BIOCAIR Ultimate II User manual

Use with
BC-65™
Air Purifying
Solution
Ultimate II - 5.5L Dry-Mist
Instruction Manual
1 year warranty included
Register at www.biocair.com.sg

The Ultimate II – 5.5L Dy-Mist Disinfection Machine disinfects areas up
to 65sqm. When used with BioCair®BC-65™Air Purifying Solution, the
Ultimate II machine will generate dry-mist that eliminates 99.999% of
airborne and surfaces germs within 60-seconds of contact, keeping your
air disinfected and germ-free.
Suitable for use in homes, offices and any indoor environments.
GENERAL INTRODUCTION
Product Name: Ultimate II – 5.5L Dry-Mist Disinfection Machine
Voltage: 100 – 240V
Frequency: 50Hz
Power: 32W
Tank Capacity: 5.5L
Noise: < 35db
Net Weight: 2.5kg
Gross Weight: 3kg
Product Size: 235 x 235 x 685 mm
Box Size: 410 x 265 x 460 mm
Material: ABS
Mist Output: 250 – 500mL/h
PRODUCT SPECIFICATIONS
BioCair Aerial Disinfection machines carry a one-year warranty from the
date of purchase, a dated proof of purchase is required for any warranty
claim. The warranty should be registered within 1 month after the
purchase date. The warranty does not apply to wear and tear that results
from normal product usage. The warranty does not cover Ultimate II
machine that has been used with essential oil, accidental damage,
neglect, abuse or misuse, any alternation of the machine or repair
service by an unauthorised party. Failure to follow the operating
instructions provided with the product will void the warranty.
The warranty and product instructions are subject to change without
notice.
PRODUCT WARRANTY
11

1
2
3
4
55
56
COMPONENTS
SYMBOLS ON THE CONTROL PANEL
1 Nozzle
2 Lid
3 Water Tank
4 LED Display and Control Panel
5 Base
6 Power Adapter
Power Switch
Mist volume adjustment button
Humidity volume adjustment button
Timer
Night Light
2

Power
Switch
Mist
Level
Adjust
Humidity
Level
Adjust
Timer
Night
Light
REMOTE CONTROLLER
• This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved.
• Cleaning and user maintenance shall not be made by children without
supervision.
• Unplug the appliance during filling and cleaning.
• It is recommended to use BioCair®BC-65™Air Purifying Solution with distilled
water. Water temperature should not be higher than 40ºC.
• If the supply cord is damaged, it must be replaced by JCS Biotech service
centre or a qualified person in order to avoid an electrical hazard.
• Children should be supervised by a parent or guardian, ensuring that they do
not play with the appliance.
INSTRUCTIONS
3

Using the concept of vibrating ultrasonic waves,
BioCair®
Ultimate II-5.5L
Dry-Mist Disinfection Machine converts BioCair
BC-65™
Air Purifying Solution
into a fine, dry-mist that travels throughout a room to eliminate 99.999% aerial
and surface bacteria.
2. Open the lid
3. Mix 1: 1 ratio of
BC-65 Air Purifying
Solution and distilled
water.
4. Pour the mixture
into the Ultimate II and
close the lid.
1. Place the machine
on a flat surface.
BC-65
Air Purifying
Solution
HOW IT WORKS
DIRECTIONS FOR USE
Large Water
Tank
Up to
65sqm
Multiple
Mist Flow
Setting
Available
with remote
Control
Dry-Mist Night LightUp to 12hrs Touch
Screen
FEATURES
5.5L
4
Distilled
Water

Important notice: Use only with BioCair BC-65 Air Purifying Solution.
Using essential oils or other liquids/ substances can lead to lasting
machine damage, including preventing the machine from operating.
INSTRUCTIONS FOR USE
SAFETY FEATURE
BioCair Ultimate II-5.5L Dry-mist Disinfection Machine comes with a safety
feature that shuts off automatically when the water level runs low. An icon will
be shown on the display, reminding you to refill the water tank.
A. The ideal temperature range for using BioCair®Ultimate II – 5.5L Dry-Mist
Disinfection Machine is from 0°C to 40°C.
• If you are using the Ultimate II – 5.5L Disinfection Machine in a cold room,
do not increase the room temperature immediately. It is recommended
that you increase the room temperature to a normal gradually.
• If the Ultimate II – 5.5L Disinfection Machine is brought into a warm
environment from a cold place where it was stored initially, wait for half an
hour before use. There might be water droplets on the mechanical parts
due to condensation. Using it under such condition may results in malfunction.
B. Open the lid of the water tank and fill the tank with BioCair BC-65™Air
Purifying Solution and Distilled water (1:1 ration). Close the lid of the water
tank once done.
C. Connect the power adaptor. Touch the button after hearing a beep sound
and the Ultimate II will be switched on.
D. Touch the button, where the mist volume can be adjusted with
signifying the volume. Recommended to set the mist volume at
E. Touch the button to set the timer from 1 to 12 hours. Recommended to
1 hour of disinfection per day.
F. If the water level runs low, a icon will be shown on the display.
5

