BeautyRelax CAVIMAX ULTIMATE BR-1950 User manual

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
1
U
US
SE
ER
R
M
MA
AN
NU
UA
AL
L
Aesthetic body shaping device
BeautyRelax BR-1950
CAVIMAX ULTIMATE

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
2

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
3
CONTENT:
INTRODUCTION 4
NOTICE 5
USING SONOGEL 5
CONTRAINDICATIONS 6
PROHIBITED AREAS OF TREATMENT 6
PERMITTED TREATMENT AREAS 6
LYMPH NODES 7
PROBLEMS OF ADIPOSE TISSUE 10
FAT CELL 10
STIMULATION OF ADIPOSE TISSUE BY ULTRASOUND 11
FOR ALL CHARACTER TYPES 11
INTRODUCTION OF THE DEVICE TECHNOLOGY 12
BODY SHAPING BY ULTRASOUND 12
ULTRASONIC WAVES 13
MAIN ADVANTAGES 14
WHAT YOU CAN EXPECT 14
DEVICE FEATURES 14
TECHNICAL PARAMETERS 14
PACKAGING CONTENT 14
DEVICE DESCRIPTION 15
FIRST CONNECTION OF THE DEVICE 17
HOW TO USE 18
OPTIMUM INTENSITY SETTING 19
TREATMENT TIME 20
CLEANING AND MAINTENANCE 20
UNIVERSAL MASSAGE TECHNIQUE 21
FREQUENTLY ASKED QUESTIONS AND ANSWERS 26
DISPOSAL OF USED ELECTRICAL AND ELECTRONIC EQUIPMENT 29
CERTIFICATION 29
IMPORTER 29

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
4
INTRODUCTION
Dear customer, thank you for your trust in purchasing our product. Please read all the detailed
information in the instruction manual carefully before using it for the first time. Please pay particular
attention to the warnings and safety notices. Use the appliance exactly as instructed. All of these
steps will help to maximize the use of all the functions of the instrument and protect everyone's
health. In this manual we will try to give you the best possible idea of the technology used and how
to use the instrument to best advantage.
Please do not take any of the instructions in this manual lightly. The aesthetic device for non-invasive
treatment of selected body parts works with technology that is painless and safe. The device has
undergone a long development process and meets all statutory safety standards in terms of safety. In
order to effectively stimulate the subcutaneous fat tissue, the device works with a certain power. If
you do not follow the instructions given, do not honor the warnings and the list of contraindications,
you can negatively affect your health in the extreme case. On the other hand, do not be afraid of
using the device. The design, features and technology are adapted for use in home conditions
without the supervision of a knowledgeable health care professional.
Introductory important information related to the device and its use:
The BeautyRelax aesthetic device belongs to the category of massage/aesthetic devices. It is
not a medical device. It does not serve to treat obesity or other related limitations. It offers
technologies that, when used under specific conditions, assist in the reduction of
subcutaneous fat.
The BeautyRelax aesthetic device provides a non-invasive treatment. In practice, this means
that no part of the application head physically penetrates under the skin.
• Non-invasive use is a prerequisite for the use of the device in home conditions by the
average user. Operation of the device does not require the supervision of an erudite trained
medical or cosmetic aesthetics professional.
• The BeautyRelax aesthetic device is certified and meets all the standards required for a
device of this kind. The safety of the adapter and all electronic components is ensured.
• The treatment is always combined with a clear conductive gel (sonogel). It can be purchased
at any pharmacy or health supply store. It costs a few tens of crowns. Definitely the cheapest
is enough. The more expensive the better. The main purpose of applying a fine layer of gel to
the skin is to increase conductivity. Ultrasound gets a better ability to penetrate the dermis
layer, where the structure of collagen and elastic fibers.
• It is definitely not true that the more frequent the use of the device, the faster the results.
Give your body enough time to process the energy that is released by using the machine.
This will make a significant contribution to protecting your health.
• If you are unsure about anything, if you are unsure at any stage of using the device, please do
manager Martin Hrbek is available to answer any questions or concerns you may have.
Keep the instructions for use carefully for later reference.
We wish the device to serve you well and meet the expectations you had before buying it.
BeautyRelax.cz team

