BKI FH-28CT COUNTERTOP User manual

CS-TM-041.01 Revised 04/17/13
Ventless Hood System
MODEL H-28CT COUNTERTOP
Service Manual

CS-TM-041.01 Revised 04/17/13
BKI LIMITED WARRANTY
2812 Grandview Dr. • Simpsonville, SC 29680 • USA
(864 963-3471 • Toll Free: (800 927-6887 • Fax: (864 963-5316
WHAT IS
COVERED
This warranty covers defects in material and workmanship under normal use, and applies
only to the original purchaser providing that:
T
he equipment has not been accidentally or intentionally damaged, altered or misused;
The equipment is properly installed, adjusted, operated and maintained in accordance
with national and local codes, and in accordance with the installation and operating
instructions provided with this product.
The serial number rating plate affixed to the equipment has not been defaced or
removed.
WHO IS
COVERED
This
warranty
is
extended
to the original
purchaser
and applies only
to
equipment purchased
for use in the U.S.A.
COVERAGE PERIOD
Warranty claims must be received in writing by BKI within one (1) year from
date of installation or within one (1) year and three (3) months from data of
shipment from the factory, whichever comes first.
COB Models: One (1) Year limited parts and labor.
COM Models: Two (2) Year limited parts and labor. COM convection ovens also have
a two (2) year door warranty.
CO1 Models: Two (2) Year limited parts and labor. ive (5) Year limited door
warranty.
BevLes Products: Two (2) Year limited parts and labor.
Warranty period begins the date of dealer invoice to customer or ninety (90) days
after shipment date from BKI, whichever comes first.
WARRANTY COVERAGE
This
warranty
covers on-site labor, parts and
reasonable
travel
time
and travel
e
xpenses
of the
authorized
service
representative
up
to
(100) miles
round
trip and (2)
hours
travel time and
performed
during
regular,
weekday
business
hours.
EXCEPTIONS
Any exceptions must be pre-approved in advance and in writing by BKI. The
extended door warranty on convection ovens years 3 through 5 is a parts only warranty and
does not include labor, travel, mileage or any other charges.
EXCLUSIONS
Negligence
or acts of
God,
Thermostat
calibrations
after (30) days
from
equipment
installation
date,
Air and g
as
adjustments,
Light
bulbs,
Glass doors and
door
adjustments,
uses,
Adjustments
to
burner
flames and
cleaning
of
pilot
burners,
Tightening
of screws
or
fasteners,
ailures
caused
by erratic
voltages
or gas
suppliers,
Unauthorized
repair by
anyone
other
than
a BKI
actory
Authorized
Service Center,
Damage
in
shipment,
Alteration,
misuse or
improper
installation,
Thermostats
and safety valves with
broken
capillary tubes,
reight
–
other
than
normal UPS charges,
Ordinary
wear and
tear,
ailure to follow
installation
and/or
operating
instructions,
Events
beyond
control
of the
company.
INSTALLATION
Leveling, as well as
proper
installation
and check out of all
new
equipment
-
per
appropriate installation
and use materials – is t
he
responsibility of the
dealer
or
installer, not the
manufacturer.
REPLACEMENT PARTS
BKI
genuine
actory OEM parts receive a (90) day
materials
warranty
effective from the
date of
installation
by a BKI
actory
Authorized
Service
Center.

Ventless Hood System Table of Contents
1
Table of Contents
Table of Contents ........................................................................................................................................1
Introduction..................................................................................................................................................2
Safety Precautions ....................................................................................................................................2
Safety Signs and Messages .................................................................................................................2
Specific Precautions .............................................................................................................................2
Safe Work Practices .............................................................................................................................3
Safety Labels ........................................................................................................................................4
Hood Specifications ..................................................................................................................................4
Cooktop Specifications..............................................................................................................................4
Installation....................................................................................................................................................5
Unpacking and Handling ...........................................................................................................................5
Inspection for Shipping Damage...........................................................................................................5
Location and Clearance ........................................................................................................................5
Assembly and Mounting............................................................................................................................5
Hood Mounting......................................................................................................................................5
Particle/Odor ilter................................................................................................................................6
ire Damper ..........................................................................................................................................6
Air Deflector ..........................................................................................................................................7
ire Extinguishing System ....................................................................................................................7
Wiring ......................................................................................................................................................15
Maintenance...............................................................................................................................................18
Scheduled Maintenance..........................................................................................................................18
Cleaning the Grease Baffle.................................................................................................................19
Replacing the Particle/Odor ilter.......................................................................................................19
Replacement Parts ....................................................................................................................................20
Wiring Diagrams ........................................................................................................................................26
Notes...........................................................................................................................................................27