a. The water tank should be cleaned regularly, most preferably once every 3 days
with clean water and a soft cloth.
b. Excess BioCair®BC-65™Air Purifying Solution left in water tank should be
diffused within 4 days.
WATER TANK
a. If the water groove and water level detector have mineral sediments too, please
use the soft cloth to clean, and then wash the water groove with clean water.
b. Do not immerse the base in water and make sure that no water went into
the vents.
BASE
As time passes, there might be mineral residue from the distilled water left on
the object surface, transducer, water groove and ground, which affects the
functionality of the machine. In order to clean the transducer, please:
TRANSDUCER
CLEANING AND MAINTENANCE
STORAGE
The original packaging is ideal to store the unit. Please store in a dust-free
and moisture-free environment. Make sure the parts are cleaned properly
and ensure it is completely dry before storage.
This marking indicates that this product should not be disposed with other
household wastes throughout the EU. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return
your used device, please use the return and collection systems or contact the
retailer where the product was purchased.
• Use clean water to clean the transducer.
• Use a soft cloth to clean the surface of the transducer, do not use hard
tools to scratch its surface.
• Do not use soap or other alkaline substances to clean the transducer.
6

A. When in operation, do not touch the water in the groove or other parts,
lest an unexpected electric shock may happen.
B. Do not direct the spray nozzle at people, furniture and walls etc. Adjust it
to face an empty space instead.
C. Do not face BioCair®Ultimate II-5.5L Dry-Mist Disinfection Machine towards
any electrical appliances, sockets and material surfaces that are sensitive to
water droplets.
D. Do not leave it on unstable surfaces. When working do not tilt or
overturn it.
E. In case of abnormal noise or smell, please turn it off and unplug it from the
power socket immediately.
F. Keep it away from sunlight and direct heat sources.
G. Do not attempt to repair or replace parts by yourself; send it to the JCS
Biotech service centre for help. Unauthorized modifications or
restructuring of Ultimate II Machine may lead to inconvenience or dangers.
H. If not in use, please unplug and store it properly.
I. Do not fill water tank with abrasive or corrosive chemicals.
J. Do not operate the Ultimate II Disinfection Machine with wet hands.
K. Do not soak the base in water. If it is soak in water, unplug the adaptor and
contact JCS Biotech service centre immediately.
L. Switch off the power supply before unplugging the Ultimate II Disinfection
Machine.
M. Do not connect or disconnect the adaptor from the electrical outlet with
wet hands to avoid an electrical shock.
N. Do not place the adaptor under the Ultimate II Machine or any heavy items.
CAUTION
7

ISSUE
No breeze,
no mist
Breeze,
but no mist
Odd mist
smell
Low mist
intensity
Low spurting
of mist
Noise
•No power supply.
•Power switch is off.
•Water level of the groove is too high.
•Leakage of water tank.
•Humidity setting is too low.
• No water in the water tank.
• Water level detector is not in
the right position.
• The temperature of the unit
is too low.
• Too much water in the water groove.
• Mist intensity is low.
• Mineral sediments on the
transducer.
• The water is too cold.
• The water is unclean.
• Mist intensity is low.
• Water tank and the base
are not secured.
• Fan does not work properly.
• Resonance caused by too little
water in the water tank.
• Resonance caused by unstable
surfaces.
• Add more water into the water
tank.
• Place unit on stable surfaces.
• Adjust the mist intensity.
• Ensure water tank and the base
are secured.
• Enlist professional help to check
the fan inside the base.
• Empty the water in the groove
and place the water tank again.
• Adjust the mist intensity.
• Clean the transducer.
• Use water of room temperature.
• Clean the water tank and refill
it with clean water.
• Water in the tank is kept
for too long.
• Clean the water tank
and refill it with clean water.
• Fill water into the water tank.
• Re-mount the water level
detector.
• Place unit in a room for half
an hour before use.
• Connect to power supply.
• Turn on the power switch.
• Lower the water level by
reducing water in the groove.
• Tighten the water lid.
TROUBLESHOOTING
8
POSSIBLE REASON(S) SOLUTION(S)

+65 6602 9483
www.biocair.com.sg BioCair
For technical and service support,
please contact:
JCS BIOTECH PTE LTD
2 Woodlands Sector 1
#01-07 Woodlands Spectrum 1
Singapore 738068