800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA
69
NFBUP, NFBUP-
S
, NFXUP, NFXUP-
S
On/Off, Sprin
g
Return, 24 to 240 VAC
T
orque min. 90 in-lb, for control of air dampers
A
pp
l
i
cat
i
o
n
F
or On/Off, fail-safe control of dampers in HVAC systems. Actuator sizing should be
d
one in accordance with the damper manufacturer’s specifications. Control is On/Off
f
rom an auxiliary contact, or a manual switch.
T
he actuator is mounted directl
y
to a dam
p
er shaft u
p
to 1.05” in diameter b
y
means
o
f its universal clamp. A crank arm and several mountin
g
brackets are available for
a
pplications where the actuator cannot be direct coupled to the damper shaft
.
O
peratio
n
T
he NFB and NFX series actuators provide true spring return operation for reliable fail-
s
afe application and positive close off on air ti
g
ht dampers. The sprin
g
return system
p
rovides constant tor
q
ue to the dam
p
er with, and without,
p
ower a
pp
lied to the
a
ctuator
.
T
he NFB and NFX series provides 95° of rotation and is provided with a graduated
p
osition indicator showin
g
0° to 95°.
T
he actuator ma
y
be stalled an
y
where in its normal rotation without the need of
m
ec
h
a
ni
ca
l
e
n
d
s
wit
c
h
es.
T
he NFBUP-
S
and NFXUP-
S
versions are provided with two built-in auxiliary switches.
T
hese SPDT switches provide safety interfacing or signaling, for example, for fan start
-
u
p. The switchin
g
f
unction at the
f
ail-sa
f
e position is
f
ixed at +10°, the other switch
function is ad
j
ustable between +10° to +90°. The NFBUP, NFBUP-
S
, NFXUP and
N
FXUP-S actuator is shipped at +5°
(
5° from full fail-safe
)
to provide automatic
c
ompression against damper gaskets for tight shut-off
.
Dimensions (Inches [mm])
K7-2 (supplied)
1/2" Centered
(Default)
3/4" Centered
(Field Selectable)
1.05" Centered
(Field Selectable)
WAFBNFBDi
m
Technical Data NFBUP, NFBUP-S, NFXUP, NFXUP-S
P
ower supp
l
y24...240 VA
C
-20%
/
+10%, 50
/
60 Hz
24...125 VDC ±10%
Power consum
p
tio
n
runnin
g
6 W
holdin
g
2.5 W
Trans
f
ormer sizin
g
6 VA @ 24 VAC
(
class 2 power source
)
6.5 VA @ 120 VA
C
9.5 VA @ 240 VA
C
El
ec
tri
ca
l
co
nn
ec
ti
on
NFBUP
..
.
3
ft, 18
G
A appliance cable, 1
/
2" conduit
connec
t
o
r
-S m
o
dels
:
Two 3 ft, 18 gauge appliance cables
w
ith 1/2” conduit connector
s
NFXUP..
.
3
ft [1m], 10 ft [3m] or 16 ft [5m] 18 G
A
a
pp
liance cable, with or without 1/2” conduit
connecto
r
-S m
o
dels
:
two 3
f
t
[
1m
]
, 10 ft
[
3m
]
or
16 ft [5m] appliance cables with or without 1
/
2"
conduit connectors
Overload protectio
n
electronic throu
g
hout 0 to 95° rotation
Contro
l
on/of
f
Tor
q
ue 90 in-lb
[
10 Nm
]
minimu
m
Direction o
f
rotatio
n
spr
i
ng
r
eversible with
C
W
/CC
W mounting
Mechanical an
g
le o
f
rotation 95°
(
ad
j
ustable with mechanical end stop,
3
5° to 95°
)
Runnin
g
tim
e
mo
t
o
r
< 7
5
seco
n
ds
s
pring 20 seconds
@
-4°F to 122°F
[
-20°
C
to 50°
C]
;
< 60 seconds @ -22°F
[
-30°C
]
P
os
iti
o
n in
d
i
ca
ti
on
v
isual indicator, 0° to 95
°
(
0° is full sprin
g
return position
)
Manual overrid
e
5
mm hex crank
(
³⁄
₁
₆
"
Allen
)
, supplied
Humidit
y
max. 95% RH non-condensin
g
A
m
bi
ent temperatur
e
-22°F to 122°F [-30°
C
to 50°
C
]
S
torage temperatur
e
-40°F to 176°F [-40°
C
to 80°
C
]
Housin
g
Nema 2, IP54, Enclosure Type
2
Housin
g
material zinc coated metal and plastic casin
g
A
gency
li
st
i
ngs
†
cULus acc. to UL60730-1A
/
-2-14,
C
AN/CSA E60730-1:02, CE acc. to
2004
/
108
/
E
C
& 2006
/
95
/
E
C
N
o
i
se
l
e
v
e
l<50dB(A) motor
@
75 second
s
≤62dB(A) spring return
