Bism SX Series User manual

SX (NELEUS)
SK (re//brass)
SB (Beans)
SS (SUMERGE)
Safety Second Junction
OPERATING MANUAL
Introduction CONTENTS
Introduction ・・・・・・・・・・・・・・・・・1
Important Information
・・・・・・・・・・・ 2
Special Features ・・・・・・・・・・・・・・・2
Precautions
・・・・・・・・・・・・・ ・・・ 3
Names of Parts & Specifications ・・・・・・4~5
Installation of Various Hoses ・・・・・・・・・6
Check before Use & Setting ・・・・・・・6~7
Basic Usage ・・・・・・・・・・・・・・・・8
Care after Use & Storage ・・・・・・・・・・・9
Periodic Inspection & Service after the Sales・10
Troubleshooting ・・・・・・・・・・・・・ 1 1
Key to Symbols Used in this Manual
Danger
Warning
Caution
【Note】 Useful Information to know.
Bism CORPORATION
5F, NF Bldg., Higashinihonbashi, Chuo—ku, Tokyo Japan 103-0004
Phone: +81-3-5640-8126 Fax: +81-3-5640-8131
E-mail: info@bism.co.jp URL: http://www.bism.co.jp
Thank you for purchase of our product.
This manual is the guidebook to provide instructions on
how to use your single hose type safety second
regulator (hereinafter just called safety second) of
open circuit scuba for recreational diving, and B.C.
hose integrated safety second regulator (hereinafter
called junction) of open circuit scuba for recreational
diving.
We believe this manual is useful in mastering
technology of a regulator for people who have learned
the right usage of a regulator and obtained a C-card
through proper training at a diving instruction
organization as well as people who use it at C-card
training. Please carefully read and digest the contents
of this manual before use. We also suggest that you
take this manual with you to refer to before diving.
Keep this manual in a safe place. If you lose it,
contact your original dealer or authorized distributor
of our company. A replacement manual will be reissued
later.
The main contents consist of the check before use,
usage, care after use, storage, and a periodic
inspection.
This product is diving gear to use in combination with
regulator for recreational diving. Therefore, the
knowledge of the right handling of regulator is also
necessary. Please use the operating manual of the
combination equipment which you use as well as this
manual.
In addition, depending on the model of regulator, it is
considered not being suitable for the use by the
combination with this product. We recommend you use by
the combination with the equipment made by Bism.
We are constantly researching and improving our safety
second, and so the product you purchased may differ in
certain details from the one described in this manual.
If you have any queries regarding your safety second or
the information contained in this manual, please feel
free to contact our company at the address lower right.
Danger indicate a great risk of death or
serious injury from improper use.
Warning indicate a risk of death or serious
injury from improper use..
Caution indicate a risk of minor injury or
damage to property from improper use.

Before Use
It is vital to safety that you use and maintain your regulator correctly and have it inspected periodically. Carefully
read and understand the advice on safety given in the manuals of this product and also the combination equipment which
you use before diving.
Warning
● Do not use this product for any purpose other
than recreational diving
■ Use only for recreational diving.
Warning
● Use this product after having obtained a C-card
and completing a proper training program at a
recognized diving school, and be familiar with
the product, or under the instruction of the
diving school. Otherwise it may cause an accident
resulting in injury or death.
■ Obtain C-card before use.
Warning
● When you use this product, please follow all the
instructions about the safety directed in this
operating manual.
■ Please follow instructions about safety.
Warning
● Do not use this product if it is not functioning
normally.
● If the product starts to function abnormally,
contact your original dealer or authorized
distributor of our company. Using a faulty
regulator may cause an accident resulting in
injury or death.
■ Do not use if functioning abnormally.
MPORTANT INFORMATION
Purpose of Use
This product is diving gear for recreational diving use.
The connection with the regulator allows the use and is a spare breathing apparatus for the second stage of regulator
supplying of air in the tank at the time of recreational diving.
The Features of this Product
SPECIAL FEATURES
Since the second stage and a low-pressure hose are connected by the double swivel mechanism, the 360-degree rotation to back and forth and
around is possible for the second stage. As it follows a motion of a diver's face naturally, you can use it comfortably.
The lightweight exclusive plastic hose is adopted as a low-pressure hose. Since it is no odor nature (Food Sanitation Act conformity hose), the
air to supply is also clean. In addition, its excellent flexibility also reduces the stress of your month.
2
■Adoption of Double Swivel
■ Adoption of an exclusive plastic hose
End configuration of couplings for hose is changed into the full conformity form of ANSI.Z86.7.2 of the U.S. diving industry standard from the
JIS threads.
■ Global standard correspondence of couplings for hose.
Junction
B.C. hose integrated spare air supply source.
■ Adoption of Junction Style

