BeiJer KIRBY KRC User manual

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 28/01/22
Page 1 of 24
EN : 59292
KRC
Instruction Booklet

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 2 of 24
2
CONTENTS PAGE
Introduction ................................................................................................................................3
AImportant safety information and instructions................................................................4
PURPOSE- ..................................................................................................................................6
Standard Design Conditions......................................................................................................... 6
1. Lifting ......................................................................................................................................7
Tilt over to ground for twin coils unit ......................................................................................... 8
2. Unit Dimensions .....................................................................................................................9
2.1 KRC dimensional data............................................................................................................. 9
2.2 KRC dimensional diagrams..............................................................................................10
3. Electrical Connections........................................................................................................13
4. Lay out considerations ........................................................................................................22
5. Motor maintenance .............................................................................................................22
6. Start up..................................................................................................................................23
7. Cleaning ................................................................................................................................24

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 3 of 24
3
Introduction
The information contained in this booklet will provide the necessary safety information to
competently transport, lift, install commission and service the Remote Condenser (KRC) as per
Kirby requirements.
This manual should be kept in a dry place for a period of at least ten years, for possible
future reference. Read carefully and thoroughly all the information contained this
manual. Pay particular attention to the user instruction that appears and the heading
“Warning” or “Caution”. Failure to do so could result in damage to the machine, person
or property.
If you have any concerns regarding the performance and use of this unit, please contact Kirby.

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 4 of 24
4
A Important safety information and instructions – retain for future use.
Kirby is very safety conscious when designing and manufacturing these products, but it is
essential that the end user, installer or service personnel also exercise care when working with
or on the unit.
Warning
This indicates contents for which the possibility of human death or severe injury
in case of handling under disregard of this indication can be assumed.
Caution
This indicates contents for which the possibility of human injury or the
possibility of material damage in case of handling under disregard of this
indication can be assumed.
The Condenser unit:
Moving Machinery
KRC Units have components that may start up automatically. The KRC must have all electrical
items isolated before any service or repairs are carried out.
No Smoking
Kirby recommends No Smoking within a distance of 15 metres of the KRC Unit.
Warning – Electrical Hazard
A qualified Electrician must carry out all electrical work.
Always isolate the power to the KRC before checking, diagnosing, removing and replacing the
fan assembly units. Never work on any electrical item without isolating or disconnecting the
power supply.
Caution – Unit Pressurised
In the manufacturing of this product it is essential to pressurize and test the KRC. This unit may
have some pressure within. Please take care when unsealing the unit to fit the pipe and line
connections.
Caution – Refrigerant Type
The Condenser is designed to work effectively using fluorocarbon refrigerants. Under no
circumstances can Ammonia based gas, Hydrocarbon based gas, or CO2 gas, be used in this
product.
Refrigerant type: HCFC and HFC (refer to “Standard Conditions” for approved fluorocarbon
refrigerants)
For Water and Glycol applications please refer to your Kirby technical representative.
Caution – Sharp Edges

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 5 of 24
5
The Condenser is manufactured with sheet metal and in this process all care is taken to ensure
the edges are concealed. In some circumstances this cannot occur. Please take care when
accessing in or around the KRC.
Warning – Qualified Personnel
Condenser’s may only be installed, commissioned and serviced by qualified and trained
personnel .
Personal Protective Equipment
Kirby recommends as a secondary safety precaution that all personnel working in and around
the Condenser wear appropriate Personal Protective Equipment (PPE).
Lifting & Installation Precautions
Refer to page 6, 7 and 8.
Installation Instructions.
This product must be installed and maintained in accordance with the following:
•AS/NZS5149:2016 – Parts 3 & 4 (as applicable)
•AS4041:1998 – Pressure Piping
•Refrigerant Handling Code of Practice, Part 2
Useful information-
•Ozone Protection and Synthetic Greenhouse Gas Management Act 1989 (and amendments)
and Regulations 1995
•AIRAH DA12 – Energy Efficient Coolrooms
•AIRAH, DA19 – HVAC&R Maintenance
•CIBSE Code M - Commissioning Management
NOTE- There may be other applicable Codes and Standards that must be considered. It
is the responsibility of the Installer and Owner to ensure all requirements are considered
and complied with.

