manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Baxi
  6. •
  7. Boiler
  8. •
  9. Baxi Boston 2 OF Operation instructions

Baxi Boston 2 OF Operation instructions

Other Baxi Boiler manuals

Baxi PRIME 24 User manual

Baxi

Baxi PRIME 24 User manual

Baxi Boston 2 80 RS Operation instructions

Baxi

Baxi Boston 2 80 RS Operation instructions

Baxi Duo-tec Combi HE LPG Operation instructions

Baxi

Baxi Duo-tec Combi HE LPG Operation instructions

Baxi Combi 630 User manual

Baxi

Baxi Combi 630 User manual

Baxi Solo 3 User guide

Baxi

Baxi Solo 3 User guide

Baxi Combi Instant 80 HE Release note

Baxi

Baxi Combi Instant 80 HE Release note

Baxi Combi Instant 80 HE Release note

Baxi

Baxi Combi Instant 80 HE Release note

Baxi Neta-tec Combi GA Range Quick start guide

Baxi

Baxi Neta-tec Combi GA Range Quick start guide

Baxi Combi 80e Operation instructions

Baxi

Baxi Combi 80e Operation instructions

Baxi Luna 310 Fi User manual

Baxi

Baxi Luna 310 Fi User manual

Baxi LUNA DUO-TEC 60 GA User manual

Baxi

Baxi LUNA DUO-TEC 60 GA User manual

Baxi PRIME HT 240 User manual

Baxi

Baxi PRIME HT 240 User manual

Baxi PRIME Series User manual

Baxi

Baxi PRIME Series User manual

Baxi CPA-BTH Series User manual

Baxi

Baxi CPA-BTH Series User manual

Baxi Solo 3 30 PF User guide

Baxi

Baxi Solo 3 30 PF User guide

Baxi Luna Platinum 1.12 User manual

Baxi

Baxi Luna Platinum 1.12 User manual

Baxi Solo WM 30/4 PF User manual

Baxi

Baxi Solo WM 30/4 PF User manual

Baxi Duo-tec 2 Combi GA Range Instruction Manual

Baxi

Baxi Duo-tec 2 Combi GA Range Instruction Manual

Baxi Heat 616 Manual

Baxi

Baxi Heat 616 Manual

Baxi ECO4S 24 F Assembly instructions

Baxi

Baxi ECO4S 24 F Assembly instructions

Baxi Bermuda SP3 User guide

Baxi

Baxi Bermuda SP3 User guide

Baxi Combi 80 Maxflue User guide

Baxi

Baxi Combi 80 Maxflue User guide

Baxi Luna 310 Fi User guide

Baxi

Baxi Luna 310 Fi User guide

Baxi DUO-TEC COMPACT Guide

Baxi

Baxi DUO-TEC COMPACT Guide

Popular Boiler manuals by other brands

IDEAL IMAX XTRA EL 320 user guide

IDEAL

IDEAL IMAX XTRA EL 320 user guide

UTICA BOILERS BC3D Installation, operation & maintenance manual

UTICA BOILERS

UTICA BOILERS BC3D Installation, operation & maintenance manual

Lochinvar SOLUTION 260000 Installation & service manual

Lochinvar

Lochinvar SOLUTION 260000 Installation & service manual

Weil-McLain EG 6 Series manual

Weil-McLain

Weil-McLain EG 6 Series manual

RBI LCD Series Installation & operation manual

RBI

RBI LCD Series Installation & operation manual

Unical ALKON R 24 Installation and Servicing Manual

Unical

Unical ALKON R 24 Installation and Servicing Manual

Automatic Heating Gasogen Installation and Servicing Manual

Automatic Heating

Automatic Heating Gasogen Installation and Servicing Manual

Viessmann VITORADIAL 300-T Type VR3 Service instructions for contractors

Viessmann

Viessmann VITORADIAL 300-T Type VR3 Service instructions for contractors

Alpha GasSaver GS-1 Installation and servicing instructions

Alpha

Alpha GasSaver GS-1 Installation and servicing instructions

Vaillant uniSTOR VIH SW GB 500 BES operating instructions

Vaillant

Vaillant uniSTOR VIH SW GB 500 BES operating instructions

Kärcher HWE 4000 Gas manual

Kärcher

Kärcher HWE 4000 Gas manual

Radijator BIO max 23.1 instruction manual

Radijator

Radijator BIO max 23.1 instruction manual

Granby BKC Installation, operation and maintenance manual

Granby

Granby BKC Installation, operation and maintenance manual

Brunner BSV 20 Instructions for use

Brunner

Brunner BSV 20 Instructions for use

Potterton 50e Installation and Servicing Manual

Potterton

