Bayrol PM5-REL-4 User manual

User Manual
for
PM5-REL-4 Relay Module
Plug-in module with 4 relay switch outputs
(max 3A at 230V~/30V=)
Order No : 127 016
Status as at 10 04 2013
Compatible with
PoolManager
®
PoolManager
®
PRO
Analyt

PM5-REL-4 Relay Module – User Manual 2
1 Identification of safety information
Please refer to the information concerning the
identification of safety information in your PoolManager
®
or Analyt user manual.
2 General safety information
HAZARD!
Please follo the general safety information
in your PoolManager
®
or Analyt user m
anual
carefully.
3 User qualification
Please refer to the different user qualifications as defined
in your PoolManager
®
or Analyt user manual.
4 O er iew
The PM5-REL-4 Relay Module is a plug-in module for the
BAYROL Measuring, Control und Dosing Systems
PoolManager
®
and Analyt of the 5th generation (from
2012). It provides 4 additional relay outputs hich can be
flexibly used for various add-on functions. Each single
relay can s itch max. 3A at 230V~or 30V=.
5 Installation
This chapter describes the installation of the PM5-REL-4
plug-in module inside the PoolManager
®
controller and
the cable connections.
Required user qualification:
ELECTRICAL SPECIALIST
Electrical connection may only be performed by
an ELECTRICAL SPECIALIST as defined in the
chapter User qualification of
your PoolManager
®
or Analyt user manual
.
5.1 Opening the casing
HAZARD DUE TO VOLTAGE!
Inside the controller you may get in touch ith
dangerous electrical voltages.
Potential consequence: Death or the gra est
degree of injury.
Disconnect the controller from mains po er
supply before opening the casing and
, in
particular, the lid of the connection terminal box.
IMPORTANT NOTICE!
Open on the right
Never open the casing on the left side, as
damage may other ise occur.
Al ays open on the right side!
1. Firmly press the hinge on the right side out and to
the right.
2. Remove the cover plate and unhook the hinge on the
bottom.
3. S ing the casing cover open to the left.

PM5-REL-4 Relay Module – User Manual 3
4. Unbolt the four scre s of the lid of the connection
terminal box and remove the lid. Take out the
aluminium rail after ards.
5. To close the casing, reverse this procedure.
5.2 Insert the PM5-REL-4 plug-in module
1. Each of the plug-in connectors 1 to 3 can be used for
the PM5-REL-4 plug-in module. For an optimal cable
route, e recommend to use plug-in connector 3 (on
the right)
2. Dismantle the cable (or cables) on the required
length inside the casing and insert it (them) into the
casing through one or more cable glands.
3. No connect the cable ends to the connection
terminals of the PM5-REL-4 plug-in module.
OUT5..OUT8 identify the 4 relay s itch outputs that
can later be selected in the menu. OUT5 and OUT6
are changeover s itches as sho n in the figure
belo .
4. Insert the PM5-REL-4 plug-in module carefully into
the plug-in connector 3 (on the right).
HAZARD!
Improper positioning
Improper (inaccurate) positioning of the plug-
in module and applying too
strong forces
may bent or even break the contact
pins of
the plug-in connector.
Potential consequence:
Irreparable
damage
of the plug-in connector, need for
factory
repair ser ice.
Take care for the correct
and accurate
position of the plug-in module and
do not
apply too strong forces.

PM5-REL-4 Relay Module – User Manual 4
5. No insert the aluminium rail at its original position.
Take care that the PM5-REL-4 plug-in module is
exactly located in the corresponding slot of the
aluminium rail as sho n on the second photo belo .
6. Remount the lid of the connection terminal box and
close the controller casing.
7. After completion and verification of the installation
you can reconnect mains po er supply to the
PoolManager
®
controller.
6 Menu Configuration
The relay s itch outputs OUT5..OUT8 can flexibly be
assigned to various add-on functions of the
PoolManager
®
in the same ay as the internal standard
relay s itch outputs.
The assignment is done in the Menus of the individual
add-on functions, e.g. Switch output 1..4, Filter pump or
Heating. In den Menus for the individual add-on functions
there is al ays a sub-menu called asic configuration. In
this sub-menu, the used relay s itch outputs can be
assigned, amongst others.
The figure sho s an example of a menu for the
assignment of a relay s itch output.
The relay s itch outputs of the PM5-REL-4 plug-in
module are named OUT5[REL4], OUT6[REL4],
OUT7[REL4] and OUT8[REL4] in the menu.
Relay s itch outputs hich have already been assigned,
are greyed out and cannot be selected anymore. If no
PM5-REL-4 module is plugged-in, all of the outputs
OUT5..OUT8 are greyed out and cannot be selected.
For further details, please refer to the description of the
individual add-on functions in the PoolManager
®
-user
manual.
7 Technical Data
Max. s itching voltage AC~ 230V~
Max. s itching voltage DC= 30V=
Max. s itching current AC~/ DC= 3A~/3A=
Max. s itching cycles ca. 20.000 at 3A
OUT 5 / OUT 6 Changeover s itches
OUT 7 / OUT 8 On/off s itches
• All relay s itch contacts are volts-free.
Hazard!
No electrical circuit protection
There is no internal fuse or other electrical
circuit protection for the relay s itch outputs.
Potential consequence: Damage or
destruction of connected de ices, risk of
fire.
•
Provide an appropriate external fuse or
other electrical circuit protection.
This manual suits for next models
1
Popular Relay manuals by other brands

GE
GE Multilin DFF instruction manual

Honeywell
Honeywell TRADELINE R8184G quick start guide

Tsubaki
Tsubaki TSBED Series instruction manual

VERIS INDUSTRIES, INC.
VERIS INDUSTRIES, INC. V102 installation guide

System Sensor
System Sensor i3 Series Installation and maintenance instructions

Basler
Basler H12345678 R U instruction manual