S
ervicin
g
maintenance
f
ree
Q
uality standar
d
I
SO
9001
Wei
g
h
t
4.15 lbs
(
1.9 k
g)
, 4.4 lbs
(
2.0 k
g)
with switche
s
† Rated Impulse Voltage 4kV, Type of action 1.AA (1.AA.B for -
S
version),
C
ontrol Pollution Degree 3.
NFBUP-
S
, NFXUP-
S
Auxiliar
y
switche
s
2 x SPDT 3A
(
0.5A
)
@ 250 VAC, UL approve
d
one set at +10°, one ad
j
ustable 10° to 90°
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA
70
NFBUP
,
NFBUP-
S,
NFXUP
,
NFXUP-
S
O
n/Off, Sprin
g
Return, 24 to 240 VAC
Accessories
AV
8-2
5
S
haft extension
I
ND-AFB Damper position indicator
K
7-
2
Universal clamp for up to 1.05” dia jackshafts
K
H-AF
B
C
r
a
nk
a
rm
TF-
CC
U
S
C
onduit fitting
T
oo
l-
06
8
mm
a
n
d
1
0
mm wr
e
n
ch
Z
G
-1
00
Universal mountin
g
bracket
Z
G
-10
1
U
n
i
versa
l
mount
i
ng
b
rac
k
et
ZG-118 Mounting bracket for Barber Colma
n
®
MA 3../4.., Honeywell®
Mod III or IV or Johnso
n
®
Series 100 re
p
lacement or new crank
arm type installation
s
ZG-AF
B
Crank arm ada
p
tor kit
Z
G
-AFB118
C
rank arm adaptor kit
ZS-100 Weather shield (metal
)
Z
S
-150
W
eat
h
er s
hi
e
ld
(
po
l
ycar
b
onate
)
Z
S
-260
E
xplosion-proof housin
g
Z
S
-
300
N
EMA 4X housin
g
Note: When using NFBUP, NFBUP-S, NFXUP, NFXUP-S actuators, only use accessories listed on
this pa
g
e.
For actuator wiring information and diagrams, refer to Belimo Wiring Guide.
Typical Specification
On/Off sprin
g
return damper actuators shall be direct coupled type which require
n
o crank arm and linkage and be capable o
f
direct mounting to a jacksha
f
t up to a
1.05” diameter. The actuators must be designed so that they may be used
f
or either
clockwise or counterclockwise fail-safe o
p
eration. Actuators shall be
p
rotected
from overload at all an
g
les of rotation. If required, two SPDT auxiliary switch shall
b
e provided havin
g
the capability of one bein
g
ad
j
ustable. Actuators with auxiliary
s
witches must be constructed to meet the requirements
f
or Double Insulation so
an electrical ground is not required to meet agency listings. Actuators shall be
cULus A
pp
roved and have a 5
y
ear warrant
y
, and be manufactured under ISO 9001
International Qualit
y
Control Standards. Actuators shall be as manufactured b
y
Belimo.
Wiring Diagrams
1
Provide overload protection and disconnect as required
.
2
C
AUTI
ON
Equipment Damage!
Actuators may be connected in parallel
.
Power consum
p
tion and in
p
ut im
p
edance must be observed.
3
No ground connection is required
.
4
For end
p
osition indication, interlock control, fan startu
p
, etc., NFBUP-S and
NFXUP-
S
incorporates two built-in auxiliary switches: 2 x
S
PDT, 3A
(
0.5A
)
@250 VAC, UL Approved, one switch is fixed at +10°, one is adjustable 10°
to
90°.
Meets cULus requirements without the need of an electrical ground con
-
n
ec
ti
o
n
.
WARNING
Live Electrical Components!
G
Durin
g
installation, testin
g
, servicin
g
and troubleshootin
g
of this product, it may be
necessar
y
to work with live electrical com
p
onents. Have a
q
ualified licensed electrician or other
individual who has been properly trained in handling live electrical components per
f
orm these
tasks. Failure to
f
ollow all electrical sa
f
et
y
p
recautions when ex
p
osed to live electrical com
p
o
-
nents cou
ld
resu
l
t
i
n
d
eat
h
or ser
i
ous
i
n
j
ury
.
NFBUP, NFBUP-S
NFXUP, NFBUP-S
W066_NFB
(
X
)
UP
On/Off wiring for NFBUP, NFXUP
Wht
Blk
NFBUP-S
NFXUP-S
W067_NFB
(
X
)
UP-S
Auxiliary Switches for NFBUP-S, NFXUP-
S
M40024 - 05/10 - Sub
j
ect to chan
g
e. © Belimo Aircontrols
(
USA
)
, Inc.

