Beyerdynamic Quinta CU Configuration guide

beyerdynamic GmbH & Co. KG
Theresienstr. 8 | 74072 Heilbronn – Germany
Tel. +49 (0) 71 31 / 617 - 0 | Fax +49 (0) 71 31 / 617 - 204
For further distributors worldwide, please go to www.beyerdynamic.com
Non-contractual illustrations. Contents subject to change without notice. E2 / Quinta CU (01.13)
Quinta CU
Digital Control Unit
Order # 723.924
FEATURES
• DSSS modulation to ensure high immunity from interference in
the frequency range of 2.4 / 5.2 and 5.8 GHz
• HD - High Definition audio mode provides an audio bandwidth
of 24 KHz and a sampling rate of 48 KHz
• HQ - High Quality of service mode for a user-optimised
transmitting and receiving performance in difficult
environments in terms of radio transmission
• AVB (Audio Video Bridging) input and output for digital signal
transmission in building networks - compliant to the IEEE 801.1
standards
• True diversity antenna technology ensures highest transmission
and reception reliability
• Digital 128-bit encryption and additional 24-bit PIN code
protection
• Automatic recognition of interferences in all frequency ranges
• Silent change to an interference-free frequency range -
automatic or manual according to the EN 300328 ETSI
• The control unit can manage up to 150 microphone units
• 4 audio up-streams for up to 4 microphone signals
• 2 audio down-streams for loudspeaker transmission and
headphone output
• NOM - Number of open Microphones function allows the
allocation of up to 4 microphone units simultaneously
• Processor-controlled and automatic audio channel allocation of
the microphone units
• Different operating modes:
Manual – each participant can turn the microphone on and off;
Voice Activation – the microphone is turned on when someone
speaks into it;
Override – when a microphone unit is activated, the one that
was activated before will be turned off;
Push-To-Talk – as long as the participant speaks into the micro-
phone, he/she must press the microphone button.
• Integrated DSP for flexible audio routing
• Zoning – the output channel allocation of individual micro-
phone units can be divided into 4 different audio zones
analogue or digital via AVB
• With the Mix-Minus function the system can be integrated into
tele- and video conferences
• Fully parametrical 4-band equalizer for microphone unit loud-
speakers and master output
• NOM attenuation for the master output and individual audio
zone outputs
• Analogue audio input for external signals or digital via AVB
• System control and configuration via RS 232, USB or Ethernet;
connection to a media control system is possible
• Integrated web server for platform independent system
configuration via Smartphone, tablet PC or laptop/PC
• Individual audio channels can be monitored via adjustable
headphone connections with a jog/shuttle button on the front
• OLED display for indication of the system state and operation
of all parameters
• Connections on the front panel:
1x headphone output via 1/4" jack (6.35mm);
1 x USB Type B
• Connections on the rear panel:
1x bal. audio master output via 3-pin XLR;
1x bal. audio master output via Phoenix terminal strip;
1x unbal. audio master output via RCA;
4x bal. audio zone outputs via Phoenix terminal strip,
1x digital AVB (Audio Video Bridging) via RJ45;
1x unbal. audio input via RCA;
1x RS232 via 9-pin Sub-D;
1x TCP/IP via RJ45;
2x antenna connections N(HF)
• 19" desktop housing, 1 U
• Dimensions (W x H x D) 440 x 44 x 239 mm
[17.32" x 1.73" x 9.41"]
• Supplied with two angled rod antennas
1 of 4

