Bitstream HYPERION-402 Instruction manual

Quick start manual for H-402 - www.bitstream.pl/ en/
HYPERION-402
Managed Industrial Ethernet Switch
1 DE ICE PANEL
Fig 1. Back panel Hyperion-402 depending on the device version
Fig 2. Front panel Hyperion-402 depending on the device version
Description:
1 – Ethernet ports connectors (SFP or RJ45) depending on version
2 – Management port connector (ET with RJ-45 10/100M)
3 – Power connectors
4 – GND clamp with screw
5 – Signalling LEDs
6 – Ethernet port connectors 1G/2,5G/10G (SFP/SFP+) – module Central Unit
7 – DEF – button for restoring the default configuration
8 – Console RS-232, 115 200bps
9 – Mechanical components for mounting in a 19" rack (Included) - front or rear mount version
S ORT USER MANUAL YPERION-402 1/6REV. 1.08 2021.03.31
5
1
2
6
83
5
7
4
9

Quick start manual for H-402 - www.bitstream.pl/ en/
1.3 Description of device connectors
RJ-45 connectors.
Fig 5. The look and numbering of leads in J45 connector
The table shows the lay-out of particular signals for RJ-45 connectors.
Status signaling of Ethernet interfaces
Each Ethernet port is equipped with two signaling diodes.
The left LED indicates link:
• LED 100M – orange – link 100Mbps (if activity – blinking)
• LED 1000M – green – link 1000Mbps (if activity – blinking)
The right LED indicates the power of PoE:
• LED orange – power indicator flashing for special mode "manual" (Permanently powered port with the PoE
detection turned off)
• LED green – delivered power in PoE+ or PoE++
Distribution of signals for the serial port connectors shown in the following table:
RJ-45
connector PORT RS232 DSUB-9
(female)
5 GND 5
7 TX – RX 2
8 RX – TX 3
S ORT USER MANUAL YPERION-402 3/6REV. 1.08 2021.03.31
RJ-45 Ethernet 10/100Mbit/s CONNECTOR
1 (white and orange) RXAn Receiver of channel
2 (orange) RXBn
3 (white and green) TXAn Transmitter of channel
6 (green) TXBn
RJ-45 Ethernet 1000Mbit/s CONNNECTOR
1 (white and orange) BI_DA+ Bi-directional +A contact
2 (orange) BI_DA- Bi-directional -A contact
3 (white and green) BI_DB+ Bi-directional +B contact
4 (blue) BI_DC+ Bi-directional +C contact
5 (white and blue) BI_DC- Bi-directional -C contact
6 (green) BI_DB- Bi-directional -B contact
7 (white and brown) BI_DD+ Bi-directional +D contact
8 (brown) BI_DD- Bi-directional -D contact

Quick start manual for H-402 - www.bitstream.pl/ en/
1.4 Description of SFP optical ports
The optical ports are equipped with SFP slots and CU module with four dedicated SFP/SFP +
slots. The range and type of connector depends on the type of SFP insert. SFP slots support 100 and
1000 Mbit/s and SFP/SFP + slots support 1G/2.5G/10Gb.
Status signaling of SFP optical ports
•External LED – signals transmission link for 1Gbps (if activity – blinking)
•Internal LED – signals transmission link for 100Mbps (if activity – blinking)
Range and type of connector depends on the type of SFP insert.
2POWER SUPPLY
Supply voltage range:
•version 7 – 36-60VDC power supply, for PoE in the range of 45-57VDC
•version C – 80-360VDC or 75-270VAC power supply,
•version 77p – 36-60VDC redundant power supply, for PoE in the range 45-57VDC
•version CCp – 80-360VDC or 75-270VAC redundant power supply
•75-270VAC power supply does not support PoE function
•Optional two supply inputs – redundant
•Screw block connectors for DC or AC power supply
•Total power consumption (without PoE ports) - <50W
•Power supply also have power LED indicator (for each power supply)
•Screw for GND connection
•The power supplies in the device are protected against inverted power polarity. In case of
reversing the polarity at the moment of connecting the power supply, the device will work.
3POE POWER SUPPLY (ADDITIONAL OPTION)
– Compliant with the IEEE802.3af standard, IEEE802.3at
– For 45-57V DC power, the power available for each port up to 30 or 90W. (depending on
selected version)
– For 55VDC power, the maximum total PoE power is 500W
4FIRST START-UP
After connecting the power supply with appropriate parameters to the inputs, the PWR LED should
first light up, flashing alternately in two colours: orange and green, and then switch only to green. If
only one of the power supply inputs is used, only one PWR diode corresponding to this input will
light up.
The red "ERR" LED's indicating the status of the modules and start blinking, which indicates that
the device is starting up. When the "ERR" LED's do not light up, the switch is ready for operation.
The device can be managed using the recommended Ethernet NMI or RJ45 interface via the RS-
232 console.
5DEFAULT PARAMETERS
IP parameters:
Address: 192.168.0.10 Mask: 255.255.255.0
User: admin Password: no password (empty)
S ORT USER MANUAL YPERION-402 4/6REV. 1.08 2021.03.31