This manual suits for next models

3

Other Belimo Controllers manuals

Belimo LF24-SR US User manual

Belimo

Belimo LF24-SR US User manual

Belimo LMB series Guide

Belimo

Belimo LMB series Guide

Belimo VAV-Compact D3 User manual

Belimo

Belimo VAV-Compact D3 User manual

Belimo SGVL/G2 User manual

Belimo

Belimo SGVL/G2 User manual

Belimo SY 3-T Series User manual

Belimo

Belimo SY 3-T Series User manual

Belimo LMB24-MFT User manual

Belimo

Belimo LMB24-MFT User manual

Belimo SY U24-SR Series Quick start guide

Belimo

Belimo SY U24-SR Series Quick start guide

Belimo CMB24-3 User manual

Belimo

Belimo CMB24-3 User manual

Belimo SM24A-S Instruction Manual

Belimo

Belimo SM24A-S Instruction Manual

Belimo AF24-LIN US User manual

Belimo

Belimo AF24-LIN US User manual

Belimo NMQB24-MFT User manual

Belimo

Belimo NMQB24-MFT User manual

Belimo LRX24-SR User manual

Belimo

Belimo LRX24-SR User manual

Belimo PRCA-S2-T Instruction Manual

Belimo

Belimo PRCA-S2-T Instruction Manual

Belimo CMU Series Instruction manual

Belimo

Belimo CMU Series Instruction manual

Belimo LMQB24-MFT Instruction manual

Belimo

Belimo LMQB24-MFT Instruction manual

Belimo AFB Series User manual

Belimo

Belimo AFB Series User manual

Belimo GMX24-3-X1 User manual

Belimo

Belimo GMX24-3-X1 User manual

Belimo AFX24LON User manual

Belimo

Belimo AFX24LON User manual

Belimo LRB24-3 User manual

Belimo

Belimo LRB24-3 User manual

Belimo T24-DM1 User manual

Belimo

Belimo T24-DM1 User manual

Belimo LMQB24-1 User manual

Belimo

Belimo LMQB24-1 User manual

Belimo FGVL Series User manual

Belimo

Belimo FGVL Series User manual

Belimo LF-2 Series User manual

Belimo

Belimo LF-2 Series User manual

Belimo LF24-SR-E US User manual

Belimo

Belimo LF24-SR-E US User manual

Popular Controllers manuals by other brands

RKC INSTRUMENT CB100 Series Communication instruction manual

RKC INSTRUMENT

RKC INSTRUMENT CB100 Series Communication instruction manual

dji Phantom 2 Vision + user manual

dji

dji Phantom 2 Vision + user manual

Newport CONEX-PP Series GUI Manual

Newport

Newport CONEX-PP Series GUI Manual

ESBE CRK200 Series manual

ESBE

ESBE CRK200 Series manual

Buderus AM10 Installation and operating instructions

Buderus

Buderus AM10 Installation and operating instructions

Hiltron security TWIN quick start guide

Hiltron security

Hiltron security TWIN quick start guide

Mitsubishi Electric MELSEC Q Series Programming manual

Mitsubishi Electric

Mitsubishi Electric MELSEC Q Series Programming manual

BFI Automation CFC 4000L Original operating instructions

BFI Automation

BFI Automation CFC 4000L Original operating instructions

Emerson Tescom 44-6800 Series Operation & service manual

Emerson

Emerson Tescom 44-6800 Series Operation & service manual

Omron NX Series user manual

Omron

Omron NX Series user manual

OLYS SNC50 user manual

OLYS

OLYS SNC50 user manual

DMXking.com eDMX4 MAX DIN user manual

DMXking.com

DMXking.com eDMX4 MAX DIN user manual

McQuay MicroTech III RAH Operation and maintenance manual

McQuay

McQuay MicroTech III RAH Operation and maintenance manual

Mircom TX3 Series Installation quick reference

Mircom

Mircom TX3 Series Installation quick reference

RLE Technologies SeaHawk 10K quick start guide

RLE Technologies

RLE Technologies SeaHawk 10K quick start guide

Omron E5DC instruction manual

Omron

Omron E5DC instruction manual

Eltako FSR61LN-230V manual

Eltako

Eltako FSR61LN-230V manual

Emerson Fisher 4660 instruction manual

Emerson

Emerson Fisher 4660 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.