Warning
● Please do not fold or pull a hose. It
not only breaks, but it may cause an
accident resulting in injury or death.
□Do not fold or pull a hose.
□Avoid contact with chemicals.
If mercury and chemicals (thinner, gasoline
and various solvents or those cleaner,
adhesives, paint, medicine and cosmetics
which are containing them) adhere,
discoloration and breakage may be occurred
on the main body and hoses.
□Please use designated grease.
Please apply the designated grease to the
designated portion only. Breakage may be
caused, if greases other than designated
are used or you apply to the portion out of
the designation. (Please refer to “Installation of Various
Hoses”in the page 9)
Warning
● This product is designed to attach to
the tank which can fill up 250bar or
less with the air in the atmosphere.
Therefore, the tank with pure oxygen or
high fraction of oxygen cannot be used.
□Check the tank to use.
□Follow the safety rules.
Only use under the direction of a recognized diving school or
after obtaining a C-card having completing a proper training
program at a recognized diving school and thoroughly
familiarizing yourself with the correct use of a regulator.
Have your buddy double check everything.
Avoid diving deeper than 30m/98ft. (This is the maximum safe
depth for normal recreational diving.)
□Please use the Bism made hose guard.
Please do not attach hose guards and hose protectors other than
our products to a low-pressure hose. It may cause hose breakage.
□Avoid shocks.
Though the product can withstand the shock in
the usual use, drops and hard knocks may
damage it.
Warning
● It is a regulator for recreational diving to use in
the normal water area (the ocean, a lake, fresh water
and seawater swimming pool). You cannot use it in
special environment containing a medicine, a solvent,
oil, etc.
□Do not use it in special environment.
PRECAUTIONS
□Do not modify the product.
Since it may become a safety problem,
please do not modify the product.
Responsibility cannot be taken about the
trouble after modification.
Warning
● A regulator does not operate
normally when the water pressure
sensor hole of the first and second
stage of a regulator is blocked up.
Please do not block up the water
pressure sensor hole.
□Do not block up the water pressure sensor hole.
3
● Please do not use the tank with the fraction of
oxygen of greater than 40% for the regulator made out
of titanium. Ignition and combustion is generated,
and it may cause an accident resulting in injury or
death.
Gasoline
Grease Oxygen

4
NAMES OF PARTS & SPECIFICATIONS
Names of Parts Specifications
Weight (Including Hose)… 360 g
Width of Exhaust Tee………… 90 mm
Operation Method……………… Combined Use of Diaphragm and Downstream
Temperature Range………… +5~+ 50℃
Material Body Case: POM Plastic
Face Cover: Pure Titanium
Mouth Piece: Silicone Rubber
Valve: Titanium, POM Plastic
SX2310K
Second Stage
Names of Parts Specifications
Weight (Including Hose)… 382 g
Width of Exhaust Tee………… 90 mm
Operation Method……………… Combined Use of Diaphragm and Downstream
Temperature Range………… +5~+ 50℃
Material Body Case: POM Plastic
Face Cover: ABS Plastic
Mouth Piece: Silicone Rubber
Valve: Copper Alloy, POM Plastic
SK2730
Second Stage
Names of Parts Specifications
Weight (Including Hose)… 380 g
Width of Exhaust Tee………… 90 mm
Operation Method……………… Combined Use of Diaphragm and Downstream
Temperature Range………… +5~+ 50℃
Material Body Case: POM Plastic
Face Cover: ABS Plastic
Mouth Piece: Silicone Rubber
Valve: Copper Alloy, POM Plastic
SB2600
Second Stage
Exhaust Tee
Front Face Cover
Low Pressure Hose
Mouth Piece
Water Pressure
Sensor Hole
Double Swivel
Purge Button
Exhaust Tee
Front Face Cover
Low Pressure Hose
Mouth Piece
Water Pressure
Sensor Hole
Double Swivel
Purge Button
Exhaust Tee
Front Face Cover
Low Pressure Hose
Mouth Piece
Water Pressure
Sensor Hole
Double Swivel
Purge Button

