 HE Release note

Baxi

Baxi Bermuda BBU 15 HE Release note

Baxi Bermuda SP3 User manual

Baxi

Baxi Bermuda SP3 User manual

Baxi Heat 412 User manual

Baxi

Baxi Heat 412 User manual

Baxi Combi 80e Release note

Baxi

Baxi Combi 80e Release note

Baxi Combi 825 User manual

Baxi

Baxi Combi 825 User manual

Baxi COMBI 224 Manual

Baxi

Baxi COMBI 224 Manual

Baxi Megaflo System 28 HE IE LPG Release note

Baxi

Baxi Megaflo System 28 HE IE LPG Release note

Popular Boiler manuals by other brands

Ferroli DOMIcompact F 30 D null

Ferroli

Ferroli DOMIcompact F 30 D null

Vaillant uniSTOR VIH SW GB 500 BES operating instructions

Vaillant

Vaillant uniSTOR VIH SW GB 500 BES operating instructions

Radijator BIO max 23.1 instruction manual

Radijator

Radijator BIO max 23.1 instruction manual

Brunner BSV 20 Instructions for use

Brunner

Brunner BSV 20 Instructions for use

Buderus Logamax GB062-24 KDE H V2 Service manual

Buderus

Buderus Logamax GB062-24 KDE H V2 Service manual

Potterton 50e Installation and Servicing Manual

Potterton

Potterton 50e Installation and Servicing Manual

UTICA BOILERS TriFire Assembly instructions

UTICA BOILERS

UTICA BOILERS TriFire Assembly instructions

Joannes LADY Series Installation and maintenance manual

Joannes

Joannes LADY Series Installation and maintenance manual

ECR International UB90-125 Installation, operation & maintenance manual

ECR International

ECR International UB90-125 Installation, operation & maintenance manual

Froling P4 Pellet 8 - 105 installation instructions

Froling

Froling P4 Pellet 8 - 105 installation instructions

Froling FHG Turbo 3000 operating instructions

Froling

Froling FHG Turbo 3000 operating instructions

U.S. Boiler Company K2 operating instructions

U.S. Boiler Company

U.S. Boiler Company K2 operating instructions

Henrad C95 FF user guide

Henrad

Henrad C95 FF user guide

NeOvo EcoNox EF 36 user guide

NeOvo

NeOvo EcoNox EF 36 user guide

Potterton PROMAX SL 12 user guide

Potterton

Potterton PROMAX SL 12 user guide

Eco Hometec EC 25 COMPACT Technical manual

Eco Hometec

Eco Hometec EC 25 COMPACT Technical manual

Viessmann VITODENS 200 Operating instructions and user's information manual

Viessmann

Viessmann VITODENS 200 Operating instructions and user's information manual

REXNOVA ISA 20 BITHERMAL Installation, use and maintenance manual

REXNOVA

REXNOVA ISA 20 BITHERMAL Installation, use and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Please keep these Instructions safe.
Should you move house, please hand
them over to the next occupier.
Baxi Boston 2 OF
Floor Standing Room Sealed
Gas Fired Central Heating Boilers
Comp N°235306 - Iss 4 - 7/00
User’s Operating
Instructions
OPERATING YOUR BOSTON 2 - Page 2
Natural Gas Your Baxi Boston 2 is a gas fired, open flued central heating boiler providing
heating for your home and domestic hot water where required.
Baxi Boston 2 80 OF
G.C. No. 41 077 84
Baxi Boston 2 70 OF
G.C. No. 41 077 83
Baxi Boston 2 60 OF
G.C. No. 41 077 82
Baxi Boston 2 50 OF
G.C. No. 41 077 81
Baxi Boston 2 40 OF
G.C. No. 41 077 80
Baxi UK Limited is one of the leading
manufacturers of domestic heating
products in the UK.
Our first priority is to give a high quality
service to our customers. Quality is built
into every Baxi product - products
which fulfil the demands and needs of
customers, offering choice, efficiency
and reliability.
To keep ahead of changing trends, we
have made a commitment to develop
new ideas using the latest technology –
with the aim of continuing to make the
products that customers want to buy.
Baxi is also the largest manufacturing
partnership in the country. Everyone
who works at the company has a
commitment to quality because, as
shareholders, we know that satisfied
customers mean continued success.
We hope you get a satisfactory service
from Baxi. If not, please let us know.
All CORGI registered installers carry a
CORGI identification card and have a
registration number. Both should be
recorded in your boiler Log Book. You
can check your installer is registered by
telephoning
01256 372300 or writing to:-
1 Elmwood,
Chineham Business Park,
1 Remove door panel as shown.
2 Turn the boiler thermostat knob to
the ‘OFF’ position fully anti-clockwise.
3 Turn on the main gas and electricity
supplies to the appliance.
4 To light the pilot: Looking through
the pilot viewing window press the gas
control knob fully inwards and hold.
Press in igniter button and release.
Repeat until pilot ignites. Continue to
hold in gas control knob for
approximately 15 seconds and then
release. Pilot should stay alight.
NOTE: If pilot fails to remain alight or is
extinguished at any time, wait at least 3