Potterton 50e Installation and Servicing Manual

UTICA BOILERS TriFire Assembly instructions

UTICA BOILERS

UTICA BOILERS TriFire Assembly instructions

ECR International UB90-125 Installation, operation & maintenance manual

ECR International

ECR International UB90-125 Installation, operation & maintenance manual

Froling P4 Pellet 8 - 105 installation instructions

Froling

Froling P4 Pellet 8 - 105 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Please keep these Instructions safe.
Should you move house, please hand
them over to the next occupier.
Baxi Boston 2 OF
Floor Standing Room Sealed
Gas Fired Central Heating Boilers
Comp N°235306 - Iss 4 - 7/00
User’s Operating
Instructions
OPERATING YOUR BOSTON 2 - Page 2
Natural Gas Your Baxi Boston 2 is a gas fired, open flued central heating boiler providing
heating for your home and domestic hot water where required.
Baxi Boston 2 80 OF
G.C. No. 41 077 84
Baxi Boston 2 70 OF
G.C. No. 41 077 83
Baxi Boston 2 60 OF
G.C. No. 41 077 82
Baxi Boston 2 50 OF
G.C. No. 41 077 81
Baxi Boston 2 40 OF
G.C. No. 41 077 80
Baxi UK Limited is one of the leading
manufacturers of domestic heating
products in the UK.
Our first priority is to give a high quality
service to our customers. Quality is built
into every Baxi product - products
which fulfil the demands and needs of
customers, offering choice, efficiency
and reliability.
To keep ahead of changing trends, we
have made a commitment to develop
new ideas using the latest technology –
with the aim of continuing to make the
products that customers want to buy.
Baxi is also the largest manufacturing
partnership in the country. Everyone
who works at the company has a
commitment to quality because, as
shareholders, we know that satisfied
customers mean continued success.
We hope you get a satisfactory service
from Baxi. If not, please let us know.
All CORGI registered installers carry a
CORGI identification card and have a
registration number. Both should be
recorded in your boiler Log Book. You
can check your installer is registered by
telephoning
01256 372300 or writing to:-
1 Elmwood,
Chineham Business Park,
1 Remove door panel as shown.
2 Turn the boiler thermostat knob to
the ‘OFF’ position fully anti-clockwise.
3 Turn on the main gas and electricity
supplies to the appliance.
4 To light the pilot: Looking through
the pilot viewing window press the gas
control knob fully inwards and hold.
Press in igniter button and release.
Repeat until pilot ignites. Continue to
hold in gas control knob for
approximately 15 seconds and then
release. Pilot should stay alight.
NOTE: If pilot fails to remain alight or is
extinguished at any time, wait at least 3
minutes then repeat the procedure from
the start of section “4”. Once the pilot is
alight it may be left on permanently.
5 To light the boiler: Ensure that all
external controls, e.g. room thermostat,
timer, etc. are calling for heat. Turn
boiler thermostat fully clockwise to high
setting. Main burner will then light.
The optimum boiler setting depends
upon type of system, external controls
and your requirements. Your installer
will be able to advise you on this
matter.
NOTE:If the pilot light is persistently
extinguished the flue system may be
unsound. Your installer or local gas
region should be contacted as soon as
possible in such circumstances.
“Benchmark” Installation,
Commissioning and Service Record
Log Book
Please ensure that your Installer has
completed the installation and
Commissioning sections of the Log
Book, and hands the Log Book over.
The details of the Log Book will be
required in the event of any warranty
work. Keep the Log Book in a safe
place and ensure that the relevant