Ventless Hood System Introduction
2
Introduction
Congratulations! You have chosen BKI’s Ventless Hood system, a state-of-the-art unit that filters grease
laden air and returns it to the room.
The BKI name and trademark on this unit assures you of the finest in design and engineering -- that it has
been built with care and dedication -- using the best materials available. Attention to the operating
instructions regarding proper operation, installation and maintenance will result in long lasting
dependability to insure the highest profitable return on your investment.
PLEASE READ THIS ENTIRE MANUAL BE ORE OPERATING THE UNIT. If you
have any questions, please contact your BKI Distributor. If they do not answer
your questions, contact the BKI Technical Service Department, toll free: 1-800-
927-6887. Outside the U.S., call 1-864-963-3471.
Safety Precautions
Always follow recommended safety precautions listed in this manual. Below is the safety alert symbol.
When you see this symbol on your equipment, be alert to the potential for personal injury or property
damage.
Safety Signs and Messages
The following Safety signs and messages are placed in this manual to provide instructions and identify
specific areas where potential hazards exist and special precautions should be taken. Know and
understand the meaning of these instructions, signs, and messages. Damage to the equipment, death or
serious injury to you or other persons may result if these messages are not followed.
This message indicates an imminently hazardous situation, which, if not avoided,
will result in death or serious injury.
This message indicates a potentially hazardous situation, which, if not avoided,
could result in death or serious injury.
This message indicates a potentially hazardous situation, which, if not avoided,
may result in minor or moderate injury. It may also be used to alert against unsafe
practices.
This message is used when special information, instructions or identification are
required relating to procedures, equipment, tools, capacities and other special
data.
Specific Precautions
Carbon monoxide poisoning will result from using this hood with any appliance
that utilizes combustible fuel. Use only electrical appliances with this hood.
Hood failure could result if the hood is operated without the grease baffle and
particle/odor filter installed. This is a special filter designed for this application
only; other filters will not work properly. Use only a BKI particle/odor filter.

Ventless Hood System Introduction
3
Safe Work Practices
Beware of High Voltage
This equipment uses high voltage. Serious injury can occur if you or any
untrained or unauthorized person installs, services, or repairs this equipment.
Always Use an Authorized Service agent to Service Your Equipment
Keep this manual with the Equipment
This manual is an important part of your equipment. Always keep it near for easy
access. If you need to replace this manual, contact:
BKI
Technical Services Department
2812 Grandview Drive
Simpsonville, S.C. 29680
Or call toll free: 1-800-927-6887
Outside the U.S., call 864-963-3471
Protect Children
Keep children away from this equipment. Children may not understand that this
equipment is dangerous for them and others.
NEVER allow children to play near or operate your equipment.
Keep Safety Labels Clean and in Good Condition
Do not remove or cover any safety labels on your equipment. Keep all safety
labels clean and in good condition. Replace any damaged or missing safety
labels. Refer to the Safety Labels section for illustration and location of safety
labels on this unit. If you need a new safety label, obtain the number of the
specific label illustrated on page 4, then contact:
BKI
Technical Services Department
2812 Grandview Drive
Simpsonville, S.C. 29680
Or call toll free: 1-800-927-6887
Outside the U.S., call 864-963-3471
911
Prepare for Emergencies
Be prepared for fires, injuries, or other emergencies.
Keep a first aid kit and a fire extinguisher near the equipment. You must use a
40-pound Type BC fire extinguisher and keep it within 25 feet of your equipment.
Keep emergency numbers for doctors, ambulance services, hospitals, and the
fire departments near your telephone.
Know your responsibility as an Employer
• Make certain your employees know how to operate the equipment.
• Make certain your employees are aware of the safety precautions on the
equipment and in this manual.
• Make certain that you have thoroughly trained your employees about
operating the equipment safely.
• Make certain the equipment is in proper working condition. If you make
unauthorized modifications to the equipment, you will reduce the safety and
function of the equipment.

Ventless Hood System Introduction
4
Safety Labels
Hood Specifications
Power 208/120V or 240/120V (Neutral wire required)
Phase 1 or 3 (see wiring instructions)
Hood Blower Motor 1/2 HP
use or Breaker size 40A
Wire Size Minimum recommended wire size for all leads and neutral is 8 ga.
Note: Above specifications include the load of 4 cooktop appliances (1.5KW) powered by the hood.
Cooktop Specifications
Volts 120V
Phase 1
Maximum Amps 12.5A
Maximum Input 1500W
requency 60 Hz
Maximum combined cooking surface area 450 sq. in. (2903 sq. cm.)
Maximum cooking surface temperature 450° . (232° C.)
USE UL LISTED APPLIANCES ONLY