NAMES OF PARTS & SPECIFICATIONS
5
Names of Parts Specifications
Weight (Including Hose)… 382 g
Width of Exhaust Tee………… 90 mm
Operation Method……………… Combined Use of Diaphragm and Downstream
Temperature Range………… +5~+ 50℃
Material Body Case: POM Plastic
Face Cover: ABS Plastic
Mouth Piece: Silicone Rubber
Valve: Copper Alloy, POM Plastic
SS2600
Second Stage
Hose Specifications
Common to SX, SK, SB and SS
Specifications
Weight (Including Hose)… 425 g
Width of Exhaust Tee………… 90 mm
Operation Method……………… Combined Use of Diaphragm and Downstream
Temperature Range………… +5~+ 50℃
Material Body Case: POM Plastic
Face Cover: ABS Plastic
Mouth Piece: Silicone Rubber
Valve: Copper Alloy, POM Plastic
SB2601
Second Stage
Nominal Size of Coupling Threads………… 3/8-24UNF
Hose Working Pressure……… 15 bar
Minimum Bending Radius (Inside of Hose)… 15 m m
Hose Guard
……………………… Regular Equipment
Material: Elastomer Plastic
Hose Length……………………… 800 mm
Outer Diameter……………………… 13 m m
Material of Inner Tube and Outer Cover……… Vinyl Chloride
Material of Couplings…………………… Copper Alloy
Exhaust Tee
Front Face Cover
Low Pressure Hose
Mouth Piece
Water Pressure
Sensor Hole
Double Swivel
Purge Button
Hose Specifications
Nominal Size of Coupling Threads………… 3/8-24UNF
Hose Working Pressure……… 15 bar
Minimum Bending Radius (Inside of Hose)… 15 m m
Hose Guard
……………………… Regular Equipment
Material: Elastomer Plastic
Hose Length……………………… 170 - 550 mm
Outer Diameter…………………… 13 m m
Material of Inner Tube and Outer Cove………… Vinyl Chloride
Material of Couplings…………………… Copper Alloy
Exhaust Tee
Front Face Cover
Low Pressure Hose
Mouth Piece
Water Pressure
Sensor Hole
Double Swivel
Purge Button