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
5
NOTICE
Read this manual before first use, review all illustrations and keep the
manual for future reference.
If your skin is affected by a serious skin condition, do not use the
device. If you are unsure whether your medical condition is consistent
with the conditions for use of the device, consult your general
practitioner for suitability.
The device is primarily intended for your personal use. Do not share it
with family members or friends. If more than one person is using the device, special
attention should be paid to hygiene.
If the device is damaged, does not work properly or has fallen into the water, never put it
into operation.
If the unit is broken, do not touch the internal parts to avoid electric shock.
If the device falls to the ground, it may be damaged. In this case, do not continue to use the
instrument and contact the dealer's service department.
Do not use the device near water or in places with increased humidity (bath, shower,
swimming pool, etc.).
The device is not washable. It must not be immersed in water or under a stream of running
water.
Do not leave the device unattended. Always switch off the appliance thoroughly after each
use.
If the device has been moved from a very cold to a very warm environment, wait at least 3
hours before using it.
The appliance is not intended for use by children or persons whose physical or mental
condition does not permit the safe use of the appliance.
Do not place or use the device on hot heat sources (radiator, stove, fire, etc.)
Do not attempt to disassemble or repair the device yourself.
Store the device in a dry environment. Try to keep it protected from dust.
Do not expose the device to direct sunlight.
The distributor is not liable for damages caused by improper use contrary to the instructions
in this manual. It is not responsible for consequences caused by failure to observe the safety
warnings.
The distributor is not liable for any damage to health or property caused by other uses.
USING SONOGEL
Use is always combined with a clear conductive gel (not
included). The application gel, called SONOGEL, can be
purchased at any medical supply store (can also be
purchased at a pharmacy). The gel is very important for
the use of the device. It forms a necessary bonding layer
between the applicator and the skin. It is water-based. It
cannot harm the applicator head. The use of the
applicator gel is essential. This allows the ultrasound
waves to penetrate the skin more easily. Do not use any
other cosmetic products.

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
6
CONTRAINDICATIONS
Under no circumstances should the device be used by persons affected by any of these conditions:
Cancer, epilepsy, diabetes, viral diseases
In a state of high fever
Serious kidney or liver disease
High cholesterol
Skin diseases
Fatigue syndrome
Heart disease, pacemaker, hypertension
Metal implants in the body
Vascular disorders or arteosclerosis
Pregnancy
Menstruation
Persons taking anti-clotting medication
Patients who have undergone surgery with transplantation
Persons who require constant supervision may use the device only after consulting a
physician
PROHIBITED AREAS OF TREATMENT
Head (excluding the area under the chin in the narrow band)
The area where the heart is
Armpits
Elbow
Wrist
Knees
Ankle
Palms
Feet
Knee area
Spine
PERMITTED TREATMENT AREAS
Chin
Forearms
Pumps
Belly
Thighs
Ass
Calves
Note: the paired body area is taken as one part

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
7
LYMPH NODES - ULTRASOUND
When using the Beautyrelax device, try to avoid these areas of the lymph nodes. A light touch does
not matter. Constant stimulation of these nodes is not recommended. The nodes are shown with
large green dots:

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
8
LYMPH NODES - ULTRASOUND
When using the Beautyrelax device, try to avoid these areas of the lymph nodes. A light touch does
not matter. Constant stimulation of these nodes is not recommended. The nodes are shown with
large green dots:

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
9
LYMPH NODES - ULTRASOUND
When using the Beautyrelax device, try to avoid these areas of the lymph nodes. A light touch does
not matter. Constant stimulation of these nodes is not recommended. The nodes are shown with
large green dots:

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
10
PROBLEMS OF ADIPOSE TISSUE
Fat cells are among the largest cells found in the
human body. Their main purpose is to create a
supply of energy. In addition to storing energy, white
adipose tissue also serves as thermal insulation and
protection for internal organs. Adipose tissue is most
commonly found in the subcutaneous tissue.
Adipose tissue is one of the connective tissues. One
of the important properties of adipose tissue is the
accumulation of fat actively formed from
carbohydrates and fatty acids in the cells. The process of fat storage and breakdown is controlled by
hormonal and neural stimuli. White adipose tissue is composed of fat cells with large fat droplets
surrounded by a ring of cytoplasm (fat vacuole). The nucleus is located at the periphery of the cell.
The stored fat is semi-liquid in consistency and consists mainly of triacylglycerols and cholesterol
esters. In lean individuals, it occupies about 20% of body weight, but in obese individuals it can make
up to 50% of total weight.
FAT CELL
graphic animation of a cluster of fat cells
CELL NUCLEUS
MITOCHONDRIA
MEMBRAINE
FAT SUPPLY
CYTOPLASM
VESICLES OF THE GOLGI COMPLEX
HUNGRY
ENDOPLASMIC
RETICULUM
EPIDERMIS
DERMIS
FAT TISSUE

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
11
STIMULATION OF ADIPOSE TISSUE BY
ULTRASOUND
The main purpose of using aesthetic devices is to directly target the fat cells that accumulate in the
adipose tissue. Under the action of ultrasound waves, triglycerides are broken down into fatty acids
and glycerol. Glycerol is water soluble and is thus easily absorbed into the circulatory system. The
fatty acids are processed by the liver in a way that is natural and intrinsic to the body.
FOR ALL CHARACTER TYPES
The BeautyRelax is suitable for all body types. For both men and women. Whatever the
predisposition for greater fat deposition on any part. Exceptions are people who are subject to any of
the conditions listed in the list of contraindications.

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
12
INTRODUCTION OF THE DEVICE TECHNOLOGY
BeautyRelax Cavimax Ultimate is a modern device for shaping the body using ultrasonic waves. Its
uniqueness compared to devices of similar type lies in the possibility of power dosage. Thanks to this,
you can measure yourself on a body with different thicknesses of subcutaneous fat. Power dosing is
very important to achieve the desired weight loss results. The ultrasound waves are transmitted to
the body using an applicator with a large contact area. Use for the following body parts: chin, arms,
abdomen, buttocks, inner and outer thighs, calves. Suppresses signs of cellulite. The device is made
with a combination of the highest quality materials. Extremely long service life. Practical desktop
design. Modern elegant design.
BODY SHAPING BY ULTRASOUND
The application head with a large contact area generates ultrasound waves that actively stimulate
the fat tissue. The integrity of the fat cell is disrupted and the fat is released. The released fat is
broken down into glycerol and free fatty acids. The glycerol serves as an energy source, while the
fatty acids are transported to the liver where they are processed as normal fatty acids from food and
excreted out of the body naturally. The removed fat is not returned to the tissue. Ultrasound
cavitation is a painless, non-invasive, gentle, effective and most importantly permanent method for
removing fatty tissue, reducing cellulite and smoothing the skin.

Aesthetic body shaping device BeautyRelax BR
ULTRASONIC WAVES
The home cavitation device generates ultrasound waves through a large
application head, which penetrate the subcutaneous tissue. The tissues then
absorb this ultrasound energy. The integrity of the fat cell is compromised and
fat is released. The released fat is broken down into glycerol and free fatty
acids. The glycerol se
rves as an energy source, while the fatty acids are
transported to the liver where they are processed as normal fatty acids from
food and excreted out of the body naturally. The removed fat is not returned
to the tissue. Ultrasound cavitation is a painless
effective and most importantly permanent method for removing fatty tissue,
reducing cellulite and smoothing the skin.
application head
skin surface
dermis layer
adipose tissue
muscle tissue
Aesthetic body shaping device BeautyRelax BR
-1950 CAVIMAX ULTIMATE
13
ULTRASONIC WAVES
The home cavitation device generates ultrasound waves through a large
application head, which penetrate the subcutaneous tissue. The tissues then
absorb this ultrasound energy. The integrity of the fat cell is compromised and
fat is released. The released fat is broken down into glycerol and free fatty
rves as an energy source, while the fatty acids are
transported to the liver where they are processed as normal fatty acids from
food and excreted out of the body naturally. The removed fat is not returned
to the tissue. Ultrasound cavitation is a painless
, non-invasive, gentle,
effective and most importantly permanent method for removing fatty tissue,
reducing cellulite and smoothing the skin.
application head
skin surface
dermis layer
adipose tissue
muscle tissue
User manual

