Bioland 3002 User manual

PORTABLE WRIST
BLOOD PRESSURE MONITOR
Model: 3002
INSTRUCTION MANUAL
611-30020-000
VER 1.0, 10/2005

TABLE OF CONTENTS
Introduction ..........................................................................2
Notes on Safety ....................................................................2
AFew Words About Blood Pressure.....................................4
Precautions Before Use .......................................................7
Main Unit ..............................................................................8
Accessories Parts................................................................9
Features of the Product .......................................................9
Battery Installation/Replacement .........................................9
Time and Date of System Setup ........................................11
How to Apply the Wrist Cuff ...............................................11
AFew Suggestions Before Blood Pressure Measurement...13
Wrist Monitor QuickReference Guide ...............................13
How to Take a Measurement .............................................14
Recalling Record ................................................................16
How to Maintain and Store the Unit ...................................16
How to Prevent a Malfunction ............................................17
Specifications.....................................................................18
Troubleshooting ................................................................19
INTRODUCTION
ThankyouforpurchasingthePortableWristBloodPressure
Monitor.Thisremarkableinstrumentisidealforpeoplewho
frequentlymonitortheirown bloodpressurebecauseit'sso
compactandeasytouse.Thereisnobulkyarmcuff,justasmall,
pre-formedwristcuffthatiseasytoapply
.withthepushofa
buttontheportablewristmonitormeasuresyourbloodpressure
andpulseanddisplaysthereadingonacleardigitalpanel.
Perfectforquick,easyreadingsathome,atwork,almost
anywhere!
ThePortableWristMonitorusestheoscillometricmethodof
bloodpressuremeasurement.Thismeansthemonitordetects
yourblood's movementthroughthearteryinyourwristand
convertsthemovementsintoa digitalreading.An oscillometric
monitordoesnotneedastethoscopesothemonitorissimpleto
useandmeasurementsareeasytoobtain.
Clinicalresearchhasprovenadirectrelationshipbetweenblood
pressureinthewristandbloodpressureinthearm.Changesin
wristbloodpressurereflectchangesinarmbloodpressure
becausethearteriesinthewristandthearmconnect.Frequently
measuringthebloodpressureinyourwristwillprovideyouand
yourdoctorwithanaccurateindicationofchangesinyouractual
bloodpressure.
Theproductcomplieswiththeelectromagneticcompatibility
requirementofEN60601-1-2andsafetystandardsof60601-1as
specifiedinEEC directive93/42/EEC.
-1- -2-

The icon indicates something that is compulsory
(What must always be observed).
Matters involving actual compulsory actions are
indicated by text or pictures in or near .
The lefticon refers to "general compulsion".
The icon indicates prohibitions
(what you should not do).
Matters involving actual prohibitions are indicated
by text or pictures in or near . The left icon
refers to "general prohibition".
*
The warning signs and sample icons shown here are
listed for your safe and correct use of the unit, so as
to prevent injuries or damage to the monitor.
*
The icons and meanings are as follow.
Please read this instruction manual thoroughly before
using the Portable Wrist Blood Pressure Monitor.
For
specific information on your own blood pressure,
CONTACT
YOUR DOCTOR.
NOTES ON SAFETY
Examples of signs
Type BF Applied part
Attention and read before use
-3-
Caution
Self-diagnosis of measured results and treatment
are dangerous. Please follow the instructions of
your doctor.
Self-diagnosis may worsen the disease.
Do not use the unit for infants or person who cannot
express one's intention.
May cause accident or trouble.
Do not use the unit for purpose other than
measuring blood pressure.
May cause accident or trouble.
Do not use cellular phone near the unit.
The main unit may operate erroneously.
Do not disassemble, repair, or remodel the main
unit or the cuff of the blood pressure monitor.
Will cause the unit to function erroneously.
-4-