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 6 of 24
6
PURPOSE-
KRC remote condensers are standard OEM products of Kirby. They are intended to provide for
the condensation of fluorocarbon refrigerant for typical commercial sized refrigeration
applications, and are suitable for use in indoor or outdoor environments. They are not intended
for environments that may have harmful, corrosive or flammable atmospheres. ‘Marine’
environments are considered corrosive; please consult Kirby before installing in this
environment.
Standard Design Conditions
KRCxxx-xPH condensers are designed to operate with a maximum operating pressure of
3650kPag, with a maximum KTD of 20K, and a minimum of 5K (please refer to the relevant
technical data literature for more specific recommendations). Special circuiting may be needed
to achieve specific conditions outside of these limits- please refer to your Kirby representative.
Motors must NOT be subject to air-over-motor temperatures greater than allowed by the fan
manufacturer(s). Please refer to the relevant technical literature.
APPROVED REFRIGERANTS-
R404A/R448A/R449A/R134a/R513A/R450A and R410A are approved for use in all
KRCxxx-xPH models.
For more details, please refer to the relevant technical literature.
MAXIMUM WORKING PRESSURE-
KRCxxx-xPH models have a maximum working pressure of 3650kPag.
KRCxxx-xxH condensers cannot use Ammonia (NH3, R717), Carbon dioxide (R744), or
hydrocarbons, as refrigerant.
For special design requirements such as non standard conditions and/or fluid coolers (Glycol,
oil, etc), please inquire with your local representatives and/or Kirby local branches
MAXIMUM ALLOWABLE PRESSURE (PS/PSS)
UNIT DATA
PS
(kPag)
PSS
(kPag)
3650
n/a
Drawings
Drawings used in this manual are general in nature and may not accurately show the
appearance of actual units.

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 7 of 24
7
1. Lifting
Recommended lifting points and approx. weights
MODEL
NUMBER
APPROX WEIGHT kg
UN-
PACKED PACKED
KRC80-4PH 29 34
KRC107-4PH 34 39
KRC134-4PH 46 51
KRC137-6PH 51 56
KRC181-6PH 68 85
KRC254-6PH 93 110
KRC164-4PH 51 56
KRC213-4PH 68 85
KRC317-4PH 93 110
KRC389-6PH 129 153
KRC457-6PH 158 248
KRC574-6PH 186 276
MODEL
NUMBER
APPROX WEIGHT kg
UN-
PACKED PACKED
KRC693-6PH 208 328
KRC861-4PH 263 383

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 8 of 24
8
Tilt over to ground for twin coils unit vertical airflow only
MODEL
NUMBER
APPROX WEIGHT kg
UN-
PACKED PACKED
KRC778-6PH 271 311
KRC914-6PH 309 369
KRC1148-6PH 365 425
KRC1386-6PH 501 581
KRC1722-6PH 612 692
LIFT
& TILT
MAX . g= 120º
CONNECTED TO
APPROPRIATE
CRANE OR FORK-LIFT
"FORKLIFT"
LOWER
REMOVE
SKID FROM
UNIT
REMOVE
BRACING
FINAL RESTING POSITION