Ventless Hood System Installation
5
Installation
Unpacking and Handling
Inspection for Shipping Damage
YOU are responsible for filing all freight claims with the delivering truck line. Inspect all cartons and crates
for damage as soon as they arrive. If damage to cartons or pallets is found, or if a shortage is found, note
this on the bill of lading (all copies) prior to signing and receiving.
If damage is found when the equipment is opened, immediately call the delivering truck line and follow up
the call with a written report indicating concealed damage to your shipment. Ask for an immediate
inspection of your concealed damage item. Packaging material MUST be retained to show the inspector
from the shipping line.
Location and Clearance
Place the ilter Hood in a location with clearance as shown below. These distances provide for proper
clearance to combustible surfaces, access for maintenance, and proper air flow from hood exit vent.
MINIMUM CLEARANCE HOOD TO
COMBUSTIBLE 18 in. ( H-28) SIDES, 0 in.
BACK, 0 in. TOP, 0 in. BOTTOM
APPLIANCE CLEARANCE Cooking surface
must be at least 3.5 inches behind the front edge
of the hood.
Assembly and Mounting
Hood Mounting
1. Assemble the hood to the table using four 1/4” x 20 bolts (3/4” long) and lock washers. Mounting
brackets are fixed to the support legs as shown below.
Front Mounting Brackets Rear Mounting Brackets
2. Seal the hood base to unit using NS approved silicone rubber sealant.

Ventless Hood System Installation
6
3. Place the appliance shelf under the hood as shown below.
Particle/Odor Filter
1. Remove the filter from the plastic bag.
2. Open the filter door on the front of the unit by rotating the handle counter-clockwise.
3. Observing the “UP” arrows on the filter, with a hand at each front corner, carefully slide the filter
into the unit.
4. Close and latch the door.
Fire Damper
A UL Listed 165° fusible link must be installed in the damper assembly located at the top of the unit.
Install as follows:
1. Lift the damper.
2. Place the link on the damper hook.
3. Lower the damper while placing the link onto the stationary hook.

Ventless Hood System Installation
7
Air Deflector
Mount air deflector, as shown in the figure below, using two knurled screws (provided).
Fire Extinguishing System
In the event of an appliance fire, serious injury, property damage or death could
occur if any part of the appliance obstructs the spray nozzles. Ensure that lids
and/or other parts of the appliance do not obstruct the spray pattern of either
nozzle.
The fire extinguishing system components used in this hood have been
evaluated by U.L. in the course of their classification for use on this hood.
An authorized Range Guard distributor must install and activate the filter hood
fire extinguishing system. To locate an authorized Range Guard Distributor use
the following contact information:
Ronald Woodward
Technical Service Specialist
Badger ire Protection
4251 Seminole Trail
Charlottesville Va. 22911
Office: 800-446-3857 ext. 111
ax: 434-974-4113
Mobile: 434-981-0505

Ventless Hood System Installation
8
1. Mount the fire extinguisher control as follows:
a. When viewed from the front of the hood, mount the fire extinguisher control/cylinder plate to
right hand side of hood (see igure 1) when hood is mounted on left end of table or to left
side of hood (see igure 2) when hood is mounted on right end of table. Use (2) ¼-20x3/4”
bolts and lockwashers to secure plate to rear of hood frame.
b. Attach cylinder actuator and discharge fitting assembly cylinder.
c. Mount cylinder on bracket.
d. Attach 8” nipple, 17.5” nipple, 90° ells, and union/vent assembly as shown in igure 1 or
igure 2. It may be necessary to rotate the union and elbow 180° to attach to cylinder union.
e. Attach conduit lengths and corner pulleys to A+ control box as shown in igure 1 or igure 2
simultaneously routing cable per standard Range Guard procedures.
f. Route flexible conduit as shown to top of A+ control box.
g. Connect microswitch interlock to hood electrical wires per wiring diagram provided in this
manual. Refer to the electrical diagram included in this manual (see page 26).
2. Mount the Pull Station as follows:
a. Remove protective plastic from all parts.
b. Mount remote pull box to remote pull enclosure bottom using (2) ¼-20x ¾ bolts,
lockwashers, and nuts.
c. Mount remote pull mounting plate to side of table using hardware provided with table.
d. Refer to in igure 3 or igure 4. Attach remote pull enclosure bottom to inside of mounting
plate using (6) #10 sheetmetal screws.
e. Attach conduit lengths and corner pulleys to remote pull box as shown in igure 3 or igure 4
simultaneously routing cable per standard Range Guard procedures.
f. Attach remote pull enclosure top to mount plate and enclosure bottom using (8) #10
sheetmetal screws.
h. Mount remote pull cover plate. Refer to igure 5 for complete pull station mounting.