Heart Contracts
(Pressure Increases)
Heart Relaxes
(Pressure Decreases)
Requests from Manufacturer
Used batteries may leak and damage the main unit.
Please observe the following points.
*
If you are not going to use the unit for a long period of
time (approximately three
months or more), remove
the batteries.
*
Replace worn batteries with the same battery type as
specified in the specifications.
*
Do not insert the batteries with their polarities in the
wrong direction.
Do not use force to bend or pull the cuff.
Do not knock or drop the main unit.
Do not inflate the wrist cuff when it is not wrapped on the wrist.
Always use the specified accessories in the manual,
the use of other parts not approved by the manufacturer
may cause faults or injuries.
For service information like circuit diagram, parts list etc.,
please contact the dealer.
A FEW WORDS ABOUT BLOOD PRESSURE
Blood pressure is the force exerted
on the walls of your blood vessels as
blood flows through them.
Your heart is like a pump. When it contracts,
or beats, it sends a surge of blood through
the blood vessels and pressure increases.
This is called your systolic pressure.
When your heart relaxes between beats,
your blood pressure decreases. This is
called your diastolic pressure.
-5--6-
When a doctor takes your blood pressure,
he
or she measures both your systolic and
diastolic pressures and records them as
numbers. For example, if your blood pressure
reading is 126/76 (126 over 76), your systolic
is 126 and your diastolic is 76. The numbers
are calculated in millimetres of mercury and
recorded as 126/76 mm Hg.
Systolic
(Upper Number)
Diastolic
(Lower Number)
Thesetwo numbersprovideimportantinformationaboutyour
health. The more difficult it is for your blood to flow through
your blood vessels, the higher both numbers willbe. When
bloodpressureisconsistentlyabovenormalitiscalled
hypertension (High blood pressure).
Ournew PortableWristBloodPressureMonitorautomatically
measuresyoursystolicanddiastolicbloodpressureforyou,
thendisplaystheresultsoneasy-to-readdigitalpanel!
People with a condition that causes circulatory problems
(diabetes,
kidney disease, arteriosclerosis, or poor peripheral
circulation) may get lower readings with wrist type monitor
than with a blood pressure monitor that isused on the upper

Fluctuation Within a Day
(Example: 35-year old male)
0
5 pm
Time
11pm 5 am 11am 5 pm
50
100
150
200
250
300
Dinner Sleeping Lunch
Systolic
Blood pressure
Diastolic
Blood pressure
Blood Pressure (mm Hg)
Breakfast
arm.Pleaseconsultyour physiciantodetermineifyour
wrist blood pressure accurately reflects your actual blood
pressure.
Your blood pressure changes constantly.Blood pressure
fluctuates
fromday to dayandminute tominute according
toyourbody'sneeds.Forexample,whenyouareexercising
orangryyourbloodpressureincreases, but when you are
relaxing orsleeping
yourbloodpressuredecreases.These
fluctuationsare completely
normal.Thisportablewrist
bloodpressuremonitoris especially helpfulwhentracking
changesinyourbloodpressurebecauseittravels
anywhere and takes just seconds to use.
-7--8-
FACTORS THAT MAYCAUSETHE BLOOD PRESSURE TO FLUCTUATE
*Breathing *Exercise *Mental stress *Worries * Environmental
and/ortemperature
change*Eating*Urinationandbowelmovement
*Talking *Taking a bath *Drinking
alcohol
*
Smoking, etc.
Note: One or two readings will not provide a true indication of
your normal blood pressure. It is very important to take
regular,dailymeasurementsandtokeepaccuraterecords.
Inpartnershipwithyourdoctor,anaccuraterecordofyour
blood pressure over a period of time can be a valuable
aidindiagnosingandpreventingpotentialhealthproblems.
TheWorldHealthOrganisation(WHO) developedthefollowing
Blood Pressure Classification. This classification, however,
is only ageneral guidelinebecause bloodpressurevaries from
person to person according to age, weight, and health status.
CONSULTYOURPHYSICIANTODETERMINE YOUR
NORMALBLOODPRESSURE.
95
mm Hg
Hypertension
Borderline
Normal
140 160 mm Hg
90
Diastolic
WHO Blood Pressure Classification
Normal
Borderline
Hypertension
Systolic (mmHg)
less than 139
140to 159
more than 160
Diastolic (mmHg)
less than 89
90 to 94
more than 95
Systolic

