manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Best
  6. •
  7. Accessories
  8. •
  9. Best PIK33 User manual

Best PIK33 User manual

SPECIFICATION SHEET
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
80F 99044051B
Especially designed to be installed in custom hood
for use over residential commercial-style cooking
surfaces.
FEATURES
•Cabinet mount _ custom application
•Widths: 33’’, 45’’
•Halogen lighting (33’’_2 x 50 watt; 45’’_3 x 50 watt GU10)
Lamps included
• Slidecontrols:Lighting,on-off,innitespeed
•Easily accessible, dishwasher-safe stainless steel
bafelters
•Heat Sentry™ turns blower ON to HIGH speed when
excess heat is detected
OPTIONS
•Custom hood liners (L33 or L45 Series):
Widths - 36’’, 42’’, 48’’, 54” and 60’’
Adjustable depth - see liner spec. sheet for details
Stainless Steel construction - protects custom hood
base
and wipes clean easily
•Ambient light panel (ALP Series) for L Series custom
hood liners (Halogen lighting: 36’’ and 42’’_2 x 50 watt;
48”, 54” and 60” _3 x 50 watt GU10) Lamps included
•Backsplash (RMP Series):
Widths - 36”, 42”, 48”, 60”
Stainless Steel construction - protects back wall
and wipes clean easily
•WCPI Remote control: With Stainless Steel faceplate,
 totanydécor.
INSERT SPECIFICATIONS
120 VAC, 60 Hz
Amps (without blower) 0.8 (PIK33), 1.3 (PIK45)
Mount insert so bottom of custom hood is 24’’ to 30’’
above cooking surface.
Best Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
Best Drummondville, QC, Canada www.BestRangeHoods.com 866-737-7770
16
36", 42", 48", 60"
”
4
”
14
1
4
”
18
”
10
”
HA0011
4 1/2''
6 3/8''
HC0010
HK0076A
Custom Hood Liner
L33 or L45 Series
Backsplash
RMP Series
WCPI Remote Control
HB0032
Ambient Light Panel
ALP Series
HA0027A
4”
Adjustable depth
(See liner spec
sheet for details)
Fits custom hood nominal
width 36”, 42”, 48”, 54” or 60
”
PIK SERIES
INSERT
PIK MOUNTING
Size of the cut-out
NOTE: The 3 1/2’’ notch must be cut only if the WCPI
optional wall control will be installed.
HH0040A
1 1/2”
HD0093A
17 1/16''
16 3/8''
32 1/2'' or 44 1/2''
3 1/2''
2 1/4'' min.
NOTE: If optional L series liner is used, refer to installation
instructions for size and location of the cut-out.
Suggested Custom Hood Internal Framework
HL0065
- 3 -
RMP Series Backsplash
(Stainless Steel wall
covering with warming
shelves. Optional)
L3336S, L3342S, L4548S
L4554S or L4560S
Custom Hood Liner (optional)
Model 415
7” Round
adjustable elbow
(optional)
8” Round
adjustable elbow
(optional)
Model 412
transition
(3¼” x 10” to 7”)
Adapter and damper 3¼’’ x 10’’
(supplied with P5 and P8 blowers)
Adapter and damper 3¼’’ x 14’’
(supplied with P8 blower)
Model P5
single-blower
(500 cfm)
PIK33 OR PIK45
INSERT
- PIK33 AND PIK45 INSERT SYSTEM -
INTERIOR BLOWERS
Flow deviator
(supplied with P5 and P8 blowers)
Model 647
(7” Round
wall cap)
Model 634 or 644
(roof cap)
Model 643
(8” Round
wall cap)
8” Round
standard
duct
Model 407
(7” Round x 24’’
section)
7” Round
metal flexible
duct (optional)
8” Round
metal flexible duct
(optional)
Model 413
transition
(3¼” x 10” to 8”)
Model 459
transition
(3¼” x 14” to 8”)
Model P8
dual-blower (900 cfm)
NOTE: The dual blower P8 must be
installed with 8’’ round duct. If it
is impossible to connect the dual
blower P8 to a 8’’ round duct,
use a 7’’ round duct. In that
case, the blower performance
will be decreased by 25%.
Rough-in kit
(supplied with P5 and P8 blowers)
ALP36, ALP42,
ALP48, ALP54 or ALP60
Ambient light panel (optional)
WCPI
Wall control
(Optional)
- 4 -
HL0066
RMP Series Backsplash
(Stainless Steel wall
covering with warming
shelves. Optional)
L3336S, L3342S, L4548S
L4554S or L4560S
Custom Hood Liner (optional)
Model 418
10” Round
adjustable elbow
(optional)
Model ILB3 (280 cfm)
in-line blower
(includes one 8” to 10”
round transition)
PIK33 OR PIK45
INSERT
- PIK33 AND PIK45 INSERT SYSTEM -
IN-LINE AND EXTERIOR BLOWERS
Model EB6 (600 cfm)
or EB9 (900 cfm)
exterior blower
Model EB12 (1200 cfm)
or EB15 (1500 cfm)
exterior blower
Model 441
(10” Round
wall cap)
Model 437
(High capacity roof cap)
Model 441
(10” Round wall cap)
Model 421
(10” Round vert.
in-line damper)
Recommended
for use with
exterior blowers
Model 410
(10” Rd duct
- 2 ft. sections)
10” Round
metal flexible duct
(optional)
In-line and exterior blower
rough-in kit (included with ILB3,
ILB6, ILB9, ILB11, EB6, EB9,
EB12 and EB15 blowers)
ALP36, ALP42,
ALP48, ALP54 or ALP60
Ambient light panel (optional)
WCPI
Wall control
(optional)
Model ILB6 (600 cfm)
in-line blower
(includes two 4½” x 18½”
to 10’’ round transitions)
Model ILB9 (800 cfm)
or ILB11 (1100 cfm)
in-line blower
(includes two 8” x 12” to
10’’ round transitions)
MODEL PIK33 WITH P8 BLOWER (Vertical Outlet)
PIK SERIES INSERTS
BLOWER DUCTING
POSITIONS
HB0032