Quick start manual for H-402 - www.bitstream.pl/ en/
6MANAGEMENT
Management of the device applies TTP and SNMP protocols, and can be performed via NMI
Ethernet port or any Ethernet ports. Additionally, access to the device parameters is possible via
SS or RS232 console.
Note!!!: In the indicated models of switches, the firmware update from a version older than:
HYPERION-105 – v120
HYPERION-300 – v120
HYPERION-303 – v120
HYPERION-200 – v308
HYPERION-400 – v308
HYPERION-500 – v308
This will remove passwords for users existing in the configuration (including the "admin"
user).
After the upgrade, the password for each user will be blank the first time they attempt to log
in to management via WWW or CLI.
In case of the firmware is downgraded to a version lower than the one indicated above, the
users will be completely removed and a default user "admin" will be created with no
password – empty.
7 Emergency restoring access to the device
If the password is lost, there is a mechanism for generating a temporary password to access the
device via www or telnet or CLI. If you enter the password incorrectly five times via telnet or CLI or
by entering the %bitstream% command in the password field, a temporary code will be generated.
The code must be forwarded to the BitStream Support department available from 8:00 to 16:00 at
817438643 or sent by e-mail to support@bitstream.pl to receive a temporary 6-hour password to
access the device.
If you cannot log in to the device (due to incorrectly entered configuration e.g.: vlan, etc.), you can
restore the default configuration using the "DEF" button. olding down the "DEF" button for 5
seconds will delete the configuration without losing the IP address, and holding down the button for
more than 10 seconds will restore the configuration to factory settings.
8 CONFORMITY TO STANDARDS AND RECOMMNEDATIONS
BITSTREAM devices were designed pursuant to obligatory standards and recommendations in
respect of the range of data transmission, electromagnetic compatibility and service safety.
8.1 Electromagnetic compatibility
The device was designed pursuant to the standard EN 55022, EN-55024. BITSTREAM devices
are designated to functioning in closed premises.
Notice: This device is a class A device. In the residential environment may cause radio frequency
interference. In such cases, you can require the user to take appropriate measures.
8.2 Safety
In respect to safety of service, BITSTREAM devices were designed and tested for
operation safety along with the EN 60950 standard.
Configuration and installation of the device should be executed by authorised persons familiar with
the service manual. The producer shall not be responsible for any occurrence that could result
from usage and installation that might not conform to this manual.
S ORT USER MANUAL YPERION-402 5/6REV. 1.08 2021.03.31

Quick start manual for H-402 - www.bitstream.pl/ en/
8.3 Data transmission
The following norms and recommendations determine the functions of data transmission and
communication interface parameters of the device.
• IEEE 802.3 10Base-T Ethernet
• IEEE 802.3u 100Base-TX Fast Ethernet, 100Base-FX Fast Ethernet Fiber
• IEEE 802.3ab 1000Base-T
• IEEE 802.3z Gigabit Fiber
• IEEE 802.3ae 10GBASE-SR/LR/ER/ZR (SFP+) – 10 Gigabit Ethernet
• IEEE 802.3x Flow Control and Back-pressure
• IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
• IEEE 802.1p Class of Service (CoS)
• IEEE 802.1Q VLAN
• IEEE 802.1ad QinQ
• IEEE 802.1d – Spanning Tree Protocol
• IEEE 802.1w – Rapid Spanning Tree Protocol (RSTP)
• IEEE 802.1s – Multiple Spanning Tree Protocol (MSTP)
• IEEE 802.3ad Link Aggregation Protocol (LACP)
• IEEE 802.1x Port Based Network Access Protocol
• IEEE 802.3az EEE
• IEEE 802.3af/at typ 1/2 i PoE++ 90W/port
• IEEE 802.30ah Link OAM
ITU K.44 – standard built-in overvoltage protection on RJ45 ports 4kV 10/700us: Resistibility
tests for telecommunication equipment exposed to overvoltages and overcurrents – Basic
Recommendation
9 PACKING COMPLETION OF THE PRODUCT
S ORT USER MANUAL YPERION-402 6/6REV. 1.08 2021.03.31
1 1 pcs.
2 Serial cable for configuration 1 pcs.
3 Short user manual 1 pcs.
4 Declaration of confirmity 1 pcs.
5 Warranty Card 1 pcs.
6 Rack-mounted brackets 2 pcs.
yperion-402
Table of contents
Other Bitstream Switch manuals
Popular Switch manuals by other brands

Belkin
Belkin 4-Port USB 2.0 Hub user manual

HPE
HPE JH323A installation guide

Belkin
Belkin OMNIVIEW P72021 user manual

SMC Networks
SMC Networks SMC-EZ108DT Technical specifications

National Instruments
National Instruments NI-DAQ 7 Getting started guide

KELCO
KELCO D40 Installation and operating instructions