1. SET Button
2. ON/OFF Button
3. Button to start measurement
or memory recall
4. Clear digital display
5. Date and time display
6. Systolic blood pressure
7. Diastolic blood pressure
8. Pulse/min.
9. Wrist cuff .
10. Battery cover
Note: There is not an universally accepted definition of
hypotension
(low blood pressure), but a systolic
pressurebelow99mmHgis usually regardedas
hypotension.
PRECAUTIONS BEFORE USE
1. Do not confuse self-monitoring with self-diagnoses.
2. If you are taking medication, consult with your doctor
todeterminethemostappropriatetimetomeasureyour
bloodpressure.NEVER changeaprescribedmedication
without first consulting with your doctor.
3. Forpeoplewithirregularorunstableperipheralcirculation
problemsdue
todiabetes,liverdisease,hardeningofthe
arteries,etc.,theremaybefluctuationinbloodpressure
values measured at the upper arm versus at the wrist.
4. Thisdevice isdesigned for adults to use. If use this
deviceonachildpatient,oldpeopleortoddlers,consult
with your physician or measurewith relative aid.
Bloodpressure measurementsshouldonlybe
interpreted by a health professional who is familiar
with your medical history.
5. Measurementsmaybeimpairedifthisdeviceisusednear
televisions,microwave ovens,X-ray mobile phone
equipmentorotherdeviceswithstrongelectricalfields.
T
oprevent
suchinterference,usethemeteratasufficient
distancefromsuchdevicesorturnthemoff.
6.Thisdeviceisnotsuitablefordiseasediagnoses,urgent
treatment,continuous monitoringduring medical
emergenciesoroperations.
7. Before using, should wash your hands.
8. Ifthereistoomuchpressureoryoufeeluncomfortable,
pleasepress"POWER"buttonimmediatelyforquickdeflation.
-9- -10-
MAIN UNIT
9
8
5
4
1
23
7
6
10

ACCESSORIES PARTS
Storage Box
2 "AAA" alkaline Batteries
SYMBOLS ON DISPLAY
FEATURES OF THE PRODUCT
6. Compact size for easy carry.
7. Easy to use, press a button to automatically measure,
record measurement values and time in the memory.
8. Automatically turns off (within 2.5 minutes) to save power.
BATTERY INSTALLATION/REPLACEMENT
1.Slide the battery cover off as shown in figure.
-12-
-11-
2. Install 2 "AAA" size alkaline batteries
into battery compartment make sure in
correct polarity direction (as indicated
in the bottom of battery compartment).
3. Replace the battery cover.
1. Uses the fuzzy-logic measurement.
2. Memory can store 128 measurements.
3. Easy to use buttons.
4. Large and clear display.
5. Fan-shaped wrist cuff that is easy to wrap.
Note:
*
If the Low Battery Indicator appears on the display,
replace both batteries.
Long-life alkaline batteries
are recommended.
*
Remove the batteries if the
monitor
will not be used for
an extended period of time.
HEART BEAT
INFLATION
DEFLATION
mmHg
Kpa
PUI.SE
-min
SYS
DIA
SYSTOLIC
MEMORY
DIASTOLIC
LOW BATTERY
PULSE UNIT
ATTENTION OF ERROR
MONTH/DATE HOUR/MINUTE
VALUE OF SYSTOLIC
VALUE OF DIASTOLIC
UNIT OF PRESSURE
VALUE OF
PULSE PER MINUTE
+-
+-