3/4’’
3 1/4’’
16 1/8’’
7 5/8’’
7/8’’
14’’
9 1/8’’
7/8’’ dia.
8’’ round
transition
HK0031A
MODEL PIK33 WITH P5 BLOWER (Vertical Outlet)


3/4’’
3 1/4’’
16 1/8’’
7 5/8’’
7/8’’
10’’
11 1/8’’
7/8’’ dia.
7’’ or 8’’
round transition
HK0030A
MODEL PIK33 WITH EB6, EB9, EB12 OR EB15
BLOWER (Vertical Outlet)


5 1/4’’
16 1/8’’
9 5/8’’ dia.
7/8’’ dia.
1 11/16’’
6 11/16’’
HK0029
MODEL PIK45 WITH P8 BLOWER (Vertical Outlet)
MODEL PIK45 WITH P5 BLOWER (Vertical Outlet)
MODEL PIK45 WITH EB6, EB9, EB12 OR EB15
BLOWER (Vertical Outlet)


3 1/4’’
22 1/8’’
13 5/8’’
7/8’’
3/4’’ 15 1/8’’
14’’
7/8’’ dia.
8’’ round
transition
HK0034A


3 1/4’’
22 1/8’’
13 5/8’’
7/8’’
3/4’’ 17 1/8’’
10’’
7/8’’ dia.
7’’ or 8’’
round transition
HK0033A


5 1/4’’
22 1/8’’ 12 11/16’’
1 11/16’’
9 5/8’’ dia.
7/8’’ dia.
HK0032
Top view Top view
Top view Top view
Top view Top view

Other manuals for PIK33

2

This manual suits for next models

2

Other Best Accessories manuals

Best L2936 User manual

Best

Best L2936 User manual

Best BestReach BRR46030 User manual

Best

Best BestReach BRR46030 User manual

Best BRB 230 OS 2838 User manual

Best

Best BRB 230 OS 2838 User manual

Popular Accessories manuals by other brands

Rehau NEA SMART 2.0 Quick install

Rehau

Rehau NEA SMART 2.0 Quick install

IFM EIO404 operating instructions

IFM

IFM EIO404 operating instructions

Advance acoustic SUCCESS 5 manual

Advance acoustic

Advance acoustic SUCCESS 5 manual

Hobo RXW-THC-B Series manual

Hobo

Hobo RXW-THC-B Series manual

SOMFY 2401219 manual

SOMFY

SOMFY 2401219 manual

Health Zenith 5872 manual

Health Zenith

Health Zenith 5872 manual

CORA CS1030 user guide

CORA

CORA CS1030 user guide

Merrytek MC601V manual

Merrytek

Merrytek MC601V manual

MCPO Smart Socket user guide

MCPO

MCPO Smart Socket user guide

Hoyt Formula Series owner's manual

Hoyt

Hoyt Formula Series owner's manual

Hama MagPower 5 operating instructions

Hama

Hama MagPower 5 operating instructions

Tektronix TPR1000 user manual

Tektronix

Tektronix TPR1000 user manual

Crane EE-8000 manual

Crane

Crane EE-8000 manual

Varta SLIM 12000 quick start guide

Varta

Varta SLIM 12000 quick start guide

Gorgy Timing 92261 Series quick start guide

Gorgy Timing

Gorgy Timing 92261 Series quick start guide

Halo 5500 user manual

Halo

Halo 5500 user manual

ABB SensyTemp TSP Commissioning instructions

ABB

ABB SensyTemp TSP Commissioning instructions

Trust MAIN SOCKET SWITCH AC-3000 manual

Trust

Trust MAIN SOCKET SWITCH AC-3000 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.