6
Installation of Low Pressure Hoses
* Low Pressure Hose: The hose for safety second.
Warning
● Please install the low pressure hose to an L.P. port,
and only the thread size of 3/8-24UNF of low pressure
hose couplings should be connected. Otherwise, not only
it causes the damage of equipment, but also a hose comes
off and it may cause an accident resulting in injury or
death.
1
2
Please remove the plug from the L.P. port of the first stage of
a regulator.
Please screw in the coupling of a low pressure hose to L.P. port and turn it
clockwise with a spanner to tighten it. Tightening torque is 9.8 N・m (100 kgf・
m).
INSTALLATION OF VARIOUS HOSES
Caution
● Please ask the authorized distributor of our company for installation of high and low pressure hoses and
plugs.
● When you tighten hose couplings with a spanner, please keep the tightening torque (1/36 turns from a
tightening start) of 9.8N・m (100kgf・cm). Otherwise it may cause to damage the threads portion. In the
case of the value of tightening torque listed in the operating manual of a tightened side (gauge, safety
second, etc.) is smaller than 9.8N, m, please follow the value.
Warning
● Please attach a hose in the state that the first stage of a regulator is not connected
to a tank. If the first stage is pressurized during work, a plug in the port flies and
it is dangerous.
● Please confirm that O-rings are set at the threads portion of each hose. When there are
no O-rings, it causes the air leakage.
Check of the hoses.
Warning
● If there is an abnormality in your regulator by following various checks, you must not use it.
● When there is an abnormality, contact your original dealer or authorized distributor of our company. Use
of the regulator which is not normal may cause an accident resulting in injury or death.
Before setting your regulator to a tank valve, please check whether
the hose is damaged or has not broken.
All the hoses, such as a hose of the safety second connected to the
first stage and a high pressure hose, are to be checked.
CHECK BEFORE USE & SETTING
1Check of the second stage.
Check if there is any crack in each part of the second stage by
visual.
Warning
● Please check whether the face cover is
tightened enough.
If not, please retighten it.
2

7
Check that the O-ring is attached to the tank valve.
(1)
Turn a yoke screw to the right, and tighten it until the end
connection stops shaking.
(3)
Making the direction of the second stage of a regulator so as it
comes out of a right shoulder, and put a yoke so that the end
connection of the first stage of a regulator may suit the groove
of the O-ring of the tank valve.
(2)
Setting the regulator to a tank.
Caution
● Please do not tighten a yoke screw too much
strongly. It may be unable to take off after use.
Warning
● Please open a tank valve after
checking that the regulator is set to
a tank in the right direction, and
that the yoke screw is tightened
firmly.
● Please open the tank valve slowly.
3
CHECK BEFORE USE & SETTING (Continued)
Open the tank valve slowly and once it gets to full open, return
by half-rotation.
(5)
【Note】
○ A tank valve also has a kind. The question about a tank valve
should read the operating manual of the tank valve.
Before opening the tank valve, please hold a mouthpiece in your
mouth and inhale air to check if the air does not leak and does
not come in to your mouth.
(4)
Connect a quick-coupler to inflator.
(In the case of junction)
4
Warning
● When you perform the connecting work of a quick-
coupler, close the tank valve, depress the purge
button of a regulator to release the pressurized
air in a hose.
Connect a quick-coupler to a nose
of B.C. inflator while sliding a collar
of the quick-coupler.
(1)
While pulling the quick-coupler by gripping the end of it, check
whether it comes off. When it comes off, please start it again
from the beginning.
(3)
Grip the end of the quick-coupler
and push it until it sounds
"click".
(2)
Collar
Nose
Check of the air leakage.
(1)Before opening the tank valve, please hold a mouthpiece in your
mouth and inhale air to check if the air does not leak and does not
come in to your mouth.
(2) Open the tank valve slowly and once it gets to full open, return
by half-rotation.
(3)Check if there is any air leakage on the first and second stage of
regulator, connecting portion of hose and hose itself.
(4)When air leaks from connecting portion to inflator (around the
quick-coupler), close the valve, release the residual pressure in a
hose by depressing purge button of a regulator second stage, and then
install the quick-coupler again recheck the air leakage.
(If air still leaks, stop to use it and consult with your original
dealer or authorized distributor of our company.)
5
Check of the air intake and exhaust.
Please hold a mouthpiece in your mouth, breathe with a mouth 4 ~ 5
times, and check that air flows normally.
Bite the projection portion of a mouthpiece lightly with your teeth,
and hold it in your mouth so that the whole may be covered with lips..
Cover with your lips.
How to Hold a Mouthpiece in Your Mouth.
Caution
● Please do not bite the projection portion of a
mouthpiece strongly. You may cut it off, if you
bite strongly.
Warning
● After setting, when air does not come out from the
second stage of the regulator normally, please do
not use it.
● When the inhaled air has a smell, please stop to
use the tank and change for other tanks. When the
air still has a smell even if you change a tank,
please stop to use the regulator.
6
Bite with your teeth.

