BEA PANTHER Series User manual

75.5172.08 PANTHER SERIES 20230420 Page 1 of 4
PANTHER SERIES
1
2
3
4
6
7
8
5
75.5172.08 PANTHER SERIES 20230420 Page 1 of 4
Push plate with integrated
900 MHz or 433 MHz wireless
transmitter
(US version)
ENGLISH
DESCRIPTION
1. Hex Key
2. Housing Assembly
3. Faceplate
4. Locking Tab
5. Mounting Bracket
6. Battery Enclosure
7. Mounting Keys
8. Mounting Holes
6 INCH ROUND, 433 MHz:
10EMR61 - logo & text
10EMR6 - text only
10EMR6L - logo only
4.75 INCH ROUND, 433 MHz:
10EMR4751 - logo & text
10EMR475 - text only
10EMR475L - logo only
4.75 INCH SQUARE, 433 MHz:
10EMS4751 - logo & text
10EMS475 - text only
10EMS475L - logo only
6 INCH ROUND, 900 MHz:
10EMR61-900 - logo & text
10EMR6-900 - text only
10EMR6L-900 - logo only
4.75 INCH ROUND, 900 MHz:
10EMR4751-900 - logo & text
10EMR475-900 - text only
10EMR475L-900 - logo only
4.75 INCH SQUARE, 900 MHz:
10EMS4751-900 - logo & text
10EMS475-900 - text only
10EMS475L-900 - logo only

Page 2 of 4 75.5172.08 PANTHER SERIES 20230420
2
3
4
1
Remove Housing Assembly from
Mounting Bracket by pressing in on
locking tab and sliding up.
Page 2 of 4 75.5172.08 PANTHER SERIES 20230420
• The device should not be used for purposes other than its intended use. All other uses cannot be
guaranteed by the manufacturer of the sensor.
• The installer of the door system is responsible for carrying out a risk assessment and installing the sensor and
the door system in compliance with applicable national and international regulations and standards on door
safety.
• The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate
adjustments of the sensor.
INSTALLATION
Install Mounting Bracket using at least
two (2) #8 countersunk head screws.
Any mounting holes may be used.
Observe “THIS END UP”.
Align Housing Assembly onto Mounting
Keys and slide down until Locking Tab
engages. To remove, press Locking Tab
and slide up.
Insert Faceplate into Housing Assembly
and use Hex Key to engage spring clips
on the top and bottom of Housing
Assembly. To remove, use Hex Key to
disengage spring clips.
NOTES:
1. For added security, additional screws may be installed through Housing Assembly and
Mounting Bracket during Step 2.
2. Ensure spring clips “click” during Faceplate installation. It may be necessary to rotate
Faceplate for proper alignment.

75.5172.08 PANTHER SERIES 20230420 Page 3 of 4
1
1
75.5172.08 PANTHER SERIES 20230420 Page 3 of 4
TROUBLESHOOTING
No activation Receiver not programmed Setup transmitter
Receiver improperly wired Verify power and activation
connection
Dead battery Replace battery
Constant activation Battery Housing screws
too tight
Loosen Battery Housing screws
Connected to door control
with NC (yellow) wire
Use NO (green) wire instead
Receiver set to Toggle
Mode
Set receiver to Pulse Mode
SETUP
To program the wireless receiver
(sold separately), please refer to the
appropriate User’s Guide:
• 900 MHz - 75.5786
• 433 MHz - 75.5092
• 433 MHz EH - 75.5659
900 MHz Panther series must use
a 900 MHz receiver and 433 MHz
Panther series must use a 433 MHz
receiver.
Remove four (4) screws on Battery
Enclosure.
• 900 MHz versions - two (2) CR2032
• 433 MHz versions - one (1) 12V
Type A23
DO NOT OVER TIGHTEN SCREWS
DURING REASSEMBLY. THIS MAY
CAUSE CONSTANT TRANSMITTER
ACTIVATION.
BATTERY REPLACEMENT

Page 4 of 4 75.5172.08 PANTHER SERIES 20230420
FCC ID: 2ABWS-10TD900PTRI IC: 4680-10TD900PTRI
MODEL: 10EMR61-900 MODEL: 10EMR4751-900 MODEL: 10EMS4751-900
MODEL: 10EMR6-900 MODEL: 10EMR475-900 MODEL: 10EMS475-900
MODEL: 10EMR6L-900 MODEL: 10EMR475L-900 MODEL: 10EMS475L-900
FCC ID: 2ABWS-10TD433PTRII IC: 4680-10TD433PTRII
MODEL: 10EMR61 MODEL: 10EMR4751 MODEL: 10EMS4751
MODEL: 10EMR6 MODEL: 10EMR475 MODEL: 10EMS475
MODEL: 10EMR6L MODEL: 10EMR475L MODEL: 10EMS475L
Page 4 of 4 75.5172.08 PANTHER SERIES 20230420
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device;
therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose.
BEA, Inc. strongly recommends that installation and service technicians be AAADM-certified for pedestrian doors, IDA-certified for doors/
gates, and factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring
that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer’s
recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must
be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g.
ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code).
Verify that all appropriate industry signage, warning labels, and placards are in place.
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
TECHNICAL SPECIFICATIONS
Dimensions 6” ROUND - 6.33” diameter, 1.45” depth
4.75” ROUND - 5.12” diameter, 1.42” depth
4.75” SQUARE - 5.12” height, 5.12” width, 1.42” depth
Weight 6” ROUND - 1.2 lbs
4.75” ROUND - 1.14 lbs
4.75” SQUARE - 1.04 lbs
Material FACEPLATE - stainless steel
HOUSING - ABS plastic
Transmitter Frequency 433 MHz or 900 MHz
Power 900 MHz versions - two (2) CR2032
433 MHz versions - one (1) 12V Type A23
Mounting Surface mount only
Certification FCC, IC
Temperature 14 °F - 131 °F (-10 °C - 55 °C)
Enclosure Rating NEMA 4
Specifications are subject to change without prior notice.
All values measured in specific conditions.
PLEASE KEEP FOR FURTHER USE - DESIGNED FOR COLOR PRINTING
©BEA|OriginalInstructions|75.5172.08PANTHERSERIES20230420
Tech Support & Customer Service: 1-800-523-2462
FCC / IC
“This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.”
Changes or modifications not expressly approved by BEA Incorporated could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions
suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est susceptible d’en compromettre le fonctionnement.
This manual suits for next models
18
Other BEA Control Unit manuals
Popular Control Unit manuals by other brands

Azbil
Azbil VDN user manual

Ross Controls
Ross Controls SAE Valves 80 Series manual

Asco
Asco 290 Series General Installation and Maintenance Instructions

Smartgen
Smartgen CMM366-4G user manual

Kohler
Kohler K-10675 installation guide

HP
HP ProCurve PCM+ Agent on ONE zl Module Product End-of-Life Disassembly Instructions

aquabrass
aquabrass 40255 installation guide

Spirax Sarco
Spirax Sarco 25P Installation and maintenance instructions

Allen-Bradley
Allen-Bradley D Series installation instructions

DOEPFER
DOEPFER A-100 Series user guide

Viessmann
Viessmann VITOTRONIC 300 Installation and service instructions

Extron electronics
Extron electronics DAV101CM Series Setup guide