Name plate
DRYPOINT® RA 1080-8800 5
Pos: 1 /Beko Technische D okumentation/Übersc hriften/1/Sic herheitshinweise @ 0\ mod_1183637609261_6.d oc @ 5365
1 Name plate
The name plate is on the back of the dryer and comprises all primary data of the device. Always refer to these data
when contacting the manufacturer or the sales department.
All guarantee claims will expire in the event that the name plate is modified or removed.
The dryer model printed on the nameplate includes one or more suffixes that specify one or more features of dryer.
Explanation of 1st suffix for power supply requirements :
1st SUFFIX DESCRIPTION OF FEATURE
none 3/400/50
-R 3/460/60
-S 3/230/60 (with internal autotransformer)
-F 3/380/60 (with internal autotransformer)
-T 3/690/60 (with internal autotransformer)
Explanation of 2nd suffix for cooling requirements :
2nd SUFFIX DESCRIPTION OF FEATURE
/ AC Air cooled
/ WC Fresh water cooled
/ SWC Sea water cooled, tube bundle condenser
/ TBH Fresh water cooled, tube bundle condenser
Explanation of (eventual) 3rd suffix for special feature :
3rd SUFFIX DESCRIPTION OF FEATURE
-TAC Anti corrosion treatment
-SP Special feature
-OF Dryer oil free
Examples : DP RA2200-R /AC DRYPOINT RA2200, 3/460/60, Air cooled
DP RA1800 /SWC DRYPOINT RA1800 3/400/50, Sea water cooled, tube bundle cond.
DP RA2200-T /WC DRYPOINT RA2200 3/690/60, Water cooled
2 Safety instructions
Pos: 2 /Beko Technische D okumentation/Globa le Texte/Allgemeiner Hinweis BM @ 0\mod_11836157373 13_6.doc @ 4004
Pos: 3 /Beko Technische D okumentation/Sic herheit/Hinweis Anlei tung BEKO @ 0\mod_1184147787 557_6.doc @ 5758
Please check whether or not these instructions correspond to the device type.
Please adhere to all advice given in these operating instructions. They include essential information
which must be observed during installation, operation and maintenance. Therefore, it must be ensured
that these operating instructions are read by the fitter and the responsible operator / certified skilled
personnel prior to installation, start-up and maintenance.
The operating instructions must be accessible at all times at the place of application of the DRYPOINT®
RA 1080-8800 compressed-air refrigeration dryer.
In addition to these operating instructions, local and national regulations need to be observed, where
required.
Ensure that operation of the DRYPOINT®RA 1080-8800 compressed-air refrigeration dryer only takes
place within the permissible limit values indicated on the name plate. Any deviation from these limit
values involves a risk for persons and for the material, and may result in malfunction or a breakdown.
After installing the device correctly and in accordance with the instructions in this manual, the dryer is
ready to operate, further settings are not required. Operation is fully automatic and maintenance is
limited to several examinations and cleaning measures which are described in the following chapters.
This manual must be available at all times for future reference and is a constituent part of the dryer.
If you have any queries regarding these installation and operating instructions, please contact BEKO
TECHNOLOGIES GMBH.