Quinta CU
beyerdynamic GmbH & Co. KG
Theresienstr. 8 | 74072 Heilbronn – Germany
Tel. +49 (0) 71 31 / 617 - 0 | Fax +49 (0) 71 31 / 617 - 204
For further distributors worldwide, please go to www.beyerdynamic.com
Non-contractual illustrations. Contents subject to change without notice. E2 / Quinta CU (01.13)
2 of 4
ARCHITECT’SSPECIFICATIONS
The control unit shall be the core of a digital wireless discussion
system. The DSSS modulation shall ensure high immunity from
interference in the frequency range of 2.4 / 5.2 and 5.8 GHz. The
HD- High Definition audio mode shall provide an audio bandwidth
of 24 KHz and a sampling rate of 48 KHz. The HQ- High Quality of
service mode shall be used for a user-optimised transmitting and
receiving performance in difficult environments in terms of radio
transmission. The AVB (Audio Video Bridging) input and output for
digital signal transmission in building networks shall be compliant to
the IEEE 801.1 standards. The true diversity antenna technology
shall ensure highest transmission reliability. The digital 128-bit
encryption shall include an additional 24-bit PIN code. There shall be
an automatic recognition of interferences in all frequency ranges.
The silent change to an interference-free frequency range shall be
automatic or manual according to the EN 300328 ETSI. The control
unit shall manage up to 150 microphone units. There shall be
4 audio up-streams for up to 4 microphone signals. There shall be
2 audio down-streams for loudspeaker transmission and headphone
output. The NOM - Number of open Microphones function shall
allow the allocation of up to 4 microphone units simultaneously.
The audio channel allocation of the microphone units shall be
processor-controlled and automatic. The control unit shall feature
different operating modes: Manual – each participant can turn the
microphone on and off; Voice Activation – the microphone is turned
on when someone speaks into it; Override – when a microphone
unit is activated, the one that was activated before will be turned
off; Push-To-Talk – as long as the participant speaks into the micro-
phone, he/she must press the microphone button. For flexible audio
routing there shall be an integrated DSP. Zoning – the output
channel allocation of individual microphone units shall be divided
into 4 different audio zones analogue or digital via AVB. With the
Mix-Minus function the system shall be integrated into tele and
video conferences. The control unit shall feature a fully parametrical
4-band equalizer for microphone unit loudspeakers and master
output, a NOM attenuation for the master output and individual
audio zone outputs as well as an analogue audio input for external
signals or digital via AVB. The system control and configuration shall
be done via RS 232, USB or Ethernet. The connection to a media
control system shall be possible. An integrated web service shall be
available for platform independent system configuration via
Smartphone, tablet PC or laptop/PC. The individual audio channels
shall be monitored via adjustable headphone connections with a
jog/shuttle button on the front. The OLED display shall indicate the
state and operation of all parameters. The connection on the front
shall be a plug-in type: 1x headphone output via 1/4" jack
(6.35mm); 1 x USB Type B. The connection on the rear shall be a
plug-in type: 1x bal. audio master output via 3-pin XLR; 1x bal. audio
master output via Phoenix terminal strip; 1x unbal. audio master
output via RCA; 4x bal. audio zone outputs via Phoenix terminal
strip, 1x digital AVB (Audio Video Bridging) via RJ45; 1x unbal. audio
input via RCA; 1x RS232 via 9-pin Sub-D; 1x TCP/IP via RJ45;
2x antenna connections N(HF). The dimensions of the 19" desktop
housing with 1 U shall be (WxHxD) 440 x 44 x 239 mm
[17.32" x 1.73" x 9.41"]. The delivery shall include 2 angled rod
antennas.
Manufacturer: beyerdynamic
Type: Quinta CU
DESCRIPTION
The Quinta CU control unit is used to control about 150 wireless
microphone units with loudspeakers. Depending on the settings
and selected operating mode up to 4 microphone units can be
turned on simultaneously (e.g. 3 delegate and 1 chairman micro-
phone unit). There is a constant status inquiry, monitoring or
control due to the data connection to the microphone units.
Individual microphone units can be activated via the RS 232 serial
interface. The complete discussion system can be switched off via a
control command or by pressing the “Stand-by” button on the
front. The 4 LEDs on the front indicate the assigned transmission
channels of the microphones. For maximum security the control unit
can be protected with a PIN code accepting only microphone units
that have the correct PIN code. In addition to this, the radio
transmission is digitally encrypted.
The Quinta system meets the regulations of the European Tele-
communications Standards Institute (ETSI) and can be integrated
inot existing or new building computer networks that comply
IEEE 802.1 IT standard (AVB). For a safe wireless transmission there
are three frequency bands available: 2.4 / 5.2 / 5.8 GHz. The
switching of the channels is either automatically or manually.
The protection against unauthorised listening is guaranteed by using
128-bit encryption and a 24-bit PIN-code.
The integrated Web server allows configuring the control unit with
a Smartphone, tablet PC or PC via USB, LAN, WLAN.
The system can be connected to a media control system via the
RS 232 interface. This allows a particularly convenient operation and
provides different status indicators e.g. the battery status. Furthermore,
the Quinta system can be integrated into tele and video conferences.

