7
Installation
3. Fit the gas regulator supplied, into the gas supply line as close to the appliance as possible.
NOTE: The gas pressure regulator provided with this appliance is convertible between Natural Gas
and LPG as per the ‘Gas Conversion Section’ in this manual.
Ensure the regulator is converted to the correct gas type that the appliance will operate on.
The regulator outlet pressure is fixed ex-factory for the gas type that the
regulator is converted to and it is NOT to be adjusted.
The regulator connections are 1/2" BSP female.
The connection to the appliance is 1/2" BSP male.
(Refer to the “Specifications” section for the gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to the individual appliance supply line.
4. Correctly locate the griddle toaster into its final operating position and using a spirit level, adjust the
legs so that the appliance is level and at the correct height.
5. Connect the gas supply to the appliance. A suitable jointing compound which resists the breakdown
action of LPG must be used on every gas line connection, unless compression fittings are used.
6. Check all gas connections for leakages using soapy water or other gas detecting equipment.
7. Check that the gas operating pressure is as shown in the ‘Specifications’ section.
NOTE: The operating pressure to be measured at
the manifold test point and with all burners
operating at the ‘High Flame’ setting.
8. Turn off the mains gas supply and bleed the gas
out of the appliance gas lines.
9. Turn on the gas supply and the appliance.
10. Verify the operating pressure remains correct.
Commissioning
1. Before leaving the new installation;
a. Check the following functions in accordance with the operating instructions specified in the
‘Operation’ section of this manual.
• Light the Pilot Burner.
• Light the Main Burners.
• Check the Low Fire burner operation.
• Check the High Fire burner operation.
b. Ensure that the operator has been instructed in the areas of correct lighting, operation, and
shutdown procedure for the appliance.
2. This manual must be kept by the owner for future reference, and a record of
Date of Purchase,
Date of Installation
and
Serial Number of Appliance
recorded and kept with this manual.
(These details can be found on the Rating Plate attached to the R/H side panel (refer to
the ‘Gas Connection’ section).
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off the
gas supply and contact the supplier of this appliance.
WARNING:
DONOT USE ANAKED FLAME TO CHECK FOR GAS LEAKAGES.
Pressure Test Point Low Fire Adjustment Fig 2