BIOCAIR BC-65 PRO II User manual

INSTRUCTION MANUAL
Dry-Mist Disinfection Machine
www.biocair.com.sg
1 year warranty included register at

Model Name/Number: BC-65™Pro II Dry-Mist Disinfection Machine
Product Dimension: 150mm x 154mm x 274mm
Product Weight (without water): 0.70 kg
Voltage: 100-240V~50/60Hz
Power Consumption: 32W
Water Tank Capacity: 1.8L
Maximum Mist Volume: 250ml/h
SPECIFICATIONS:
COMPONENTS
1 Nozzle
2 Water tank
3 Base
4 Indicator light
5 Mist volume knob
1
2
453

INSTRUCTION
This appliance can be used by children aged
from 8 years and above and persons with
reduced physical, sensory or mental capabili-
ties or lack of experience and knowledge if
they have been given supervision or instruc-
tion concerning use of the appliance in a safe
way and understand the hazards involved.
Cleaning and user maintenance shall not be
made by children without supervision.
Unplug the appliance during filling and clean-
ing.
It is recommended to use BioCair Air Purifying
Solution with distilled water. Water tempera-
ture should not be higher than 40℃ .
If the supply cord is damaged, it must be
replaced by the JCS Biotech service centre or a
qualified person in order to avoid an electrical
hazard.
Children should be supervised by a parent or
guardian, ensuring that they do not play with
the appliance.

Using the latest ultrasonic technology, BC-65™Pro II converts BC-65™ Air Purifying
Solution into a fine and disinfecting mist of 1-5µm, diffusing them into the air. Suitable
for use by everyone, BC-65™Pro II works continuously for up to 6 hours (max mist
volume). When used with BioCair® Air Purifying Solution, 99.999% of airborne and
surface harmful pathogens are eliminated, reducing the risk of illness and diseases
caused by harmful pathogens. Frequent usage of BC-65™Pro II to diffuse BioCair® Air
Purifying Solution can disinfect our indoor environment; improve our health and our
overall well-being.
INTRODUCTION
Using the concept of vibrating ultrasonic waves, BC-65™Pro II converts BC-65™ Air
Purifying Solution into a fine and disinfecting dry-mist of 1-5 µm-sized particles,
producing large amounts of mist, diffusing them into the air.
HOW IT WORKS
FEATURES
Long service life
Soft glow light
Power-saving
Cool & refreshing mist
Zero noise level
Eco-friendly product
Adjustable mist level

A. The ideal temperature range for using BC-65™Pro II is from 0ºC to 40ºC.
• If you use the BC-65™Pro II in a cold room, do not increase the room temperature
immediately. It is recommended that you increase the room temperature to a
normal level gradually.
• If the BC-65™Pro II is brought into a warm environment from a cold place where
it was stored initially, wait for half an hour before use. There might be water
droplets on the mechanical parts due to condensation. Using it under such
condition may result in malfunction.
B. It is recommended to use BioCair® Air Purifying Solution with distilled
water.Water temperature should not be higher than 40ºC.
C. Remove water tank from the base, open lid by turning it anticlockwise, fill with
BC-65™Air Purifying Solution, ensuring that the silicon washer is fitted in place and
then close the water lid by turning it clockwise.
D. Connect to power supply,power on by turning the mist intensity knob.
E. When cleaning or moving the unit, please turn it off and remove the water tank.
Shaking it may lead to overflow of water into the base, affecting its functionality.
INSTRUCTIONS FOR USE
The LED indicator light is green during normal operation. It will turn to red when the
water level runs low, reminding you to fill up the water tank.
SAFETY FEATURE

TRANSDUCER
a. The water tank should be cleaned regularly, most preferably once every 3 days with
clean water and a soft brush.
b. Excess Air Purifying Solution left in water tank should be diffused within 7 days.
WATER TANK
CLEANING AND MAINTENANCE
a. If the water groove and water level detector have minerals sediments too, please
use a soft cloth to clean, and then wash the water groove with clean water.
b. Do not immerse the base in water and make sure that no water enters the vent.
BASE
As time passes, there might be mineral residue from tap water left on the object
surface, transducer, water groove and ground, which affects the functionality of the
humidifier. In order to clean the transducer, please
• Make sure to unplug before cleaning.
• Use clean water to clean the transducer.
• Use a soft cloth to clean the surface of the transducer. Do not use hard tools
to scratch its surface.
• Do not use soap or other alkaline substances to clean the transducer.
The original packaging is ideal to store the unit. Please store in a dust-free and
moisture-free environment. Make sure the parts are cleaned properly and ensure it is
completely dry before storage.
STORAGE