8
Warning
● Please be sure to breathe, after draining by performing regulator clearing before inhaling air.
It may cause drowning by drinking water accidentally.
● If it carries out in the state that regulator clearing is not mastered, it may cause drowning by drinking water.
Please perform practice of regulator clear under instruction of a diving school.
Warning
● Please do not bite the projection
portion of a mouthpiece strongly.
Otherwise, as you may cut it off,
and there is a possibility of
becoming easy to separate from
a mouth which leads to be
drowned, thus it may cause an
accident resulting in injury or
death.
● Please hold the second stage in
your mouth so that a hose
installed portion comes to a lower
position.
Breathing
After holding a mouthpiece in your mouth and performing regulator
clear, breathe with your mouth deeply and slowly.
How to Hold a Mouthpiece
Hold it in your mouth so that a mouthpiece comes to an upper position
and a hose comes to a lower position.
Regulator Clearing
Before inhaling air, perform discharge operation of water which entered in the second stage of a regulator. (Regulator Clear)
【Note】○ Water can be effectively discharged by taking an upward slanting posture.
If a Free Flow is Carried Out・・・
▼Please plug up the hole of a mouthpiece with a palm or a finger.
Caution
● Although a free flow may be
carried out from the second stage
of a regulator immediately after
an entry, if you cannot stop it by
the method explained below, please
stop use.
■ Regulator Clearing with the Purge Button.
In the state of holding a mouthpiece in your mouth, depress the purge
button while exhaling.
Since water may remain, inhale air slowly so that you may not drink
water, and if the water still remains carry out the same once again.
■ Regulator Clear by Exhaling.
In the state of holding a mouthpiece in your mouth, exhale air
strongly to blow off the water in the second stage.
Since water may remain, inhale air slowly so that you may not drink
water, and if the water still remains carry out the same once again.
【Note】
○ While breathing, if a face cover side of a regulator is turned to
the surface, breathing resistance will increase.
Exhale air strongly. Exhale air strongly.
▼Turn mouthpiece downward underwater.
BASIC USAGE
【Note】
○ By the direction of second stage, such as immediately after an
entry, air may blow off from a mouthpiece portion. It is not failure
when it stops by the above mentioned method.

9
Removal from a Tank.
Close a tank valve. 1
Push a purge button to release the air inside a regulator
completely. 2
Caution
● Please be sure to release the compressed air in a
regulator, before working to remove the first
stage of a regulator from a tank valve. If it is
not released, it may lead an explosion and cause
an accident resulting in injury or death.
Disconnect Quick-Coupler from B.C. Inflator.
(In the case of junction)
According to the operating manual of a regulator and a tank for
SCUBA diving, close the tank valve.
Caution
● Before disconnecting a quick-coupler of B.C. hose
from inflator, be sure to close the tank valve,
depress the purge button of a regulator to
release the pressurized air in a hose.
Loosen yoke screw and remove a regulator.
Depress the purge button of regulator second stage to release
residual air in a hose.
After removing the water of the dust cap enough with an air blow
or a towel, turn a yoke screw and fix to the connecting portion
of the first stage of a regulator firmly.
CARE AFTER USE & STORAGE
Wash
Soak the whole equipment to
fresh water for about 15
minutes in the state of
being set with the
regulator. Then, rinse the
whole in water to wash the
salt away.
Caution
● Equipment may be damaged if soaked in hot water
of 50℃ or more.
● Please do not push purge button of the second
stage of a regulator by any means during washing.
Water comes in and may cause the trouble.
● Please be sure to put the dust cap of the first
stage of a regulator firmly. Otherwise water
comes in the gauge and hose, and it causes
failure.
Pour water on the groove
portions of mouthpiece and
face of second stage, and
rinse them.
【Note】
○ When you push the purge button of the second stage of a regulator
by accident during washing, connect the first stage to a tank again
and push the purge button to blow off internal water. Then, contact
your original dealer or authorized distributor of our company.
3Pull the collar of a quick-
coupler and disconnect from
the nose as it is.
1
2
3
4