sections are completed at each
subsequent regular service visit.
Baxi is a BS-EN ISO 9001
Accredited Company
Crockford Lane,
Basingstoke. RG24 8WG
Page 3
TO SHUT DOWN THE BOILER CLEARANCES AROUND THE BOILER
1 Turn off the electricity supply to the
appliance at the mains.
2 To turn off the pilot: Turn gas
control knob to off position marked 0.
NOTE: The gas control knob cannot
be depressed until ignition restart
interlock device in gas valve has
disengaged. This takes 60 seconds
approximately.
3 Turn off the gas supply at either the
appliance gas cock or the meter.
If your home is to be left unoccupied for
long periods during cold weather, the
whole system should be drained,
unless a frost-stat is fitted. Your
installer will advise you about draining
the system.
The minimum clear spaces needed
around the boiler are:
Top: 100mm (4 in)
Sides: See Below
Front:
(In Use) 5mm (3/16 in)
(For Servicing) 400mm (15¾ in)
If the boiler is fitted in a
compartment, this should be fitted
with ventilation openings at high and
low level which must not be blocked.
Occasional checks should be made
to ensure they are clear. The
compartment should be large
enough to house the boiler and
ancillary equipment only.
IT SHOULD NOT BE USED AS A
STORAGE CUPBOARD.
400mm is required for servicing.
5mm is required when operating.
These clearances must not be
obstructed in any way. Blocking the
clearance spaces will result in the
appliance overheating and damage
may possibly occur.
Warnings
IN CASE OF GAS LEAKS
If a gas leak is found or suspected, turn off the gas supply
at the meter immediately and contact your Installer or British
Gas Emergency (under ‘Gas’ in the phone directory).
NEVER HANG CLOTHES OR OTHER ITEMS OVER THE
APPLIANCE.
SERVICING YOUR BOILER
We strongly recommend that your boiler is serviced annually
for economic and safety reasons. Your Installer or British
Gas Service will be able to advise you.
THIS APPLIANCE MUST BE EARTHED
Electricity supply:
A standard 230 volt ~ 50Hz supply is required. The
appliance must be protected by a 3 amp fuse.
SAFE INSTALLATION
Installation of this appliance must be carried out by a CORGI
Registered Installer or other competent person and be in
accordance with the relevant requirements of the GAS
SAFETY (Installation and Use) REGULATIONS and any
other regulations applying in your area.
Page 4
CLEANING THE CASE
The painted panels should be wiped with a damp cloth and
then dried completely. DO NOT USE ABRASIVE
CLEANING AGENTS.
SPARE PARTS
Any repairs to the appliance will usually be the responsibility
of the Installer during the guarantee period after which spare
parts may be obtained through approved Baxi stockists if
required. Quote the appliance name, model number and
where possible the part number when ordering spares. (A
parts list is included in the Installation and Servicing
Instructions.)
GUARANTEE
Your BAXI BOSTON 2 is designed and produced to meet all
the relevant British Standards.
Baxi UK Limited provide a 12 month guarantee on the Boiler
- other parts of the system are covered by the Installer or
other manufacturers. The guarantee operates from the date
installation is completed for the customer who is the original
user.
To maximise the benefit from our guarantee we urge you to
return the reply-paid guarantee registration.
This does not in any way prejudice your rights at Common
Law. Such rights between the customer and the installer or
supplier from whom the unit was purchased remain intact.
Any component or part which becomes defective during
the guarantee period as a result of faulty workmanship
or material whilst in normal use will be repaired or
replaced free of charge.
Click here for Helplines