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 9 of 24
9
2. Unit Dimensions
2.1 KRC dimensional data
PRODUCT
NUMBER
FAN Ø X
QTY. A B C D E F G H J K L M N P W
KRC80-4PH 470 393
KRC107-4PH 570 520
KRC134-4PH
KRC137-6PH
KRC164-4PH
KRC181-6PH
KRC213-4PH
KRC254-6PH
KRC317-4PH
KRC389-6PH
KRC457-6PH
KRC574-6PH
KRC693-6PH
KRC861-6PH
KRC778-6PH
KRC914-6PH
KRC1148-6PH
KRC1386-6PH
KRC1722-6PH
Ø630 X 8 Refer Diagram C for dimensions
SINGLE CIRCUIT
Ø350 X 2
452 48 80
500
390
705
40 165 951 877 25 390 927
670 647
725
745
849 788
605 1020
62
Ø500 X 1
Ø500 X 2
766 54 75
220
1262 1165
38 605
1241
1581
2316
954 915 255
Ø630 X 2
1004 965 605
1050
220 1675 1505
Ø630 X 3
750
255 2408 2240
Ø630 X 4 840 80 80 1107 1065 610 18 440 3205 3003 44 610 3091
TWINCIRCUIT
Ø630 X 4
DiagramB 1929 1200 1933 695 1145 18 365 695
1505
44 695
2240
1581
Ø630 X 6 2316

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 10 of 24
10
2.2 KRC dimensional diagrams
KRC80 TO KRC861 (single coil)
VERTICAL AIR FLOW (Diagram A)
HORIZONTAL AIRFLOW (Diagram A)
Note : Both KRC137-6P and KRC164-4P are single fan Ø500 models

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 11 of 24
11
KRC718 TO KRC1148 (twin coil)
VERTICAL AIR FLOW (Diagram B)
HORIZONTAL AIRFLOW (Diagram B)

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 12 of 24
12
KRC1386 TO KR1722 (twin coil)
VERTICAL AIR FLOW (Diagram C)
HORIZONTAL AIRFLOW (Diagram C)

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 13 of 24
13
3. Electrical Connections
Warning Electrical 240Volt ±
±±
±10% (standard units)
or
Warning Electrical 415Volt ±
±±
±10% (optional units)
A qualified Electrician must carry out all electrical work.
For general wiring please refer page 15 to 21 for details.
Refer model number for corresponding “CL” drawing.
MOTORS WITH THERMAL OVERLOAD PROTECTION-
KRC remote condenser fans are all equipped with thermal overload motor protection.
Warning- Non-running fans may restart unexpectedly if the overload has been activated. Do
not assume a fan that is not running has been disconnected from the power supply. Always
check for the presence of live voltage before removing the junction box lid and/or performing
any work on the fans.
MOTORS WITH EXTERNALLY WIRED OVERLOADS-
350mm diameter single phase fans are equipped with internally wired overloads, which cut the
power supply to the motor directly.
500mm and 630mm single (and optional three phase) fans are equipped with externally wired
overloads. These overloads will only control power to the motor when wired in to an external
control circuit.
The wiring required depends on how many fans are present and whether the unit is a single or
twin coil model. Please refer to the following wiring schematic diagrams for details.
Failure to wire the externally connected overloads in a suitable manner may lead to
unnecessary failure of the motor and voiding of the unit warranty.
PLEASE REFER TO THE SERIAL PLATE OF THE CONDENSER AND/OR FANS TO
DETERMINE THE POWER SUPPLY OF THE FANS ON THE SUPPLIED UNIT, AND REFER
TO THE APPROPRIATE DIAGRAMS ON THE FOLLOWING PAGES.
FAN SPEED CONTROL-
Single and three phase AC fans may be controlled using a voltage reducing fan speed control
based on pressure sensing. Due to the large variety of controls available, only a few general
observations can be made.
Settings- Refer to the Recommended control settings on p14 for FVS setpoints, other settings
will be dependent on the individual controller selected.
Minimum voltage-
Fan manufacturers data should be referred to, however in general-
1 Ph- 130V (all fan types).
3 Ph- 230V (all fan types)

