Beam AS-375 User manual

UPS + AVR
Uninterruptible Power System
User’s Manual
AS-375
Not only for P.C., but also for Fax & Modem
BACKUP/FAULT NORMAL

Page 1 of 9
TABLE OF CONTENTS
1. INTRODUCTION ------------------------------------------------------- Page 2
2. MAIN FEATURES ------------------------------------------------------ Page 2
3. CAUTION ----------------------------------------------------------------- Page 2
4. INSTALLATION AND OPERATION ------------------------------- Page 3 – 4
5. INDICATION AND CONTROL --------------------------------------- Page 5
6. COMMUNICATION INTERFACE ---------------------------------- Page 6
7. TROUBLE SHOOTING ----------------------------------------------- Page 7
8. SPECIFICATIONS ----------------------------------------------------- Page 8
9. IMPORTANT SAFETY INSTRUCTIONS ------------------------ Page 9

Page 2 of 9
1. INTRODUCTION:
This is a high performance stand-by Uninterruptible Power Supply (UPS) designed
to protect your computer and fax machine from utility line failure. In the event of
utility failure (blackout), the UPS will rapidly transfer loads to an alternative power
source, which derives power from batteries set inside the UPS. The backup time for
a Pentium IV including 17”SVGA monitor is about 8 minutes, or 11 minutes for a
Pentium IV including 15” SVGA monitor.
2. MAIN FEATURE:
※'Green Power' based design with auto on/off function.
※Extra wide-range AVR function.
※Standard RS-232 port for monitoring function.
※Double protections for over load & short circuit.
※Auto test when turn on.
※Auto-detect input frequency 50Hz/60Hz.
3. CAUTION:
※The UPS is suitable for capacitate load, such as computer & PABX. However, it
is not suitable for inductive load, such as motor, fan, or laser printer.
※When installation, please make sure the load is not over the rated capacity of the
UPS. When blackouts happen LED will turn to red and alarm will beep if the
load is close to the rated value. Meantime, the UPS will shut down
automatically for protecting UPS itself.
※The UPS is shipped from the factory with fully charged internal batteries;
however, the batteries may lose some energy during delivery and storage. To
ensure that the UPS will provide the expected run-time, the UPS must be
charged for at least 6 hours before your first use. Please simply turn on the
UPS after installation when city power is normal, and the batteries will be
charged automatically.

Page 3 of 9
4. INSTALLATION & OPERATION:
※Rear Panel
1. Power Switch.
2. Input / Output Terminals of Fax Signal.
(Either one can be input or output)
3. DB9 Connector, for monitoring With P.C.
4. Inlet of City Power.
5. Outlet (Available for IEC as shown above, & NEMA , also available for
universal type with additional charge.).
4.1 Installation
4.1.1 Connecting the UPS & city power with the original power cord of your computer.
If an extension cord must be used between the UPS and the nearest wall outlet,
use a 3-wire grounding type with rated value for at least 5 Amps.
4.1.2 Connecting outlets & phone line as shown below.
4.1.3 Turning on power switch.
2 3 4
ON
OFF
1 55
Incoming Phone Line
Original Power Cord of your Computer
Fax Machine/Modem Computer
Enclosed Power Cord with UPS

Page 4 of 9
4.2 Operation:
4.2.1 When the power switch is turned on, UPS will go through the procedure of self-test
(about 3-4 sec.). If test result is O.K, the green LED will be on.
4.2.2 While if it is over loaded, the UPS will alarm. Or if the battery level is low, it will
emit quick beeps for several seconds and stay in normal mode for recharging.
Please also refer to the “LED/Alarm Indication” in item 5.3.
4.2.3 Green power function
When blackout occurs, the UPS will shutdown the power automatically within 30
seconds if the output power is lower than 25W.
4.2.4 Connecting the FAX machine:
When you are connecting a FAX machine or modem with the UPS, please also
connect the phone line through the UPS. The UPS may offer protection against
damaging power fluctuations and surges that travel through the phone line.
The UPS also offers a ring on function for fax receiving when blackout occurs.
UPS power will be turned on automatically when a ringing signal exists in the
phone line, and the UPS will keep power on until the FAX machine finishes
receiving work, then the UPS will be turned-off in 30 seconds by the green power
function. In a long-time blackout situation, you won’t miss any FAX data with this
function.
On the other hand, if you need to send out a fax during a blackout, please simply
pick up the phone receiver; then the UPS will wake up and keep power on until
your fax sending work is finished.