minutes then repeat the procedure from
the start of section “4”. Once the pilot is
alight it may be left on permanently.
5 To light the boiler: Ensure that all
external controls, e.g. room thermostat,
timer, etc. are calling for heat. Turn
boiler thermostat fully clockwise to high
setting. Main burner will then light.
The optimum boiler setting depends
upon type of system, external controls
and your requirements. Your installer
will be able to advise you on this
matter.
NOTE:If the pilot light is persistently
extinguished the flue system may be
unsound. Your installer or local gas
region should be contacted as soon as
possible in such circumstances.
“Benchmark” Installation,
Commissioning and Service Record
Log Book
Please ensure that your Installer has
completed the installation and
Commissioning sections of the Log
Book, and hands the Log Book over.
The details of the Log Book will be
required in the event of any warranty
work. Keep the Log Book in a safe
place and ensure that the relevant
sections are completed at each
subsequent regular service visit.
Baxi is a BS-EN ISO 9001
Accredited Company
Crockford Lane,
Basingstoke. RG24 8WG
Page 3
TO SHUT DOWN THE BOILER CLEARANCES AROUND THE BOILER
1 Turn off the electricity supply to the
appliance at the mains.
2 To turn off the pilot: Turn gas
control knob to off position marked 0.
NOTE: The gas control knob cannot
be depressed until ignition restart
interlock device in gas valve has
disengaged. This takes 60 seconds
approximately.
3 Turn off the gas supply at either the
appliance gas cock or the meter.
If your home is to be left unoccupied for
long periods during cold weather, the
whole system should be drained,
unless a frost-stat is fitted. Your
installer will advise you about draining
the system.
The minimum clear spaces needed
around the boiler are:
Top: 100mm (4 in)
Sides: See Below
Front:
(In Use) 5mm (3/16 in)
(For Servicing) 400mm (15¾ in)
If the boiler is fitted in a
compartment, this should be fitted
with ventilation openings at high and
low level which must not be blocked.
Occasional checks should be made
to ensure they are clear. The
compartment should be large
enough to house the boiler and
ancillary equipment only.
IT SHOULD NOT BE USED AS A
STORAGE CUPBOARD.
400mm is required for servicing.
5mm is required when operating.
These clearances must not be
obstructed in any way. Blocking the
clearance spaces will result in the
appliance overheating and damage
may possibly occur.
Warnings
IN CASE OF GAS LEAKS
If a gas leak is found or suspected, turn off the gas supply
at the meter immediately and contact your Installer or British
Gas Emergency (under ‘Gas’ in the phone directory).
NEVER HANG CLOTHES OR OTHER ITEMS OVER THE
APPLIANCE.
SERVICING YOUR BOILER
We strongly recommend that your boiler is serviced annually
for economic and safety reasons. Your Installer or British
Gas Service will be able to advise you.
THIS APPLIANCE MUST BE EARTHED
Electricity supply:
A standard 230 volt ~ 50Hz supply is required. The
appliance must be protected by a 3 amp fuse.
SAFE INSTALLATION
Installation of this appliance must be carried out by a CORGI
Registered Installer or other competent person and be in
accordance with the relevant requirements of the GAS
SAFETY (Installation and Use) REGULATIONS and any
other regulations applying in your area.
Page 4
CLEANING THE CASE
The painted panels should be wiped with a damp cloth and
then dried completely. DO NOT USE ABRASIVE
CLEANING AGENTS.
SPARE PARTS
Any repairs to the appliance will usually be the responsibility
of the Installer during the guarantee period after which spare
parts may be obtained through approved Baxi stockists if
required. Quote the appliance name, model number and
where possible the part number when ordering spares. (A
parts list is included in the Installation and Servicing
Instructions.)
GUARANTEE
Your BAXI BOSTON 2 is designed and produced to meet all
the relevant British Standards.
Baxi UK Limited provide a 12 month guarantee on the Boiler
- other parts of the system are covered by the Installer or
other manufacturers. The guarantee operates from the date
installation is completed for the customer who is the original
user.
To maximise the benefit from our guarantee we urge you to
return the reply-paid guarantee registration.
This does not in any way prejudice your rights at Common
Law. Such rights between the customer and the installer or
supplier from whom the unit was purchased remain intact.
Any component or part which becomes defective during
the guarantee period as a result of faulty workmanship
or material whilst in normal use will be repaired or
replaced free of charge.