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 14 of 24
14
EC FANS-
EC fans are available on KRC condensers under the KP606- series options kits for 350mm,
500mm, and 630mm fan sizes.
The fans are 0-10V controlled, using a Saginaomiya XGE-4SE controller and high pressure
transducer mounted on the gas header.
Please refer to Technical Bulletin TB146 for details of the controller.
EC fans have built-in overload protection. If an EC fan does not start, please check the
temperature and allow to cool before diagnosing a faulty fan. The circumstances of the cut-out
should be investigated.
EC FAN KITS (0-10V with Saginomiya control)
Ø350 KRC
COND. KP606-7F KIT KRC 2X350MM EC SAGI EC FSC KRC80 KRC107
KRC134
Ø500 KRC
COND.
KP606-8F KIT KRC 1X500MM EC SAGI EC FSC KRC164-
KP606-9F KIT KRC 2X500MM EC SAGI EC FSC KRC213- KRC317-
Ø630 KRC
COND.
(1 COIL)
KP606-10F KIT KRC 2X630MM EC SAGI EC FSC KRC389-
KP606-11F KIT KRC/CENTURION 3X630MM EC SAGI EC FSC KRC457- KRC574-
KP606-12F KIT KRC/CENTURION 4X630MM EC SAGI EC FSC KRC693- KRC861-
Ø630 KRC
COND.
(2 COIL)
KP606-12F KIT KRC/CENTURION 4X630MM EC SAGI EC FSC KRC778-
KP606-13F KIT KRC/CENTURION 6X630MM EC SAGI EC FSC KRC914- KRC1148-
KP606-14F KIT KRC 8X630MM EC SAGI EC FSC KRC1386- KRC1722-
OPTIONAL EC FAN MODELS WILL HAVE A SERIAL PLATE WITH
MODEL NUM ER WITH
-
ECH SUFFIX UT ARE NOT SET
UP IN THE MANUFACTURING SYSTEM.
UNITS ARE ORDERED USING THE "CTO" SYSTEM.
Recommended control settings-
The Saginomiya control MUST NOT be used with R410A refrigerant.
Condenser must be sized to prevent pressure exceeding the design pressure, and the air over
motor temperature from exceeding the allowable value. Refer to technical literature CL250 and
CL287 for details.
For wiring details please see page 19.
Refrigerant R404A, R407F, R448A, R449A, R134a, R513A, R450A R410A
Setting (FVS) 19 bar (Factory setting) 13 bar
N/A
Adjusting range 10-25 bar
Proportional band
6 bar
Operational range 4-25 bar
Setting control approx. 1.5 bar / 22 psi : 1 turn = 360 °

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 15 of 24
15
Refer to CL263-1
IMPORTANT NOTE !
This wiring diagram is for general reference
only and does not imply any design
recommendation or approval by Kirby
HVAC&R.
All external wiring remains the sole
responsibility of the installer.

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 16 of 24
16
Refer to CL263-4
IMPORTANT NOTE !
This wiring diagram is for general reference
only and does not imply any design
recommendation or approval by Kirby
HVAC&R.
All external wiring remains the sole
responsibility of the installer.

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 17 of 24
17
Refer to CL263-5.
IMPORTANT NOTE !
This wiring diagram is for general reference only
and does not imply any design recommendation
or approval by Kirby HVAC&R.
All external wiring remains the sole
responsibility of the installer.

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 18 of 24
18
Refer to CL263-6
IMPORTANT NOTE !
This wiring diagram is for general reference
only and does not imply any design
recommendation or approval by Kirby
HVAC&R.
All external wiring remains the sole
responsibility of the installer.

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 19 of 24
19
Optional EC Fan wiring-
Refer to Schematic diagram MS804-63

KRC
Remote Condenser
Bulletin No. IM-033A
Issue: B
Date 29/01/22
Page 20 of 24
20
Optional 3 Phase fan wiring
Refer to CL263-2
IMPORTANT NOTE !
This wiring diagram is for general
reference only and does not imply any
design recommendation or approval by
Kirby HVAC&R.
All external wiring remains the sole
responsibility of the installer.
This manual suits for next models
19
Table of contents
Other BeiJer Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries DXK05ZTLA-WF user manual

Toshiba
Toshiba RAS-13SKHP-E Service manual

Frigidaire
Frigidaire FAK103J1V4 owner's guide

Samsung
Samsung AS09HM3N user manual

Panasonic
Panasonic CS-CZ25WKE Service manual

Mitsubishi Electric
Mitsubishi Electric Mr. Slim PUZ-M200YKA2.UK Service manual