Page 5 of 9
5. INDICATION AND CONTROL
※Front Panel
5.1 Operation status LED
There are two LEDs showing the UPS status; in the normal utility power duration, Green
LED will show. While in the event of a utility outage, Red LED will flash. If the UPS is
under fault operation, Red LED will show continuously.
5.2 Audible alarm
During a utility failure or fault operation, the UPS emits beep for warning. In
back-up mode, the beeping will sound for urging user to leave computer without any
data loss.
5.3 LED/Alarm Indication:
*Green LED, no alarm --------------------------------------------- City power normal.
*Red LED flashing, two beeps / 4 sec. ----------------------- Backup mode.
*Red LED flashing, quick beeping, 4 beeps / sec --------- Low battery.
*Red LED lighting, continuous beep ---------------------- Over load
(180W up ---- Alarm & auto shut down in 30 sec.)
(210W up ---- Auto shut down immediately)
*Red LED flashing, one beep / 4 sec. -------------------------- No load (auto shut down after 30 sec.)
*Red + Green LEDs lighting, continuous beep ------------ Dead battery warning.
※If any abnormal condition occurs, and the UPS emit alarm continuously; please turn off
your PC in normal procedure, then turn off the UPS and wait for 3 sec, and turn on the
Switch to re-start the UPS.
BACKUP / FAULT NORMAL

Page 6 of 9
6. COMPUTER INTERFACE PORT
Pin2 : AC Power Failure
Pin4 : Common GND of Pin2 & Pin5
Pin5 : UPS Battery Low
Pin6 : Turn off UPS
Pin7 : GND of Pin6
The computer interface port is diagramed above for your reference. Use Pin4
as the common of Pin2 and Pin5, Pin2 and Pin4 will become close loop from
open when the utility is fail, Pin5 and Pin4 will become close loop from open
when the battery level is low.
The UPS will shut down when the high level signal from RS-232, sustained for 3
seconds, is applied between Pin6 and Pin7.
Computer
RS232 5 4 3 2 1
9 8 7 6

Page 7 of 9
7. TROUBLE SHOOTING:
Problem Possible Causes Action To Take
1. City power normal
without any LED
AC fuse broke?
Bad connection or
disconnection of power cord.
Change fuse.
Re-connect it.
2. Time of back up too
short
Battery life is due?
Blackout too often?
Change battery
Be sure charging time
3. Both LEDs (RED &
GRN) lighting with
continuous beep
Dead battery Change battery
4. Both LEDs (RED &
GRN) lighting with
continuous beep
Voltage of city power too
high/low
(<75% or >125% of rated
voltage)
Turn off your P.C./fax, and
wait city power back to
normal
Dead battery Change battery
Disconnection of battery
leads?
Re-connect it.
5. No any output when
blackout happen
UPS out of order? Call for service.

Page 8 of 9
8. SPECIFICATIONS:
MODEL AS-375
Capacity (Computer Load) 375VA (210W)
Input Voltage 100V/110V/115V/220V/230V/240V ± 25%
Frequency 50Hz/60Hz Auto-detect.
Output Voltage 100V/110V/220V/230V/240V ± 5% for Back-up Mode
<
<<
<±10% for AVR
Frequency 50Hz or 60Hz ± 0.1Hz
Wave Form Simulated Pseudo Sine Wave
Application of P.C. & Fax Machine Auto operation for either or both of P.C. & fax machine in use.
Runtime of one set of P.C. (typical)
(including 15”SVGA monitor)
11 minutes typical.
Runtime for fax more than 80 pages of receiving fax (A4 size)
Transfer Time 4ms typical.
Battery Lead-Acid, maintenance free
Voltage/Capacity 6V 4.5Ah X 2pcs
Recharge Time Approx. 8 hrs to 90%
LED/Alarm Indication
Normal/In Charge GRN LED, No Beep.
Back up / Abnormal Input Voltage RED LED Flashing, 2 Beeps / 4 sec.
Abnormal Input Frequency (Back up) RED LED Flashing, 2 Beeps/ 4 sec.
Power Saving (When No Load) RED LED Flashing,1 Beep / 4 sec. (Auto off in 30 sec.)
Low Battery RED LED Flashing, 4 Beeps / sec.
Over Load/Fault RED LED Lighting, Continuous Beep.
Dead Battery Warning RED & GRN LEDs Lighting, Continuous Beep.
Operation Temp 0-40℃
Operation Humidity 30-95% Non-Condensing
Dimensions (L*W*H) 27 x 29 x 6 (cm)
Shipping Dimensions (L*W*H) 44 x 39 x 39 (cm) / 2.3cft. (3pcs in 1 carton)
Weight (N.W./G.W.) 5.5/6.0 kgs
* Specifications subject to change without prior notice.