10
■ Wash and dry a regulator fully.
■ Avoid direct rays, and store a regulator after making it fully dry
in the shade with the dry, cool and sufficient ventilation.
Drying-Out and Storage
Caution
● Please keep the hose in a natural form. Forced
bending causes kinking of a hose and shorten a
hose life remarkably.
● If you leave a regulator in
the state of high
temperature, such as in a car
or on a beach, it may
interfere with a function.
● When a translucent mouthpiece
and white parts (hose etc.)
are left under sunlight or a
fluorescent light for a long
time, it may yellow.
Moreover, if they touch
rubber commodities, such as a fin, for a long
time, a color of the rubber may stain.
【Note】
● Some parts carry out natural deterioration. Exchange of such parts
is also performed by periodic check.
Caution
● Please ask your original dealer or authorized
distributor of our company for a periodic
inspection per once in a year or once in every
100 dives.
● Regardless whether or not you use it, regulator
may not function normally when you ignore a
periodic inspection.
■Please ask your original dealer or authorized distributor of our
company for a periodic inspection per once in a year. (Pay Service)
Service after the Sales
□ When your regulator is out of condition, check it first.
Please refer to the clause of "Troubleshooting" and check whether it is failure.
□ When it is still out of order;
Please contact your original dealer or authorized distributor of our company.
□ Reserving period of parts.
Our company reserves the performance parts (the parts required to maintain the function of the product) for
repairing a regulator for at least 8 years after the production is discontinued. Since repair may be
possible depending on a problem even after this reserving period passes, please consult with your original
dealer or authorized distributor of our company.
Periodic Inspection
PERIODIC INSPECTION & SERVICE AFTER THE SALES

11
Please check it once again before sending it to repair. When still not operating normally, please consult with your
original dealer or authorized distributor of our company for repair.
TROUBLESHOOTING
Trouble Major Cause Measure Page
Air does not
ow.
○ A failure to open the cock of a
tank valve.
○ A tank is empty.
○ Water pressure sensor hole of
either rst stage or second stage
is blocked
○ Open the tank valve.
○ Change to a tank with full of air.
○ Check whether the water pressure
sensor hole is blocked.
7
7
3
Inhalation
resistance is
high.
○ There is little air in a tank.
○ Tank valve is not fully opened.
○ Operation failure of the second
stage.
○ Water pressure sensor hole of
either rst stage or second stage
is blocked.
○ Change to a tank with full of air.
○ Make a tank valve full open.
○ Consult with your original dealer
or authorized distributor of our
company
○ Check whether the water pressure
sensor hole is blocked.
7
7
-
3
Exhalation
resistance is
high.
○ Fixing of body case and exhaust
valve.
○ Dip in water and melt the crystal
of salt.
9
Free ow ○ Air is blow off by Venturi
effect.
○ Block the hole of mouthpiece, or
face it downward.
8
Water comes in to
the second stage.
○ Regulator clear is not enough.
○ A foreign substance is caught
in an exhaust valve.
○ Slack and crack of a
mouthpiece.
○ Crack of a second body case.
○ Perform the regulator clear again.
○ Check of the exhaust valve.
○ Check of a mouthpiece.
○ Consult with your original dealer
or authorized distributor of our
company
8
-
-
-
Air leakage from
the rst stage.
○ Thread portion of a hose loosen
or comes off.
○ Abrasion of O-ring of an air
leak portion, a crack and a
foreign substance.
○ Retighten the thread portion of
all hose.
○ Consult with your original dealer
or authorized distributor of our
company
6
-

12 20150605MR
Bism CORPORATION
5F, NF Bldg., Higashinihonbashi, Chuo—ku, Tokyo Japan 103-0004
Phone: +81-3-5640-8126 Fax: +81-3-5640-8131
E-mail: [email protected] URL: http://www.bism.co.jp
Memo
This manual suits for next models
8
Table of contents