-13-
* When the battery icon flashing, the device will turn off
automatically. Please replace with new battery immediately
HOW TO REMOVE OLD BATTERIES:
Pull the ribbon outward to uninstall batteries.
1. Press and holdthe " " setbuttonfor2secondstoenterthe
setting mode whenthe unit is on.
2. Pressthe"" buttontoadjusttheYear,thenpressthe""
setbuttonagaintosaveyoursettingandentertheMonth
setting mode.
3. Pressthe""buttontoadjusttheMonth.Followingthesame
steps to adjust Date/Hour/Minute until setting completed.
HOW TO SET DATE & TIME
PUI.SE
-min
SYS
DIA
1/2" - 3/4 "
(1~2cm)
Wrist Joint
HOW TO APPLYTHE WRIST CUFF
1. Put off your watch and any jewel from your left hand.
2. Hold your left wrist with your palm facing up, apply the
cuff so that the display of monitor is in easy to view.
3.Thecuff'sedgeshouldbeapproximately 1/2 to 3/4 inch
(1~2cm) from your palm.
-14-
4. Wrap the cuffsnuglyaround your wrist.,the top and
bottom edges of the cuffshould be tightened evenly
around your wrist and lower arm.
5. Whenthecuffispositionedcorrectly,secureitin
placebypressingthevelcromaterialfirmlyagainstthe
each otherto fix device on your wrist.
*
With the use of two alkaline "AAA" batteries, you can
measure
approximately 200 times at room temperature
of 22OC and inflating to around 170mmHg once a day.
But the included batteries only for test purpose, it may
not last as specified long period.
Disposal of empty battery to the authorized
collecting party subject to the regulation of
each individual territory.
+-
+-

-15-
6. Sit in a chair with your feet flat on the floor and place your left
arm on a table with your palm facing upward.
The cuff should
be at the same
level asyour heart.
Note: Your heart is located slightly below your armpit.
7. Ifthe cuff isnot atthe same level as yourheart or ifyou cannot
keep your
armcompletelystillthroughout themeasuring,use
thestore box or other soft objectto support your arm.
1. Avoid eating, smoking, and exercising for at least 30 minutes
before taking
a measurement. Also rest for at least 15 minutes
before taking a reading.
2. Stress raises blood pressure. Avoid taking measurements
during stressful
times.
3. The cuff should be applied on your left wrist.
A FEW SUGGESTIONS BEFORE
BLOOD PRESSURE MEASUREMENT
4.
Measurement should be taken in a quiet place and you should
be relaxed
,seated position. Rest your left arm on a table so
that the cuff is at the same height level as your heart.
5. Remain still and do not talk during the measurement.
6. Keep a record of your blood pressure and pulse for your
doctor. Remember,
a single measurement does not
provide an accurate indication of your true blood
pressure. You need to take and record several
measurements over a period of time. Try to measure
your blood pressure at the same time each day for
consistency. Blood pressure measurements fluctuate
considerably.
7. Wait 5-10 minutes between successive measurements.
Waiting allows the engorged blood vessels to return
to normal. You may require more rest time depending
on your individual physical conditions.
-16-

PUI.SE
-min
SYS
DIA
-17-
HOW TO TAKE A MEASUREMENT
Please read "A few suggestions before blood pressure
measurement" and "How to apply the wrist cuff" before
taking a measurement.
1.Taking measurements while sitting down
1) Place your elbow on a table.
2) Using the store box or other object as a support position
your wrist at heart level.
3) Relax your hand and keep palm facing up.
4) Press the " " button, all icons appear in two seconds
on LCD, then display "0" or last measurement data.
5) Press the " " button to start measurement. The
pressure cuff in the strap will automatically inflate.
when the value that LCD display increase to around
150~200mmHg, then start to deflation until
measurement completes, and display results on LCD.
M
PUI.SE
-min
SYS
DIA
PUI.SE
-min
SYS
DIA
PUI.SE
-min
SYS
DIA
6) After measurement the screen will display systolic,
diastolic, and pulse/min value. Meanwhile, Data it
will auto matic ally. store into memory.
7) Press " " button to turn off the unit.
Note: *The unit may store 128 measurement records,
if more than 128 records, it will only store
latest 128 records.
Note:
*
The value measured will be too low if you hold your
hand higher than
your heart lever or too high if you
hold your hand lower than your heart lever.
* Do not bend your wrist inward.
* The unit may store 128 measurement records
, if
more than 128 records, it will only store latest 128
memories.
* During measurement avoid speaking and body/hand
shaking which may affect the accuracy of record.
*
During measurement process, If you want to stop,
just
press the power button to stop.
-18-
mmHg
Kpa
PUI.SE
-min
SYS
DIA