Page 9 of 9
9. IMPORTANT SAFETY INSTRUCTIONS
ϳWhen replacing the batteries, use the same number and the same type of batteries.
ϳDo not dispose of batteries in a fire; the battery may explode.
ϳDo not open or mutilate the battery or batteries, released electrolyte is harmful to the skin and eyes.
ϳA battery can present a risk of electric shock and high short circuit current. The following
precaution should be observed when working on batteries.
* Remove watches, rings or other metal objects.
* Use tools with insulated handles.
ϳTo prevent an overbalance of this unit, with the installation the additional stabilizer are to mount at
the bottom side.
ϳThis unit is to be installed by service personnel.
ϳThe equipment can be operated by any individual with no previous experience.
ϳ“The socket-outlet shall be installed near the equipment and easily accessible.”
ϳ“With the installation of this equipment it should be prevented, that the sum of the leakage current
of the UPS an the connected consumer does not exceed 3.5mA.”
ϳAttention, hazardous through electric shock. Also with disconnection of this unit from the main,
hazardous voltage still may be accessible through supply from battery.
ϳThe battery supply should be therefore disconnected in the plus and minus pole through the from
the outer enclosure accessible battery fuses when maintenance or service work inside the UPS is
considered.
ϳThe lead acid battery may cause chemical hazard.
ϳThe battery presents a risk of electric shock and energy hazard.
ϳBatteries are to be disposed by the manufacturer or importer. Customers need to send them
back with no charge for disposal.
ϳElectrical hazard, the discharge time is about 5 min.
German wording:
ϳWenn Sie die Batterien austauschen, verwenden Sie bitte die gleiche Anzahl und den gleichen
Batterietyp.
ϳWerfen Sie niemals die Batterien in das Feuer, die Batterien könnten explodieren.
ϳÖffnen oder beschädigen Sie nicht die Batterien, ausfileβendes Elektrolyt ist schädlich für Haut
und Augen.
ϳEine Batterie kann eine Gefahz eines elektrischer Schlages und sehr groβer Kurzschluβströme
beinhalten. Folgenda Vorkehrungen soiiten getroffen warden, wenn Sie mit der Battery arbeiten.
* Entfernen Sie Uhren, Ring and andere metallische Objekte.
* Verwenden Sie Werkzeug mit isolierten Griffen.
ϳUm ein Umkippen dieses Gerätes zu verhindern, sind mit der Installation dieses Gerätes die
zugätalichen Stützen an der Unterseite dieses Gerätes anzubringen.
ϳDieses Gerät ist durch Elektrofachkräfte zu installieren.
ϳBedienung durch jedermann ohne dem Vorkenntnisse.
ϳ“Die Steckdose muβnahe dem Gerät angebracht und leicht zugänglich sein.”
ϳ“Bei der Installation dieses Gerätes ist darauf zu achten, daβdie Summe der Ableitstöme der
USV und der angeschlossenen Verbraucher den Maximalwert von 3.5mA nicht Überschreiten.”
ϳ“Vorsicht, Gefahr durch elektrischen Schlag. Auch nach Trennung von der
Netzeingangsspannung werde Teile innerhalb der USV von der Batterie gespeist und führen
gefährliche Spannung.
ϳBei Instandhaltungsarbeiten ist daher die Versorgung durch die Batterie an den von auβen
zugänglichen Sicherungshaltern in beiden Polen zu unterbrechen.”
ϳDie Blei-Akkumulatoren Können bei unsachgemäβer Handhabung chemische Gefahren
hervorrufen.
ϳDie Batterie birgt eine Gefahr eines elektrischen Schlages und sehr hoher Kurzschluβstroeme.
ϳBatterien werden durch den Hersteller oder Importeur entsorgt. Dazu muessen die Batterien
kostenfrei angeliefert werden.
ϳGegahr durch elektrischen Schlag, die Entladeit dieser Kondensatoren beträgt 5 min.
Table of contents
Other Beam UPS manuals
Popular UPS manuals by other brands

CyberPower
CyberPower OR1500LCDRTXL2U user manual

socomec
socomec MASTERYS BC 15 Installation and operating manual

PowerShield
PowerShield Defender Series user manual

INFOSEC
INFOSEC XP PRO UPS 1000 VA user guide

INFOSEC UPS SYSTEM
INFOSEC UPS SYSTEM Zenergy Station 2000 user guide

ReDeal
ReDeal PC615N Series user manual