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
14
MAIN ADVANTAGES
Suppression of cellulite manifestations
Reduction of adipose tissue on selected body parts
Completely non-invasive nature of the treatment
Safe, painless use
Without any discomfort
Suitable for domestic and commercial use
WHAT YOU CAN EXPECT
Achievable and visible results even in cases where fat grows through muscle mass
(especially in men or athletic women)
removal of fat from problematic areas of the female and male body
shaping of prominent contours on the arms, legs and body
firming and tightening of the skin
DEVICE FEATURES
Applicator made of high quality stainless steel
Desktop version
High utility value
Extremely long device lifetime
Possibility to dose the power of ultrasonic waves
TECHNICAL PARAMETERS
Frequency range: 40 to 60KHz
Power: 60W
Dimensions: 34x26x10cm
Weight: 2.4kg
PACKAGING CONTENT
BeautyRelax BR-1950 base unit
Application head
Power adapter 220V
User manual

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
15
DEVICE DESCRIPTION
1
2
3
4
1. Application head
2. Intensity indicator
3. INTENSITY buttons - ultrasound intensity setting
4. ON/OFF button

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
16
DEVICE DESCRIPTION
1
2
3
4
1. Grid for cooling the device
2. Main ON/OFF button
3. Power adapter input
4. Input for application head

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
17
FIRST CONNECTION OF THE DEVICE
All cables must be properly connected before first use. Installation is very simple. There are inputs on
the back of the unit for connecting the application head and power adapter.
Step 1
Connect the application head connector (1). Secure by screwing in the thread. The threaded
fastening serves as a protection against pulling out due to unintentional pulling of the
cable.
Step 2
Connect the connector of the power adapter to the socket (2). Connect the other end of the
adapter to the 220V mains supply.
Step 3
You can then switch on the device using the main ON/OFF button (3). When the charging
adapter is correctly connected, the main ON/OFF button in position I lights up.
1
2
3

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
18
HOW TO USE
1. Skin should be thoroughly cleansed before each use. It is ideal to time your treatment after a
full body bath. No impurities should remain on the skin.
2. Apply a fine layer of clear contact gel (not included) to the area to be treated. The contact gel,
called SONOGEL, can be purchased at any medical supply store (it can also be purchased at a
pharmacy). The gel is very important for the use of the device. It forms a necessary bonding
layer between the application head and the skin. It is water-based. It cannot harm the
application head. The use of the application gel is essential. The device cannot be used without
the use of skin contact gel.
3. The treated body area should ideally be hair-free. This will improve the movement of the
application head over the skin. The ultrasound waves will penetrate the subcutaneous tissue
better.
4. Check that the application head and adapter cables are properly connected.
5. Always position the main unit of the device in such a way that the movement of the
application head on the selected part of the body does not cause the main unit to be knocked
off and fall to the ground.
6. Switch the main ON/OFF button on the back of the unit to position I. The ON/OFF button will
then light up.
7. The device is now in standby mode. Use the INTENSITY button to adjust the intensity of the
ultrasonic waves. The arrow (>) increases the intensity. Arrow (<) to decrease the intensity.
8. By pressing the ON/OFF button on the control panel, the application head starts to generate
ultrasonic waves.
9. The device can operate for a maximum of 30 minutes. After that it must be left to cool down
for at least 10 minutes. Do not switch off the appliance immediately after use. Leave in
standby mode.
10. You can switch the device off at any time by pressing the ON/OFF button.
11. To turn the unit off completely, switch the main ON/OFF button on the back of the main unit
to position 0.
12. Move the application head over the selected area in circular motions. NEVER stay in one place
with the applicator head.
13. Always ensure that the application head is in full contact with the skin. This will ensure
maximum treatment effectiveness.
14. If some parts of the cannon are harder to reach with the application head, ask your loved one
for help.
15. For more information on how to move the application head around the body, see the passage:
UNIVERSAL MASSAGE TECHNIQUE.
16. For more information on how to maintain the application head, see the passage:
CLEANING AND MAINTENANCE.

