manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BIRD
  6. •
  7. Measuring Instrument
  8. •
  9. BIRD SignalHawk SH-60S-TC User manual

BIRD SignalHawk SH-60S-TC User manual

This manual suits for next models

1

Other BIRD Measuring Instrument manuals

BIRD Thruline 4304A User manual

BIRD

BIRD Thruline 4304A User manual

BIRD ACMI Series User manual

BIRD

BIRD ACMI Series User manual

BIRD SignalHawk SH-36S-RM User manual

BIRD

BIRD SignalHawk SH-36S-RM User manual

BIRD THRULINE 4027F series User manual

BIRD

BIRD THRULINE 4027F series User manual

BIRD Wattcher 3127A User manual

BIRD

BIRD Wattcher 3127A User manual

BIRD O2 User manual

BIRD

BIRD O2 User manual

BIRD Thruline 43 User manual

BIRD

BIRD Thruline 43 User manual

BIRD SignalHawk SH-36S-PC Configuration guide

BIRD

BIRD SignalHawk SH-36S-PC Configuration guide

BIRD 4314B User manual

BIRD

BIRD 4314B User manual

BIRD 5000 User manual

BIRD

BIRD 5000 User manual

BIRD Digital Power Meter Display User manual

BIRD

BIRD Digital Power Meter Display User manual

BIRD TERMLINE 8141 User manual

BIRD

BIRD TERMLINE 8141 User manual

BIRD 5000-XT User manual

BIRD

BIRD 5000-XT User manual

BIRD Termaline 8890SC Series User manual

BIRD

BIRD Termaline 8890SC Series User manual

BIRD 4042 User manual

BIRD

BIRD 4042 User manual

BIRD Termaline 8860SC Series User manual

BIRD

BIRD Termaline 8860SC Series User manual

BIRD THRULINE 4020 series User manual

BIRD

BIRD THRULINE 4020 series User manual

BIRD SiteHawk SK-6000-TC User manual

BIRD

BIRD SiteHawk SK-6000-TC User manual

BIRD 7001A900-2 User manual

BIRD

BIRD 7001A900-2 User manual

BIRD Thruline 43 User manual

BIRD

BIRD Thruline 43 User manual

BIRD THRULINE 4421 User manual

BIRD

BIRD THRULINE 4421 User manual

BIRD 7027 Series User manual

BIRD

BIRD 7027 Series User manual

BIRD ACM Series User manual

BIRD

BIRD ACM Series User manual

BIRD Thruline 4410 series User manual

BIRD

BIRD Thruline 4410 series User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Bird®SignalHawkTM
QUICK START GUIDE
SH-60S-AOA
Birds’ latest oering in the SignalHawk™ family of handheld RF spectrum analyzers.
RF SPECTRUM AT YOUR FINGERTIPS!
BIRD RF Spectrum Analyzers
Operates between
9 KHz - 6 GHz
Everything of the SH-60S-TC,
including spectrogram (waterfall) display
Interference analysis and triangulation functionality
to locate source of interferers
SH-60S-TC SH-60S-AOA
Operates between 9 KHz - 6 GHz
Predened Measurements:
• FM demodulation
• GNSS Signal Quality
• Field Strength
• Spectrum Masking
• Channel Power
• Adjacent Channel Power Ratio (ACPR)
• Phase Noise
• N dB Down Bandwidth
• Occupied Bandwidth (OBW)
SH-60S-AOA extends the capability of the SH-60S-TC by adding the ability to triangulate the location
of an interferer on a map for signals between 9 kHz & 6 GHz.
SH-60S-AOA, RF Spectrum AnalyzerSH-60S-AOA Triangulation
For more info:
t: 440.248.1200
e: [email protected]om
www.birdrf.com
quick-start-guide-signalhawk-AoA-08302022
Triangulation is one technique you may use to determine the location of an of an RF
emitter. The principle is to take three or more measurements from dierent locations,
with each measurement location being 80 to 100 degrees in azimuth away from the
location of the previous measurement. See below for an example of the triangulation
technique.
Due to reections of the emitter’s RF signal (multi-path) and the gain and directivity of
the antenna used with the SignalHawk, the exact location of the emitter may not be
pinpointed with the rst three measurements. However, the measurements will form a
triangle in the area of the emitter. Making additional measurements in the vicinity of the
triangle formed by the initial measurements, will help rene the location.
kTap the System Settings icon.
lTap the GPS
button to turn
GPS on.
mTap Measure
nSelect AoA Locate
oPress OK
AoA Locate (Angle of Arrival)
jTurn on SignalHawk’s WiFi and
connect to a WiFi network.
Start of measurement Slowly rotate 360°
Tap SAVE
pTap MAP to download
an oine map.
qTap to START measurement.
rConnect a handheld directional antenna, tuned to the
frequency of the interfering signal to the SignalHawk.
Red line indicates
direction of
strongest signal.
Repeat until 3 or more
measurements have
been completed & form
a triangle shape near the
assumed position of the
emitter.
Spectrum Mask
Waterfall/spectrogram Display
jTap on Measure
kScroll to Spectrum Mask
lPress OK
Tap here to collapse
or expand screen.
Tap here to create
your own mask. Press
Save Mask when done.
Clear All to erase mask
settings.
Tap Load
Mask to use
a previously
saved mask.
jTap on DISPLAY
kSelect Waterfall or SPEC&WF, press OK
lSelecting Spectrum returns to spectrum
analyzer display
SPEC&WF Waterfall
First
Measurement
Second Measurement
Second
Measurement
SignalHawk
Location
First
Measurement
Third
Measurement
Third Measurement
Second
Measurement
Emitter
Location
First
Measurement
First Measurement
Measured Signal
Strength + Azimuth