Black Box Auto-Sync ASTC3000 User manual

Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) • FREE technical Support 24/7: 724-746-5500 or fax 724-746-0746
Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 • Web site: www.blackbox.com • E-mail: [email protected]
Customer
Support
Information
It is recommended to use the Auto-Sync
Utility CD included with your clock. Install and
start the Utility. When the Utility opens it will
automatically perform a local network clock
search. When the clock appears in the list,
double-click on the discovered clock to Login
using a browser.
Skip to Step 6
NOTE:
With the Utility open, click on Help to open the
Guide.
NOTE: To simplify discovery, the PC & Auto-Sync Time
Clock should be on the same Subnet. You can use the
Settings screen to switch Domains. See User Guide.
With Internet Explorer (IE) & Bonjour®,
select View Explorer Bar Bonjour. Locate
and click on the discovered clock in the list of
devices on the left-hand side to connect for login.
The Auto-Sync Time Clocks will appear here.
NOTE:
Bonjour may need
to be downloaded & installed
as a plug-in.
With Safari select
Bookmarks
Show All Bookmarks.
Locate and click
on the discovered
Auto-Sync Time Clock
in the “Bookmarks”
to connect for login.
During power up, the clock will flash “boot”,
then sequentially display the complete IP address
twice, and show a normal display of date and time.
For example, an
IP = 192.168.57.106
would display
1st 192
2nd 168
3rd 57
4th 106
NOTE:
If the clock cannot connect
to the network it will flash 0.0.0.0 for the IP address.
Auto-SyncTime Clock Quick-Start Guide
Not included
on PoE model
Remove cover to install
included cable for Ethernet
connection
July 2010
ASTCRCB
ASTCRCG
ASTCRCR
ASTCKEY
ASTC3000
ASTC3000POE
ASTCBK
ASTCPOEK
Plug in the male RJ-45 Ethernet cable to a
network connection. Next, plug-in the AC adapter.
(No AC adapter is required with Power over
Ethernet [PoE] option).
NOTE: Port 5353 must be open for local service
discovery. Port 53 must be open for a wide area
service discovery.
NOTE:
F
Fo
or
r
P
Po
oE
E
M
Mo
od
de
el
l
t
th
he
e
c
co
ol
lo
on
n
o
on
n
t
th
he
e
d
di
is
sp
pl
la
ay
y
s
sh
ho
ou
ul
ld
d
b
be
e
f
fl
la
as
sh
hi
in
ng
g
t
to
o
i
in
nd
di
ic
ca
at
te
e
P
Po
oE
E
i
is
s
w
wo
or
rk
ki
in
ng
g
p
pr
ro
op
pe
er
rl
ly
y.
.
Remove the following contents from the box:
N
Ne
ex
xt
t
I
In
ns
se
er
rt
t
t
th
he
e
k
ke
ey
y
a
an
nd
d
t
tu
ur
rn
n
c
cl
lo
oc
ck
kw
wi
is
se
e
t
to
o
r
re
em
mo
ov
ve
e
t
th
he
e
c
co
ov
ve
er
r.
.
A
Af
ft
te
er
r
r
re
em
mo
ov
vi
in
ng
g
t
th
he
e
c
co
ov
ve
er
r,
,
l
li
if
ft
t
u
up
p
t
th
he
e
P
Pr
ri
in
nt
te
er
r
B
Bl
lo
oc
ck
k
(
(A
A)
)
a
an
nd
d
r
re
em
mo
ov
ve
e
t
th
he
e
P
Pa
ac
ck
ki
in
ng
g
S
Sp
pa
ac
ce
er
r
(
(B
B)
).
.
I
In
ns
se
er
rt
t
E
Et
th
he
er
rn
ne
et
t
c
ca
ab
bl
le
e.
.
F
Fo
or
r
P
Po
oE
E
M
Mo
od
de
el
l
c
co
on
nn
ne
ec
ct
t
t
th
he
e
b
ba
at
tt
te
er
r
y
y
p
p
a
ac
ck
k.
.
R
R
e
e
p
p
l
la
ac
ce
e
t
th
he
e
c
co
ov
ve
er
r
a
an
nd
d
l
lo
oc
ck
k.
.
1st
No AC power
required for PoE model
2nd
At the clock Login web page enter:
Username = Admin
Password = password
This can be changed later.
NOTE:
Only 1 user can be logged in and the login
times out after 5 minutes of no activity.
Internet
Ex
p
lorer
Safari
56
4
3
2
1
Included
Key

Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) • FREE technical Support 24/7: 724-746-5500 or fax 724-746-0746
Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 • Web site: www.blackbox.com • E-mail: [email protected]
Customer
Support
Information
For additional information, click on Help with the Utility open to launch the Auto-Sync Time Clock User Guide.
NOTE: For PoE models, leaving the Auto-Sync Time Clock unplugged from a PoE terminal or without power for more than 24
hours may create a problem with the clock starting up (you will see “low bat” briefly appear in the display). In this instance, the
clock should be started with the battery pack cable disconnected and the clock plugged into a PoE terminal.Wait until the clock
starts up, or displays the time, then reconnect the battery pack cable and it will charge. During this time, Amano recommends to
wait 24 hours before printing.
After login, the Auto-Sync Time Clock “Clock
Information” page will appear. Black Box
recommends creating a name and description.
Use the
Menu
Selections
on the left
of your
browser to
configure
the clock
in the
following
Steps.
If the default DNS Server configuration is not
acceptable or you do not have access to the
Internet, Black Box recommends defining the
DNS Servers to perform time sync and discovery.
Click on the
DNS Servers
link on the
left under
Time Sync
to define
your DNS
Server(s).
NOTE:
See the User Guide for more detailed DNS
Server setup information. See router Port NOTE in
Step 2.
If the default Time Servers are not acceptable
or you do not have access to the Internet, Black
Box recommends defining the Time Servers
(including Internal Time Servers) for time sync.
Please define:
Name
Host Name / IP Address
Enabled
Order of use
Click on the Time Servers
link on the left under
Time Sync and from the
Time Server List click the
Add button to create a
new Time Server. Click the “Test Time Sync”
button to test the Time Server connection.
NOTE: Port 123 must be open to use time
servers.
Black Box recommends defining
Schedules for time sync to maintain your
clock’s time sync. Your clock comes with 2
default schedules that can be edited. Please
define:
Name & Type
Start Date & Time
Daily or Weekly Frequency
Click on the
Schedules
link on the left
under Scheduling
to define time sync
frequency.
Also, you can define
Backup & Reports
schedules here.
If E-mail notification and SNMP Traps are
desired, Black Box recommends defining your E-
mail and SNMP Trap settings.
NOTE: E-mail notification must also be checked
enabled.
Click on the E-Mail link on the left under
Notification for e-mail. Click on the SNMP Trap
link on the left to define SNMP Traps.
NOTE: Port 25 must be open to use E-mail
notification. Port 162 must be open to use SNMP
Traps.
Black Box recommends to Backup the clock
transaction & configuration settings, please define
your Utilities Settings for Backup, Restore and
Report functions.
Click on the Settings
link under Utilities to
define an FTP Server
for these functions.
NOTE: Port 21 must
be open for FTP.
Click on the
Backup/Restore
or Reports link
to perform
these functions.
11 12
10
9
8
7
Menu
Selections
AJ
R
-198900A
Other manuals for Auto-Sync ASTC3000
1
This manual suits for next models
7