Quinta CU
beyerdynamic GmbH & Co. KG
Theresienstr. 8 | 74072 Heilbronn – Germany
Tel. +49 (0) 71 31 / 617 - 0 | Fax +49 (0) 71 31 / 617 - 204
For further distributors worldwide, please go to www.beyerdynamic.com
Non-contractual illustrations. Contents subject to change without notice. E2 / Quinta CU (01.13)
3 of 4
TECHNICAL SPECIFICATIONS
General
Frequency range. . . . . . . . . . . . . . . . 2400 – 2483.5 MHz
5150 – 5250 MHz
5725 – 5875 MHz
Modulation . . . . . . . . . . . . . . . . . . . DSSS (Direct Sequence
Spread Spectrum) and
QPSK/BPSK (Quadrature/
Binary Phase Shift Keying)
digital signal processing acc.
to own standard
Max. number of audio streams. . . . . 4 useable channels per
system
Signal-to-noise ratio . . . . . . . . . . . . . 80 dB typ., (unweighted
signal-to-noise ratio)
Range between microphone units
and control unit . . . . . . . . . . . . . . . . > 100 m [109.36 yds]
Power supply . . . . . . . . . . . . . . . . . . 100 – 240 V AC 50/60 Hz
Approval . . . . . . . . . . . . . . . . . . . . . world-wide
AVB
Transmission and reception
of audio data . . . . . . . . . . . . . . . . . . acc. to IEC 61883-6
Format of the audio data . . . . . . . . . AM824
Stream ID Quinta CU . . . . . . . . . . . . Bit 63 – 16 / MAC address
Bit 15 – 0 / X
Quinta CU Control Unit
Frequency response . . . . . . . . . . . . . 70 Hz – 22 kHz (-3 dB)
Operation mode. . . . . . . . . . . . . . . . Diversity (receiver), separate
for each channel
Antenna connection. . . . . . . . . . . . . 2 N-connectors (female)
Transmitting power . . . . . . . . . . . . . max. 20 dBm per channel
and region (average, duty
cycle ≤30%)*
Connections
Serial control port. . . . . . . . . . . . . . . RS 232, USB
Ethernet port . . . . . . . . . . . . . . . . . . LAN, TCP/IP standard
Master output balanced . . . . . . . . . . 1 x XLR, 1 x 3-pin Phoenix
terminal strip, max. +6 dBu,
level adjustable via software
(range ±15 dB)
Master output unbalanced . . . . . . . . RCA, max. +2.2 dBu,
level adjustable via software
(range ±15 dB)
Audio outputs, single channels. . . . . 4 x 3-pin Phoenix terminal
strip, max. +6 dBu, level
adjustable via software
(range 0 ... -50 dB)
Input balanced . . . . . . . . . . . . . . . . . 1 x 3-pin Phoenix terminal
strip, max. +6 dBu, input
adjustable via software
(range 0 ... -50 dB)
Power supply . . . . . . . . . . . . . . . . . . 100 – 240 V AC
50/60 Hz 70 – 150 mA
Fuse . . . . . . . . . . . . . . . . . . . . . . . . . 2 x AL 0.5 A (slow blow)
Power consumption . . . . . . . . . . . . . 10 VA
Temperature range . . . . . . . . . . . . . . +10° – +40 °C
[+50 °F – +104 °F
(at < 90% humidity)
Indication . . . . . . . . . . . . . . . . . . . . . 4 channel LEDs (red/white)
and Power LED (red/white)
Min. depth of Rack. . . . . . . . . . . . . . 380 mm
Dimensions (W x H x D) . . . . . . . . . . 19", 1HU
(440 x 44 x 239 mm)
[17.32" x 1.73" x 9.41"]
Weight. . . . . . . . . . . . . . . . . . . . . . . 3.2 kg [7.05 lbs]
AVB interface:
MAC address . . . . . . . . . . . . . . . . . . 00:22:BB:00:FF:FF
Stream Suffix . . . . . . . . . . . . . . . . . . 00:00
Stream ID . . . . . . . . . . . . . . . . . . . . . 00:22:BB:00:FF:FF:00:00
Number of channels . . . . . . . . . . . . . 4
Audio format . . . . . . . . . . . . . . . . . . IEC 61883-6/AM824 with
24-bit / 48 kHz
IP configuration . . . . . . . . . . . . . . . . DHCP
*The transmitter power can differ from this value due to specific
regulations in various countries.
SUPPLIED ACCESSORIES
1 Power cable
1 USB cable
6 Phoenix terminal strips, 3-pin
2 CA Q11 antennas
1 Unlocking tool
Quinta Software Control and
configuration software . . . . . . Order # 723.991
OPTIONAL ACCESSORIES
CA Q 13 Planar antenna, 2.4 - 5.8 GHz . . . . . . Order # 724.408
CA Q 14 Omnidirectional antenna for
remote installation. . . . . . . . . . . . . . . Order # 723.894
CA Q 30 System coaxial cable Ecoflex,
sold per metre . . . . . . . . . . . . . . . . . . Order # 724.440
CA Q 31 System coaxial cable Ecoflex, 10 m . . Order # 724.416
CA Q 32 System coaxial cable Ecoflex, 20 m . . Order # 724.424

Quinta CU
beyerdynamic GmbH & Co. KG
Theresienstr. 8 | 74072 Heilbronn – Germany
Tel. +49 (0) 71 31 / 617 - 0 | Fax +49 (0) 71 31 / 617 - 204
For further distributors worldwide, please go to www.beyerdynamic.com
Non-contractual illustrations. Contents subject to change without notice. E2 / Quinta CU (01.13)
4 of 4
DIMENSIONS
Other manuals for Quinta CU
1
Other Beyerdynamic Control Unit manuals
Popular Control Unit manuals by other brands

Kamstrup
Kamstrup HC-003-56 installation guide

XJTAG
XJTAG XJAccelerator user guide

Sun Microsystems
Sun Microsystems Dual Port 4x IB Host Channel Adapter... user guide

Grundfos
Grundfos CIU 501 Installation and operating instructions

Festo
Festo HSW-x-AP Series operating instructions

Flowstar
Flowstar CT5-1 Installation and operating manual

RHEINTACHO
RHEINTACHO Stroboscope Control Unit operating instructions

Uponor
Uponor A3030003 instruction sheet

ADLINK Technology
ADLINK Technology USB-1210 quick start guide

Aeotec
Aeotec Micro Switch G2 installation instructions

Ross
Ross HDBH Series operating instructions

ADTRAN
ADTRAN Modem-16 Module user manual