A. Additives like perfume, essential oils, etc. are not recommended for BC-65™Pro II
use. It is prohibited to add alkaline substances into the water tank.
B. When in operation,do not touch the water in the groove or other parts,lest an
unexpected electric shock may happen.
C. Do not direct the spray nozzle at children,furniture and walls, etc.Adjust it to face an
empty space instead.
D. Do not face BC-65™Pro II towards any electrical appliances, sockets and material
surfaces that are sensitive to water droplets.
E. Do not leave it on unstable surfaces.When working, do not tilt or
overturn it
.
F. In case of abnormal noise or smell, please turn it off and unplug it from the power
socket immediately.
G. Keep it away from sunlight and direct heat sources.
H. Do not attempt to repair or replace parts by yourself; send it to the JCS Biotech
service centre for help. Unauthorized modifications or restructuring of BC-65™Pro II
may lead to inconveniences or dangers.
I. If not in use, please unplug and store it properly.
J. If the supply cord is damaged, it must be replaced by the JCS Biotech service centre
or a qualified person in order to avoid an electrical hazard.
K. Children should be supervised by a parent or guardian, ensuring that they do not
play with the appliance.
L. Do not fill water tank with abrasive or corrosive chemicals.
M. Do not operate the BC-65™Pro II with wet hands.
N. Do not soak the base in water. If it is soaked in water, unplug the adaptor and
contact the JCS Biotech service centre immediately.
O. Switch off the power supply before unplugging BC-65™Pro II.
P. Do not connect or disconnect the adaptor from the electrical outlet with wet hands
to avoid an electrical shock.
Q. Do not place the adaptor under BC-65™Pro II or any heavy items.
CAUTION !

TROUBLESHOOTING
No breeze,
no mist
• No power supply.
• Power switch is off.
• Water level of the groove is too high.
• Leakage of water tank.
• Connect to power supply.
• Turn on the power switch.
• Lower the water level by
reducing water in the groove.
• Tighten the water lid.
Breeze, but
no mist
• No water in the water tank.
• Water level detector is not in
the right position.
• The temperature of the unit is
too low.
• Fill water into the water tank.
• Re-mount the water
level detector.
• Place unit in a room for half
an hour before use.
Low spurting
of mist
• Mist intensity controller is on
the minimum side.
• Water tank and the base are
not secure.
• Fan does not work properly.
• Adjust the controller.
• Ensure water tank and the
base are secure.
• Enlist professional help to
check the fan inside the base.
Noise • Resonance caused by too little
water in the water tank.
• Resonance caused by unstable
surfaces.
• Add more water into the
water tank.
• Place unit on stable surfaces.
Low mist
intensity
• Too much water in the water groove
• Mist intensity knob is on the
minimum side.
• Mineral sediments on the
transducer.
• The water is too cold.
• The water is unclean.
• Empty the water in the
groove and place the
water tank again.
• Adjust the knob.
• Clean the transducer.
• Use water of room
temperature.
• Clean the water tank and
refill it with clean water.
Odd mist smell • Water in the tank is kept
for too long.
• Clean the water tank
and refill it.
ISSUE POSSIBLE REASON(S) SOLUTION(S)

For technical and service support,
please contact:
JCS Biotech Pte Ltd
2 Woodlands Sector 1
#01-07 Woodlands Spectrum 1
Singapore 738068
Email: sales@BioCair.com.sg
www.biocair.com.sg
Table of contents
Other BIOCAIR Air Cleaner manuals
Popular Air Cleaner manuals by other brands

Bryant
Bryant 901KAX Installation, Start-Up and Service Instructions

clair
clair BF2025 instruction manual

Goodman
Goodman ASAS-10ASC Installation, operation and service instructions

Rensair
Rensair Q01B instruction manual

Airphx
Airphx CID 75k Quick reference guide

AirMaid
AirMaid 500 C operating instructions