1. Press and hold the " /M " button for 2 seconds to enter the
momery mode and display the last memory when the unit is on.
3. When the unit is in momery mode, press both " " and " /M"
buttons for more than 2 seconds to delete the all records.
-19-
RECALLING RECORD
HOW TO MAINTAIN AND STORE THE UNIT
1. Use a dry , soft cloth to clean the unit. If necessary, use a cloth
lightly dampened
with tap water.
2. Do not use alcohol, benzene, thinner
or other harsh chemicals
to clean
the device or cuff.
3. Before measuring please wash your hands.
Do not wash or wet the wrist cuff.
4. Store the unit in places far from
direct sunlight, high humidity
or dust.
5. Fold the pressure cuff and put
the unit into the store box.
Note: When the unit will not be used for a long time, be
sure to remove the batteries. Otherwise, the
batteries may leak and damage the unit.
HOW TO PREVENT A MALFUNCTION
1. Do not drop the device and avoid sudden jars or shocks.
2. Do not insert any objects into any holes.
3. Do not attempt to disassemble the unit.
4. Do not crush the pressure cuff.
5. If the unit has been stored at below 0 oC, put it in a warm
place for about 30 minutes before using it. Otherwise,
may get wrong measurement result.
-20-
2. Press the " /M " or " " button to review the data in memory.
/M
/M

Measuring Method:
Indication:
Measuring Range:
Accuracy:
Inflation
Deflation:
Memory:
Power Source:
Battery Life:
Working Temp. & Humidity:
Storage Temp. & Humidity:
Outside Dimensions:
Weight:
Accessories:
Oscillometric System
Digital LCD Display
Pressure: 0~300 mmHg;
Pressure: ±3 mmHg; Pulse ±5%
Electric Pump Inflation
Pressure Release Valve
128 Memories
1.5V "AAA" x 2 Alkaline Battery
Approx. 250 Times (Once a Day, Room
Temperature 22 oC)
40~104
o
F (5~40
o
C), 30~85% RH
4~140
o
F (-20~60
o
C), 10~95% RH
67mm(W) x 76mm(D) x 32mm(H)
Approx. 128g (Apparatus and Battery)
Wrist Cuff (Fit size 13.5-19.5cm),
Operation Voltage 3V DC
-21-
SPECIFICATIONS
Pulse: 40~200 Beat/min.
*Specitications may be changed Without notice in the event of
lmprovement being made.
TROUBLESHOOTING
ERROR DISPLAY
Nothing is displayed
when you push the
POWER button or
batter yicon flash
E1: Can't normally
increase pressure
E2, E7, E8, E9
Measurement failure
E3. Inflate pressure
too high
E4: Have shaking while
measurement
E5: Automatically pressure
release too fast
E6: Automatically pressure
release too slow
" " Battery icon on
The systolic pressure
value or diastolic
pressure value too high
The systolic pressure
value or diastolic
pressure value too low
POSSIBLE CAUSE
No battery installation
Battery worn out
The polarities of batteries
placed wrongly
Check your cuff if any air
leakage
Wrist cuff not properly
adjust or placement,
hand or body shaking.
Hand or body shaking while
measurement
Cuff too tight
Cuff too loose
Battery low power
1. The hand with the cuff was
held lower than your heart
attached properly
3. You moved your body or
spoke during measurement
HOW TO CORRECT
Insert batteries
Replace new batteries
Insert battery in the correct
polarities
Replace wrist cuff with new one
Renew adjust wrist cuff position
and tightness, and keep hand still
Re-measurement or send back
dealer for re-calibrate pressure
Keeping static and correct gesture
to measure again
Readjust cuff and measure again
Replace battery, and measure again
Keeping correct position and
gesture to measure again
-22-
If you have trouble while using the unit, please check the
following points first.
Instruction Manual
2. The cuff was not
1. The hand with the cuff was
held higher than your heart
2. You moved your body or
spoke during measurement.
Note: 1) Relax for at least 10 minutes and then take another
measurement.
Table of contents
Other Bioland Blood Pressure Monitor manuals