Ventless Hood System Installation
9
Figure

Ventless Hood System Installation
10
Figure 2

Ventless Hood System Installation
11
Figure 3. Right Side Pull Station Mounting

Ventless Hood System Installation
12
Figure 4. Left Side Pull Station Mounting

Ventless Hood System Installation
13
Figure 5. Complete Pull Station Mounting

Ventless Hood System Installation
14
3. If required, connect the provided fire extinguishing system contacts for remote signaling. Refer to
the electrical diagram included in this manual (see page 26).
4. Adjust the position of the two ADP appliance nozzles as depicted below.
5. Install two UL Listed; type “A”, 165° . fusible links (load rating 3-45 lbs.) in the two appliance
detector positions (one in front of the grease baffle, one behind the grease baffle).
FUSIBLE
LINKS

Ventless Hood System Installation
15
6. Reset control head. With control head NOT installed on cylinder, dry test system by activating the
remote pull.
7. Reset control head and activate system per Range Guard procedures.
8. Recheck installation procedure to insure that nothing has been overlooked.
Wiring
Electrocution, equipment failure or property damage could result if an unlicensed
electrician performs the electrical installation. Ensure that a licensed
electrician performs the electrical installation using appropriate materials
and construction practices which conform to the National Electric Code
and all local codes.
In the event of an appliance fire, serious injury, property damage or death could
occur if the appliance is powered from a source other than the hood. The cooking
appliance used under this hood MUST receive its input power from the hood. In
the event of a fire, the hood fire extinguishing system will automatically remove
power from the connected appliance.
The fire extinguishing system must be operative before the electrical system will
function.
Refer to the electrical diagram included in this manual (see page 26).
The hood may be connected to either a 208/120V or a 240/120V supply. The supply may be either 3
phase or 1 phase. The hood as supplied, is connected for single phase operation. When a three phase
supply is available, it can be internally reconnected for three phase operation to balance load. Refer to
the directions on the hood wiring diagram. (see page 26).
Connection to the hood electrical box can be made using either flexible conduit, or a cord/plug
combination. One-inch knockouts are provided in the top and the bottom of the electrical box. A ground
wire and a separate neutral wire MUST be provided for all connections. The minimum recommended wire
size is 8ga. The circuit protection device should be sized at 40 amperes. The hood/table system should
be restrained to avoid any stress on the conduit or cord connecting the appliance when the system is
moved for cleaning. Insure that cords or conduit are properly secured as to avoid any physical damage
from covers, edges, etc. when the unit is moved.
1. Connect incoming power as follows:
• or single-phase operation, connect incoming power to terminals L1 and L2 of the contactor.
Connect neutral and ground as shown in igure 6.
• or three-phase operation, connect incoming power to terminals L1, L2 and L3 of the
contactor. Reconnect second receptacle inside hood electrical box to T2 and T3 on 1CR.
Connect neutral and ground as shown in igure 6.
2. Insure that the fire extinguishing control box microswitch has been properly connected. Refer to
1g on page 8.

Ventless Hood System Installation
16
3. Place circuit breakers 1CB thru 4CB in the ON position.
Wiring may become damaged from wear if straight plugs are used. Appliances
must have right angle plugs to properly fit under receptacle cover.
4. Insert plug into receptacles located in the hood.
1 RECPT.
2 RECPT.
3 RECPT.
4 RECPT.
1FU
3FU
1CB
2CB
2FU
4FU
3CB
4CB

Ventless Hood System Installation
17
5. Install the cover over the appliance receptacles as shown.
6. Install rear cover on the back of the hood as shown. The cover installs on 4 posts located inside
the frame
Note: To remove the rear cover, lift and pull toward you.

Ventless Hood System Maintenance
18
Maintenance
Electrocution could occur if this unit is hosed down with water. This unit is NOT
designed for hose wash-down cleaning! Refer to scheduled maintenance below
for proper hood cleaning.
Electrocution could occur if power is not removed from this unit before servicing.
Remove power at disconnect or circuit breaker BEFORE servicing hood.
Scheduled Maintenance
Use the following table to help manage scheduled maintenance activities.
FREQUENCY PERFORMED BY PART ACTIVITY
Daily User Entire Hood Wipe unit down with a soft rag and mild
cleaning agent.
User Condensation
trough
Check condensation trough. Empty if
necessary.
User Grease Baffle Clean grease baffle. If necessary, refer
to the procedure in this manual for
cleaning the baffle.
Weekly User Particle/Odor ilter Inspect particle/odor filter. In low to
medium volume applications, the filter
may need replacement prior to the
indicating light turning on. This
condition will be evident by a strong
odor coming from the face of the filter.
If necessary, refer to the procedure in
this manual for replacing the filter.
Monthly User Door and ilter
Interlock
Check door and filter interlock
operation. The unit should not operate
with the front door open or either the
grease baffle or particle/odor filter
removed. Clean area between grease
baffle and particle/odor filter.
Injury from rotating fan blades could occur if power is not removed from this unit
before cleaning the blower section. Remove power at disconnect or circuit breaker
BEFORE cleaning the blower section.
3 Months User Blower Section Clean the blower section.
6 Months Authorized Service
agent
ire Extinguishing
System
Have the fire extinguishing system
inspected.