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
19
OPTIMUM INTENSITY SETTING
Everybody is an original. We have different thicknesses
of fatty tissue on different parts of the body.
Considering the different fat tissue, it is necessary to
work with the power of the device. When developing
the BeautyRelax BR-1950 aesthetic device, great
emphasis was placed on versatility of use. The dosage
of ultrasound power allows the device to be used by
anyone who meets the conditions of use and is not
affected by any condition listed as a contraindication.
On the control panel, you can set 5 intensity levels
from 1 to 5. The dosing frequency from 40Hz to 60Hz.
Corresponds to an energy release ranging from 35 to
60 joules per 1cm area2 .
In general, the larger the body part, the greater the
amount of subcutaneous fat. Therefore, it is necessary
to work with higher power.
So how do I know which power level to set correctly?
When setting the power, proceed as follows. Always start at level 1. Feel the effect of the ultrasound
waves on the specific body part. You may feel a slight tingling sensation when using it, but the
ultrasound waves themselves should not cause uncomfortable or even painful sensations. The main
purpose of using ultrasound wave technology is to be non-invasive and, most importantly, painless.
Therefore, pay extra attention that the set power does not cause you any discomfort. It is not
possible to determine exactly what level of power to apply to a particular part. Certainly do not pay,
the more power you use, the faster you will achieve the desired results in reducing subcutaneous fat.
The power setting should be handled very carefully. Higher power ultrasound waves will release
more energy in the fat tissue into the bloodstream, which your liver must then process. Do not rush
in anticipation of achieving the desired results. Even with a highly sophisticated type of treatment,
which ultrasound cavitation definitely is, there are certain processes in the human body that need to
be respected. Therefore, always start at intensity level 1. There may be situations where you never
use the full range of power. Allow more time between treatments of selected body parts - see the
passage TIME OF TREATMENT. Despite the gentle and non-invasive nature of the technology, your
health comes first.

Aesthetic body shaping device BeautyRelax BR-1950 CAVIMAX ULTIMATE User manual
20
TREATMENT TIME
The treatment time should not exceed 15 minutes. In the case of paired bodies divide this time in
half. i.e. 7,5 minutes for one thigh and 7,5 minutes for the other thigh.
A maximum of two parts can be treated at a time at a frequency of no more than once a week. The
same lot can be treated in 7 days at the earliest.
Example of a body treatment schedule
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
arms + calves leave leave thighs + calves leave leave leave
Why the days off?
When treating the body with an aesthetic device with ultrasonic cavitation function, it is absolutely
necessary to give the body some time to process the released energy in a natural way. Fat cells are
broken down into glycerol and free fatty acids. The glycerol serves as an energy source, while the
fatty acids are transferred to the liver where they are processed as normal fatty acids from food and
excreted out of the body naturally. Once this process is complete, the treatment can be safely
repeated.
CLEANING AND MAINTENANCE
The use of the device is always associated with the application of the
sonogel. Always ensure that the application head is cleaned after the
treatment is completed. If more than one person uses the device, the
surface of the applicator head should be disinfected. Ideally with an
alcohol spray solution. Do not use any aggressive cleaning agents.
Moisture must NEVER penetrate the device. Dry the applicator
thoroughly after cleaning. This will significantly prolong its service life.
Table of contents
Other BeautyRelax Massager manuals

BeautyRelax
BeautyRelax Kineticforce Portable User manual

BeautyRelax
BeautyRelax Headrelax Air BR-2797 User manual

BeautyRelax
BeautyRelax VACUFORM EXCLUSIVE User manual

BeautyRelax
BeautyRelax CAVIMAX BR-1410 User manual

BeautyRelax
BeautyRelax HYPERBLADE BR-1450 User manual

BeautyRelax
BeautyRelax ILIFT SMART BR-1350 User manual

BeautyRelax
BeautyRelax SHIATSUSOFT BR-2400 User manual

BeautyRelax
BeautyRelax EMSLIFT SMART BR-2620 User manual

BeautyRelax
BeautyRelax CELLUFORM OPTIMAL BR-2220 User manual

BeautyRelax
BeautyRelax Shape&Relax BR-2798 User manual